Sanjitpal S. Gill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sanjitpal S. Gill has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Sahil Garg
The Steadman Philippon Research Institute, Vail, Colorado
6 shared publications - Arianna K. Gill
The Steadman Philippon Research Institute, Vail, Colorado
3 shared publications - Patrick Young
The Steadman Clinic and Steadman Philippon Research Institute
3 shared publications - Christopher Franquemont
Loma Linda University School of Medicine, Loma Linda, California
2 shared publications - Kyle Jamar
Department of Orthopedics, University of Colorado School of Medicine, Aurora, CO 80045, USA
2 shared publications - Michael A. Gallizzi
The Steadman Philippon Research Institute, Vail, Colorado
2 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 28
Determinants of intraoperative radiation during single-level tubular lumbar decompression
- 8 October 2026
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 28
Open AccessDeterminants of intraoperative radiation during single-level tubular lumbar decompression
- Open Access
- 1 October 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (4)
Program-Reported Characteristics of Orthopaedic Surgery Residency Programs
Introduction: Orthopaedic Surgery remains one of the most competitive specialties. The Orthopaedic Residency Information Network (ORIN), maintained by the American Orthopaedic Association, provides publicly reported program-level data on Orthopaedic Surgery residencies. We therefore aimed to examine what ORIN reveals about reported variation in resident characteristics across Orthopaedic Surgery residency programs of different types. Examined variables included median USMLE Step 2 scores, away rotation percentage (the share of a program's current residents who completed a visiting rotation there before matching), and Comprehensive Osteopathic Medical Licensing Examination of the United States (COMLEX-USA) reporting across academic, community, and hybrid programs. Methods: A cross-sectional analysis of ORIN (orin.aoassn.org, March 2026) included programs with data updated on or after January 1, 2024, that self-identified as academic, community, or hybrid. Of 184 programs, 34 were excluded for nonstandard classifications or outdated data, yielding 150 programs (109 academic, 22 community, 19 hybrid). Results: Community and hybrid programs reported COMLEX-USA more often than academic programs (32% and 16% vs. 3%, p < 0.001). Median Step 2 scores did not differ across program types (p = 0.152). When dichotomized at 40% away rotation percentage, 62% of community vs 29% of academic programs fell below this threshold (p = 0.029). Higher away rotation percentages were associated with more rotator interviews (rho = 0.361, p < 0.001). COMLEX-reporting programs had higher away rotation percentages (70.9% vs. 46.5%, p = 0.005) and rotator-to-resident ratios (1.60 vs. 0.91, p < 0.001). Conclusions: This analysis reveals variation in reported resident characteristics across program types. Reported Step 2 differences across program types and away rotation quartiles were small, within the USMLE standard error of difference, and unlikely to be practically meaningful. Programs with more current residents who rotated there as visiting students reported more rotator interviews. Community and hybrid programs reported COMLEX-USA more often, identifying programs potentially more receptive to osteopathic applicants. Findings reflect associations, not program-applied criteria, and may inform application strategy.
- 1 October 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (4)
Open AccessProgram-Reported Characteristics of Orthopaedic Surgery Residency Programs
Introduction: Orthopaedic Surgery remains one of the most competitive specialties. The Orthopaedic Residency Information Network (ORIN), maintained by the American Orthopaedic Association, provides publicly reported program-level data on Orthopaedic Surgery residencies. We therefore aimed to examine what ORIN reveals about reported variation in resident characteristics across Orthopaedic Surgery residency programs of different types. Examined variables included median USMLE Step 2 scores, away rotation percentage (the share of a program's current residents who completed a visiting rotation there before matching), and Comprehensive Osteopathic Medical Licensing Examination of the United States (COMLEX-USA) reporting across academic, community, and hybrid programs. Methods: A cross-sectional analysis of ORIN (orin.aoassn.org, March 2026) included programs with data updated on or after January 1, 2024, that self-identified as academic, community, or hybrid. Of 184 programs, 34 were excluded for nonstandard classifications or outdated data, yielding 150 programs (109 academic, 22 community, 19 hybrid). Results: Community and hybrid programs reported COMLEX-USA more often than academic programs (32% and 16% vs. 3%, p < 0.001). Median Step 2 scores did not differ across program types (p = 0.152). When dichotomized at 40% away rotation percentage, 62% of community vs 29% of academic programs fell below this threshold (p = 0.029). Higher away rotation percentages were associated with more rotator interviews (rho = 0.361, p < 0.001). COMLEX-reporting programs had higher away rotation percentages (70.9% vs. 46.5%, p = 0.005) and rotator-to-resident ratios (1.60 vs. 0.91, p < 0.001). Conclusions: This analysis reveals variation in reported resident characteristics across program types. Reported Step 2 differences across program types and away rotation quartiles were small, within the USMLE standard error of difference, and unlikely to be practically meaningful. Programs with more current residents who rotated there as visiting students reported more rotator interviews. Community and hybrid programs reported COMLEX-USA more often, identifying programs potentially more receptive to osteopathic applicants. Findings reflect associations, not program-applied criteria, and may inform application strategy.
- 6 August 2026
- Published by Elsevier in Journal of Surgical Education
- Vol. 83 (10)
Rising Costs Without Rising Match Rates: Orthopedic Surgery Application Spending Before and After the USMLE Step 1 Pass/Fail Transition
- 6 August 2026
- Published by Elsevier in Journal of Surgical Education
- Vol. 83 (10)
Rising Costs Without Rising Match Rates: Orthopedic Surgery Application Spending Before and After the USMLE Step 1 Pass/Fail Transition
- 25 June 2026
- Published by Springer Nature
- p. 247-254
Clinical Impact of Muscle-Sparing Wiltse Transforaminal Lumbar Interbody and Fusion
- 25 June 2026
- Published by Springer Nature
- p. 247-254
Clinical Impact of Muscle-Sparing Wiltse Transforaminal Lumbar Interbody and Fusion
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Exploring the Orthopaedic Surgery Match
Introduction: Orthopaedic Surgery remains one of the most competitive medical specialties to successfully match into. Historically, the United States Medical Licensing Examination Step 1 score was a major determinant of match success. Since its conversion to pass/fail status in January 2022, uncertainty has emerged regarding how programs mentor and advise applicants. The purpose of this study was to examine the changes in Orthopaedic Surgery applicant characteristics before the transition from a scored examination (2017-2022) to a pass/fail examination (2023-2025). Methods: The authors accessed the Texas Seeking Transparency in Application to Residency survey database, which contains survey information from graduating medical students nationwide regarding residency application characteristics. Characteristics of matched versus unmatched applicants between 2017 to 2022 and 2023 to 2025 were compared. Results: A total of 1,652 Orthopaedic Surgery applicants responded to the survey from 2017 to 2025 (data collected in May 2025). Since the incorporation of a pass/fail Step 1, Step 2 scores and research productivity has increased, volunteerism has decreased, and other academic metrics have remained unchanged. Conclusions: Applicants demonstrated shifts in characteristics without a corresponding change in match rates. From 2023 to 2025, applicants bolstered Step 2 performance and research output as primary differentiators in the absence of a numerical Step 1 score. Traditional academic markers such as class rank, clerkship performance, and Alpha Omega Alpha membership remained stable, while volunteer and leadership involvement declined moderately over the same period. These findings provide evidence-based guidance for navigating the Orthopaedic Surgery selection process in the postnumerical Step 1 era.
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Open AccessExploring the Orthopaedic Surgery Match
Introduction: Orthopaedic Surgery remains one of the most competitive medical specialties to successfully match into. Historically, the United States Medical Licensing Examination Step 1 score was a major determinant of match success. Since its conversion to pass/fail status in January 2022, uncertainty has emerged regarding how programs mentor and advise applicants. The purpose of this study was to examine the changes in Orthopaedic Surgery applicant characteristics before the transition from a scored examination (2017-2022) to a pass/fail examination (2023-2025). Methods: The authors accessed the Texas Seeking Transparency in Application to Residency survey database, which contains survey information from graduating medical students nationwide regarding residency application characteristics. Characteristics of matched versus unmatched applicants between 2017 to 2022 and 2023 to 2025 were compared. Results: A total of 1,652 Orthopaedic Surgery applicants responded to the survey from 2017 to 2025 (data collected in May 2025). Since the incorporation of a pass/fail Step 1, Step 2 scores and research productivity has increased, volunteerism has decreased, and other academic metrics have remained unchanged. Conclusions: Applicants demonstrated shifts in characteristics without a corresponding change in match rates. From 2023 to 2025, applicants bolstered Step 2 performance and research output as primary differentiators in the absence of a numerical Step 1 score. Traditional academic markers such as class rank, clerkship performance, and Alpha Omega Alpha membership remained stable, while volunteer and leadership involvement declined moderately over the same period. These findings provide evidence-based guidance for navigating the Orthopaedic Surgery selection process in the postnumerical Step 1 era.
- Open Access
- 12 March 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (3) , 143
Three-Dimensional Printing of a Spinal Interbody: Design Principles, Biomaterials, and Translational Considerations
Background: Interbody spinal fusion is a common surgical treatment for degenerative, traumatic, and deformity-related spinal pathologies. Despite advances in cage geometry and fixation strategies that improve alignment and early stability, reliable fusion remains limited by the mechanical and biological constraints of conventional interbody implant materials. Traditional titanium and polymer-based cages often fail to optimally balance load sharing, osteointegration, and biological activity within the mechanically demanding interbody environment. This narrative review examines the development and translational potential of 3D-printed interbody fusion devices, with emphasis on how additive manufacturing enables the integration of mechanical performance with biologically active scaffold design. Methods: A thorough literature review was performed to evaluate the evolution, design principles, material properties, and translational outcomes of three-dimensional (3D)-printed interbody fusion devices. Results: Additive manufacturing enables precise control over implant architecture, allowing for the fabrication of porous, lattice-based cages with tunable stiffness, optimized load sharing, and enhanced bone–implant integration. Preclinical and early clinical studies suggest that 3D-printed porous titanium cages may reduce subsidence, promote osteointegration, and improve fusion-related outcomes compared with conventional designs. Emerging evidence indicates that scaffold porosity, surface microtopography, and bioactive coatings influence macrophage polarization, angiogenesis, and osteogenic signaling. Polymeric and composite constructs, particularly hybrid designs incorporating surface functionalization, represent promising adjuncts, though clinical evidence remains limited. Conclusions: Three-dimensional printing represents a paradigm shift in interbody fusion device design. Continued translational research and longer-term clinical follow-up are required to validate efficacy and guide widespread clinical adoption.
- 12 March 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (3) , 143
Open AccessThree-Dimensional Printing of a Spinal Interbody: Design Principles, Biomaterials, and Translational Considerations
Background: Interbody spinal fusion is a common surgical treatment for degenerative, traumatic, and deformity-related spinal pathologies. Despite advances in cage geometry and fixation strategies that improve alignment and early stability, reliable fusion remains limited by the mechanical and biological constraints of conventional interbody implant materials. Traditional titanium and polymer-based cages often fail to optimally balance load sharing, osteointegration, and biological activity within the mechanically demanding interbody environment. This narrative review examines the development and translational potential of 3D-printed interbody fusion devices, with emphasis on how additive manufacturing enables the integration of mechanical performance with biologically active scaffold design. Methods: A thorough literature review was performed to evaluate the evolution, design principles, material properties, and translational outcomes of three-dimensional (3D)-printed interbody fusion devices. Results: Additive manufacturing enables precise control over implant architecture, allowing for the fabrication of porous, lattice-based cages with tunable stiffness, optimized load sharing, and enhanced bone–implant integration. Preclinical and early clinical studies suggest that 3D-printed porous titanium cages may reduce subsidence, promote osteointegration, and improve fusion-related outcomes compared with conventional designs. Emerging evidence indicates that scaffold porosity, surface microtopography, and bioactive coatings influence macrophage polarization, angiogenesis, and osteogenic signaling. Polymeric and composite constructs, particularly hybrid designs incorporating surface functionalization, represent promising adjuncts, though clinical evidence remains limited. Conclusions: Three-dimensional printing represents a paradigm shift in interbody fusion device design. Continued translational research and longer-term clinical follow-up are required to validate efficacy and guide widespread clinical adoption.