Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Montserrat Mancera-Arteu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Estela Giménez

    Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028 Barcelona, Spain

    8 shared publications
  • Victoria Sanz-Nebot

    Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, Martí I Franquès 1-11, 08028, Barcelona, Spain

    5 shared publications
  • Victoria Sanz-Nebot

    Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028 Barcelona, Spain

    5 shared publications
  • Estela Giménez

    4 shared publications
  • Oumaima El Ouahabi

    Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, Martí I Franquès 1-11, 08028, Barcelona, Spain

    4 shared publications
  • Victòria Sanz-Nebot

    Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028 Barcelona, Spain

    4 shared publications

Latest Publications

  • Open Access

    Glycopeptide-based classification of erythropoietin biopharmaceuticals by microseparation techniques coupled to mass spectrometry and multivariate analysis

    by Helena Tejero, Montserrat Mancera-Arteu, Laura Pont, Fernando Benavente, Estela Giménez

  • Open Access

    Encapsulation efficiency determination methods for the analysis of different antigenic peptides within phosphatidylserine-liposomes

    by Irene Latorre, Montserrat Mancera-Arteu, Oumaima El Ouahabi, Míriam Salvadó, Sílvia Rodríguez-Vidal, Victoria Sanz-Nebot

    The prevalence of autoimmune diseases (AIDs) is increasing and persists in individuals of all ages as reported by Pisetsky ( Nat Rev Nephrol , 2023). Only palliative treatments are currently available as the development of a treatment that selectively eliminates the immune system autoreaction, without affecting its normal functioning, is not an easy task. In this regard, an innovative strategy based on phosphatidylserine-liposomes (PS-Liposomes) loaded with the autoantigenic peptide that triggers the autoimmune attack has demonstrated efficacy in different AIDs as described by Almenara-Fuentes et al. ( Nanomedicine 48, 2023) and Pujol-Autonell et al. ( PLoS One 10, 2015). Encapsulation efficiency (EE) determination in liposomal therapeutic formulations is considered one of the most important attributes, as the encapsulated drug concentration is usually related to the treatment’s effectiveness. In this regard, several methods have been described in the literature for the determination of specific peptides within liposomes. However, the described methodologies cannot usually be applied to other peptides with different properties. In this study, peptides with different lengths and physicochemical properties encapsulated in PS-Liposome formulations were used as models to evaluate several methods for both free and total antigen quantification. Different approaches for liposome lysis and subsequent total or encapsulated antigen quantification were studied. On the other hand, a comprehensive comparison of different centrifugal filters and an ultracentrifugation method was performed for free antigen determination. Identification and quantification of the autoantigenic peptides were performed by reversed-phase high-performance liquid chromatography with ultraviolet detection (RP-HPLC-UV). Results obtained for direct and indirect EE determinations were compared for PS-Liposome formulations, and the best conditions for each peptide were selected. Graphical Abstract

  • Open Access

    SEC-based isolation of phosphatidylserine-liposomes from biological samples for preclinical studies

    by Oumaima El Ouahabi, Montserrat Mancera-Arteu, Ángeles López-Godoy, Irene Latorre, Míriam Salvadó, Bruna Barneda-Zahonero, Sílvia Rodríguez-Vidal, Victoria Sanz-Nebot

    Autoimmune diseases represent a significant clinical challenge due to their high prevalence, chronic progression, and profound impact on patients’ quality of life. Despite advances in understanding their pathophysiological mechanisms, in most cases, only palliative treatments are available. In this regard, a novel therapeutic approach is under development, using phosphatidylserine-liposomes (PS-Liposomes) encapsulating specific antigenic peptides that trigger the autoimmune attack. By varying the encapsulated antigen, this method offers the potential to treat different autoimmune diseases. The development of robust bioanalytical methods to characterize PS-Liposomes in biological fluids is of great importance to evaluate their efficacy and safety in preclinical trials. This presents a significant challenge due to the presence of extracellular vesicles and proteins in blood with similar size and composition to PS-Liposomes. In this study, size exclusion chromatography (SEC) was assessed for the isolation of PS-Liposomes encapsulating acetylcholine receptor peptide (AChR), intended for myasthenia gravis treatment, from minipig serum samples. A home-packed column filled with Sepharose 2B-CL resin and two commercial columns with agarose resin (qEV 35 nm and qEV 70 nm) were tested by using fluorescently labelled PS-Liposomes. Fractions containing PS-Liposomes were monitored by flow cytometry and qEV columns were selected for further experiments. For PS-liposome preconcentration of the obtained fractions, two different methodologies were also evaluated (Centrisart filters and qEV kit). Lipid and antigenic peptide recoveries obtained for each method were determined by HPLC-ELSD and HPLC-MS, and the optimum isolation and preconcentration approach was selected. Finally, the established methodology was successfully applied to spiked minipig serum with unlabelled PS-Liposomes, and the preservation of structural integrity after isolation was demonstrated by nanoparticle tracking analysis (NTA) and scanning electron microscopy (SEM). Graphical abstract

  • Open Access

    Rapid and simple dual extraction for the analysis of lipids and autoantigenic peptides within phosphatidylserine-liposomes

    by Oumaima El Ouahabi, Montserrat Mancera-Arteu, Irene Latorre, Míriam Salvadó, Sílvia Rodríguez-Vidal, Victoria Sanz-Nebot


  • Open Access

    Targeting macrophages with phosphatidylserine-rich liposomes as a potential antigen-specific immunotherapy for type 1 diabetes

    by Ivan Garcia-Loza, David Perna-Barrull, Eva Aguilera, Lidia Almenara-Fuentes, Laia Gomez-Muñoz, Daniela Greco, Maria Vila, Miriam Salvado, Montserrat Mancera-Arteu, Michael W. Olszowy, et al.


  • Open Access

    Sensitive Analysis of Recombinant Human Erythropoietin Glycopeptides by On-Line Phenylboronic Acid Solid-Phase Extraction Capillary Electrophoresis Mass Spectrometry

    by Montserrat Mancera-Arteu, Fernando Benavente, Victoria Sanz-Nebot, Estela Giménez

    In this study, several chromatographic sorbents: porous graphitic carbon (PGC), aminopropyl hydrophilic interaction (aminopropyl-HILIC), and phenylboronic acid (PBA) were assessed for the analysis of glycopeptides by on-line solid-phase extraction capillary electrophoresis mass spectrometry (SPE-CE-MS). As the PBA sorbent provided the most promising results, a PBA-SPE-CE-MS method was developed for the selective and sensitive preconcentration of glycopeptides from enzymatic digests of glycoproteins. Recombinant human erythropoietin (rhEPO) was selected as the model glycoprotein and subjected to enzymatic digestion with several proteases. The tryptic O126 and N83 glycopeptides from rhEPO were targeted to optimize the methodology. Under the optimized conditions, intraday precision, linearity, limits of detection (LODs), and microcartridge lifetime were evaluated, obtaining improved results compared to that from a previously reported TiO2-SPE-CE-MS method, especially for LODs of N-glycopeptides (up to 500 times lower than by CE-MS and up to 200 times lower than by TiO2-SPE-CE-MS). Moreover, rhEPO Glu-C digests were also analyzed by PBA-SPE-CE-MS to better characterize N24 and N38 glycopeptides. Finally, the established method was used to analyze two rhEPO products (EPOCIM and NeuroEPO plus), demonstrating its applicability in biopharmaceutical analysis. The sensitivity of the proposed PBA-SPE-CE-MS method improves the existing CE-MS methodologies for glycopeptide analysis and shows a great potential in glycoprotein analysis to deeply characterize protein glycosites even at low concentrations of the protein digest.


  • Open Access

    Determination of Sialic Acid Isomers from Released N-Glycans Using Ion Mobility Spectrometry

    by Christian Manz, Montserrat Mancera-Arteu, Andreas Zappe, Emeline Hanozin, Lukasz Polewski, Estela Giménez, Victoria Sanz-Nebot, Kevin Pagel

    Complex carbohydrates are ubiquitous in nature and represent one of the major classes of biopolymers. They can exhibit highly diverse structures with multiple branched sites as well as a complex regio- and stereochemistry. A common way to analytically address this complexity is liquid chromatography (LC) in combination with mass spectrometry (MS). However, MS-based detection often does not provide sufficient information to distinguish glycan isomers. Ion mobility-mass spectrometry (IM-MS)─a technique that separates ions based on their size, charge, and shape─has recently shown great potential to solve this problem by identifying characteristic isomeric glycan features such as the sialylation and fucosylation pattern. However, while both LC-MS and IM-MS have clearly proven their individual capabilities for glycan analysis, attempts to combine both methods into a consistent workflow are lacking. Here, we close this gap and combine hydrophilic interaction liquid chromatography (HILIC) with IM-MS to analyze the glycan structures released from human alpha-1-acid glycoprotein (hAGP). HILIC separates the crude mixture of highly sialylated multi-antennary glycans, MS provides information on glycan composition, and IMS is used to distinguish and quantify α2,6- and α2,3-linked sialic acid isomers based on characteristic fragments. Further, the technique can support the assignment of antenna fucosylation. This feature mapping can confidently assign glycan isomers with multiple sialic acids within one LC-IM-MS run and is fully compatible with existing workflows for N-glycan analysis.


  • Open Access

    Characterizing a novel hyposialylated erythropoietin by intact glycoprotein and glycan analysis

    by Judey Aymed García-Artalejo, Montserrat Mancera-Arteu, Victòria Sanz-Nebot, Teresita Rodríguez, Estela Giménez


  • Analysis of Intact Glycoproteins by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    by Estela Giménez, Montserrat Mancera-Arteu, Fernando Benavente, Victoria Sanz-Nebot

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can be regarded as a key tool to rapidly obtain molecular mass information of intact glycoproteins in glycoproteomic studies and quality control of recombinant biopharmaceuticals. However, MALDI-TOF MS of these glycosylated compounds is a tricky task due to its low ionization efficiency and fragmentation of labile groups such as sialic acids. Here, we offer the reader a practical overview of the available methodologies for the confident analysis of intact glycoproteins with different glycosylation degree by MALDI-TOF MS. The three proposed methods fulfil the requirements of reproducibility and low extent of glycan fragmentation required to successfully analyze intact glycoproteins.