TOTomos F. Owen

Tomos F. Owen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tomos F. Owen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermal and cardiovascular responses to sauna are attenuated by adding cold water immersion to cooling breaks

    by Tomos F. Owen, Callum J. Giles, Samuel F. Leaney, Geoff B. Coombs, Samuel J. Oliver

    The independent effects of different cooling practices, such as cold‐water immersion (CWI), on thermal and cardiovascular responses to sauna remain unclear. This study tested the hypothesis that thermal and cardiovascular responses to sauna are attenuated when CWI was included in a cooling break compared to cooling in air only. In a counterbalanced, crossover design, 16 healthy adults (8 females; age 31 (7) years) participated, on separate visits, in two trials involving 2 × 15 min, 85°C sauna bouts, each followed by a 10‐min cooling break in 23°C air (AIR), or AIR with a 90‐s, 20°C whole‐body CWI. At the end of the second sauna bout, core temperature and heart rate were lower in CWI than AIR ( P ≤ 0.003, 37.55°C versus 38.03°C, −0.48°C [95% CI: −0.71, −0.25], d = 1.28, and 108 bpm versus 125 bpm, −17 bpm [95% CI: −26, −6.6], d = 1.05). Skin temperature was also lower in CWI than in AIR ( P < 0.001). Systolic blood pressure and mean arterial pressure did not differ between conditions ( P ≥ 0.090), whilst diastolic blood pressure was lower in AIR than CWI at the end of cooling breaks and 20 min into recovery ( P ≤ 0.038). Participants reported feeling less hot and more able to tolerate the second sauna in CWI than in AIR ( P ≤ 0.002, d = 1.27 and 0.97). In conclusion, CWI substantially attenuated thermal and cardiovascular strain and improved the perceptual responses to sauna compared with air cooling alone, making sauna more tolerable and reducing heat illness risks.

  • Open Access

    Acute hot‐water immersion augments the diastolic blood pressure nocturnal dip in healthy adults

    by Samuel F. Leaney, Ferrida A. F. Ponce, Tomos F. Owen, Benjamin L. Harvey, Oliver N. Davies‐Wilson, Oliver M. A. Brand, Geoff B. Coombs, Jonathan P. Moore, Samuel J. Oliver

    Hot‐water immersion (HWI) has been shown to reduce 24 h ambulatory systolic blood pressure in hypertensive adults and might represent a preventative strategy for maintaining cardiovascular health in normotensive adults. The purpose of this study was to determine the time course of post‐HWI hypotension and test the hypothesis that a single HWI reduces subsequent 24 h ambulatory blood pressure (ABP) in healthy adults. In a randomized, crossover design, 23 participants [7 female and 16 male; 26 (4) years of age] underwent blood pressure assessments before, during, immediately after and for 24 h following 60 min of immersion in 40.4°C hot water (HWI) and a thermoneutral (24.7°C) air control (CON). Thermal and cardiovascular variables were assessed during and for 60 min after the intervention, after which the participants were instrumented with an ABP monitor for 24 h. At min 60 of the interventions, body core temperature was higher [CON, 36.93 (0.28)°C; HWI, 38.83 (0.19)°C; P < 0.001] and diastolic ( P  < 0.001) and mean ( P  < 0.001) arterial blood pressure lower in HWI than CON. HWI increased the diastolic blood pressure nocturnal dip compared with CON [CON, 15.4 (7.2)%; HWI, 19.1 (7.4)%; P = 0.022]. No differences in ABP were observed for 24 h, daytime or nighttime systolic, diastolic or mean arterial blood pressures (all P  > 0.05). In conclusion, HWI transiently decreased mean arterial blood pressure and diastolic blood pressure for ≤20 min post‐heating and increased the subsequent nocturnal diastolic blood pressure dip in healthy adults.