NPNhu Vinh Tuyen Pham

Nhu Vinh Tuyen Pham

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nhu Vinh Tuyen Pham has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnostic Accuracy of Cybersight AI for Glaucoma Detection: Sensitivity, Specificity, and ROC Analysis

    by Nha Uyen Phan, Trong Van Pham, Kim Thanh Doan, Le Phuc Hoang, Nhu Vinh Tuyen Pham, Minh Tuan Nguyen, Quoc Tung Mai, Nicolas Jaccard, Nathan Congdon

    Glaucoma is a chronic, progressive optic neuropathy and a leading cause of irreversible blindness worldwide. Early detection is crucial but is often limited by nonspecific clinical signs and the need for specialist expertise. Artificial intelligence (AI), particularly deep learning, has shown promise for glaucoma detection from ophthalmic images. This study independently validated an existing third-party AI tool, Cybersight AI, powered by the Visulytix Pegasus engine, for detecting primary glaucoma. No new algorithm was developed or proposed. A cross-sectional diagnostic accuracy study was conducted on 229 eyes from 121 patients, including 133 eyes with primary glaucoma and 96 controls, at Hue Central Hospital between December 2024 and September 2025. Fundus photographs were analyzed using the Cybersight AI platform, which estimated the vertical cup-to-disc ratio and generated a binary glaucoma referral recommendation. AI outputs were compared with diagnoses established by ophthalmologists using an expert multimodal clinical reference standard. Diagnostic performance was assessed using sensitivity, specificity, positive and negative predictive values, and the area under the receiver operating characteristic curve (AUC). At its default operating point, Cybersight AI achieved 51.9% sensitivity (95% CI 43.5–60.2) and 90.6% specificity (95% CI 83.1–95.0), with an AUC of 0.744 (95% CI 0.682–0.807). Positive and negative predictive values were 88.5% and 57.6%, respectively. The Youden-optimal cut-off was 10%, yielding 60.9% sensitivity and 85.4% specificity. Cybersight AI demonstrated moderate discrimination, high specificity, and modest sensitivity at its default binary setting in this Vietnamese tertiary-care cohort. It may serve as a screening or triage adjunct, although context-specific thresholding and further external validation are required before broad clinical deployment. Limitations include the single-center convenience sample, within-patient clustering, and comparison of a fundus-only index test against a multimodal reference standard. Future studies should prioritize multicenter validation in Vietnamese settings and comparison with expert fundus assessment alone.

  • Open Access

    Đánh giá kết quả điều trị glôcôm góc mở bằng laser tạo hình vùng bè chọn lọc tại Bệnh viện Trung ương Huế

    by Phạm Như Vĩnh Tuyên, Lê Ngọc Hải An, Hà Giang, Phan Nhã Uyên, Hoàng Hòa Nhiên Trần

    Mục tiêu: Đánh giá kết quả hạ nhãn áp và mức độ an toàn của phương pháp tạo hình vùng bè chọn lọc bằng laser (SLT) trong điều trị glôcôm góc mở. Đối tượng, phương pháp: Nghiên cứu mô tả tiến cứu, có can thiệp lâm sàng, không đối chứng. Gồm 71 mắt trên 41 bệnh nhân glôcôm góc mở được điều trị laser tạo hình vùng bè chọn lọc tại Trung tâm Mắt, Bệnh viện Trung ương Huế từ tháng 1/2024 đến tháng 9/2025. Theo dõi sau điều trị 1 tuần, 1 tháng, 3 tháng. Kết quả: Nhãn áp trung bình tại tất cả các thời điểm theo dõi đều giảm có ý nghĩa thống kê so với trước điều trị. Tại thời điểm 3 tháng sau điều trị, có 62/71 (87,3%) mắt có đáp ứng điều trị. Các biến chứng xuất hiện thoáng qua, không đáng kể. Biến chứng gặp nhiều nhất là biến chứng nhức mắt (11,3%). Kết luận: Phương pháp tạo hình vùng bè chọn lọc bằng laser có tính an toàn và có hiệu quả hạ nhãn áp cao trong điều trị glocom góc mở.