Giulio Russo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Giulio Russo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cristina Baglivo
Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy
1 shared publication - Gianluca Falcicchia Ferrara
Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy
1 shared publication - Irene Petrosillo
Department of Biological and Environmental Sciences and Technologies, University of Salento, 73100 Lecce, Italy
1 shared publication - Marina Bonomolo
Department of Engineering, University of Palermo, 90128 Palermo, Italy
1 shared publication - Michele Spagnolo
Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy
1 shared publication - Paolo Maria Congedo
Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy
1 shared publication
Latest Publications
- Open Access
Preliminary Experimental Investigation of the Performance of a Horizontal Air-Ground Heat Exchanger Integrated with Peltier Cells—The AIRcon.WATER Project
This work experimentally investigates the behavior of a new indoor air conditioning system based on the application of Peltier cells in a Horizontal Air–Ground Heat Exchanger (HAGHE). To this end, a laboratory-scale prototype focusing exclusively on the terminal section of the system was developed and tested under controlled conditions. A series of configurations was tested, each representing an evolution of the previous one. The results highlight the strong dependence of system performance on airflow velocity, applied voltage, and heat dissipation effectiveness, demonstrating both the potential and the critical limitations of the proposed configurations. The most promising results were obtained in the advanced (fourth and fifth) configurations, yielding average temperature increases of approximately +1.9 °C on the hot flow and decreases ranging from −1.0 °C to −1.7 °C on the cold flow at moderate total voltages (40–50 V) and higher airflow velocities (0.5–0.6 m/s). In line with the principles of the circular economy, the prototype was constructed using recycled materials, including plastic pipes and Peltier cells recovered from discarded devices.
Open AccessPreliminary Experimental Investigation of the Performance of a Horizontal Air-Ground Heat Exchanger Integrated with Peltier Cells—The AIRcon.WATER Project
This work experimentally investigates the behavior of a new indoor air conditioning system based on the application of Peltier cells in a Horizontal Air–Ground Heat Exchanger (HAGHE). To this end, a laboratory-scale prototype focusing exclusively on the terminal section of the system was developed and tested under controlled conditions. A series of configurations was tested, each representing an evolution of the previous one. The results highlight the strong dependence of system performance on airflow velocity, applied voltage, and heat dissipation effectiveness, demonstrating both the potential and the critical limitations of the proposed configurations. The most promising results were obtained in the advanced (fourth and fifth) configurations, yielding average temperature increases of approximately +1.9 °C on the hot flow and decreases ranging from −1.0 °C to −1.7 °C on the cold flow at moderate total voltages (40–50 V) and higher airflow velocities (0.5–0.6 m/s). In line with the principles of the circular economy, the prototype was constructed using recycled materials, including plastic pipes and Peltier cells recovered from discarded devices.