YHYanqi Hou

Yanqi Hou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yanqi Hou has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Improved Fixed-Frequency Control Method for Inverter-Dominated Islanded Microgrids Under Various Operating Conditions

    by Kuan Li, Yanqi Hou, Yudun Li, Kongming Sun, Tongyu Liu

    Synchronized fixed-frequency current control (SFFC) enables inverter-dominated islanded microgrids to regulate power without relying on frequency deviations. However, conventional SFFC may exhibit power oscillations when battery storage systems (BSSs) transition from discharging to charging, while unbalanced and nonlinear loads can degrade voltage quality. To address these challenges, this paper proposes an improved SFFC scheme integrating power decoupling, multi-frequency voltage compensation, and current-capacity coordination. First, the mechanism of power oscillations during BSS discharging-to-charging transitions is analyzed, and a voltage-vector-oriented controller is developed to decouple active- and reactive-power regulation. Second, the effects of negative-sequence and harmonic currents on voltage distortion are analyzed while considering the inverter equivalent impedance. Accordingly, a compensation method combining notch and low-pass filters is developed to extract and compensate for the fundamental negative-sequence and selected harmonic components. Third, a residual-current-capacity-based allocation strategy is developed to coordinate reactive-power support, negative-sequence voltage compensation, and harmonic suppression within inverter current limits. Furthermore, a satellite-synchronized mode-transition strategy is incorporated to facilitate transitions between grid-connected and islanded operation. Simulation and experimental results demonstrate improved power regulation and voltage quality under different operating conditions. Specifically, the experimental line-voltage unbalance index decreases from 3.83% to 1.64%, while the line-voltage total harmonic distortion decreases from 4.89% to 1.98%. Stable BSS charging and discharging operation and grid-connected-to-islanded transitions are also experimentally demonstrated.

  • Open Access

    Two-Layer Collaborative Optimization for Multi-Period Fault Recovery in Active Distribution Networks with Fast Decomposition

    by Yanqi Hou, Kuan Li, Yudun Li, Kongming Sun

    With the increasing integration of distributed generation, energy storage, and flexible loads, active distribution networks have gained multiple fault-recovery options, including network reconfiguration, islanded operation, and coordinated source–load regulation. However, existing studies often lack an effective link between system-level restoration decisions and resource-level execution. To address this issue, this paper proposes a two-layer collaborative optimization method for multi-period fault recovery with fast decomposition. The upper layer develops a multi-period restoration model that jointly optimizes network reconfiguration, load restoration targets, and fault repair sequences, with the objectives of minimizing load loss and recovery cost while maximizing continuous power-supply duration. The model incorporates load priorities, switch operations, distributed generation, energy-storage states, flexible-load response, main-grid support, and inter-period coupling constraints. Based on the restoration targets generated by the upper layer, the lower layer applies a fast sort-and-fill decomposition strategy to allocate regulation demands among photovoltaic generation, wind power, energy storage systems, flexible loads, and main-grid support, thereby forming a closed-loop coordination mechanism between restoration planning and resource execution. The proposed method is validated on a modified IEEE 33-bus active distribution network under multi-period fault scenarios. Results show that the load restoration rate is 88.78% in Period 1 and reaches 100% from Period 2 onward. Compared with static restoration, unserved energy decreases from 4.6896 MWh to 0.3113 MWh, while restored energy increases from 8.2505 MWh to 12.6288 MWh. Over 1000 randomized feasible operating points, the maximum absolute objective gap between the proposed sort-and-fill procedure and direct LP re-optimization is 7.55×10−14%, and the maximum power-balance error is 2.73×10−12 kW. These results demonstrate that the proposed method improves restoration effectiveness while reproducing the exact lower-layer LP solution within numerical precision.

  • Open Access

    Analysis of High-Frequency Oscillation Propagation Path Based on Branch High-Frequency Power Distribution

    by Yudun Li, Yanqi Hou, Kai Liu, Zheng Xu, Shilong Shu, Yiping Yu

    While the generation mechanisms of high-frequency oscillations caused by voltage source converter-based high-voltage direct current (VSC-HVDC) systems have been widely investigated, their propagation paths and spatial influence within the power grid remain largely unexplored. To address this critical gap, this paper proposes a novel oscillation propagation analysis method based on branch high-frequency active power distribution. First, from the perspective of equivalent impedance, the mechanism of high-frequency oscillation caused by the VSC-HVDC system in a single-machine system is elaborated. Then, mathematical modeling and theoretical derivations reveal that synchronous generators primarily act as passive impedances at high frequencies and that transmission lines significantly distort high-frequency voltage and current amplitudes. Crucially, high-frequency active power remains inherently stable and immune to these line distortion effects. Building upon these characteristics, an instantaneous power calculation method using broadband measurement data is derived to trace the propagation path. Comprehensive case studies using a 4-machine 2-area system and the New England 10-machine 39-bus system demonstrate that the proposed method can accurately map actual physical propagation paths, evaluate an oscillation’s influence range, and reliably locate a high-frequency oscillation’s source.