Abdelaziz Abualshawareb
Research Subjects
Abdelaziz Abualshawareb has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Carola S. König
Department of Mechanical and Aerospace Engineering Brunel University London London UK
3 shared publications - Zahir Dehouche
College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge UB8 3PH, UK
3 shared publications Sergi Ribas
2 shared publications- Ximena Schmidt Rivera
Department of Chemical Engineering, Brunel University London, Uxbridge, United Kingdom
2 shared publications Gerard Jansen
1 shared publicationIoana Pisica
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
System Sizing for Grid-Connected PV-Hybrid Storage with Hourly Dispatch Optimisation Under Inverter and Contracted Power Constraints -An Island Case Study
Grid-connected energy communities on weak or capacity-limited feeders increasingly consider hybrid PVbattery-hydrogen systems, yet planning studies often size assets against annual balances while leaving the grid connection as an effectively unconstrained buffer. Here, we develop a boundary-centred planning architecture that couples long-horizon investment decisions to schedule-feasible operation. A genetic algorithm selects component capacities, inverter rating, and contracted import/export power, while a rolling-horizon MILP (model predictive control) resolves tariff-coupled dispatch with bounded daily load shifting. Using a public-sector community on the island of Formentera (Spain), we benchmark reactive load-following against predictive operation under 0 to 8% flexible demand. Predictive coordination reshapes both, sizing and energy flows by converting temporal foresight into "capacity value" at the point of common coupling. Relative to load-following, the optimiser tightens the contracted exchange envelope from ±78 kW to ±37 kW and reduces the inverter rating from 120 kW to 77 kW, while increasing PV utilisation and reducing grid import reliance to roughly 9-11% of demand. These gains are not driven by indiscriminate oversizing, but by differentiated storage roles: batteries absorb diurnal variability and preserve headroom, while hydrogen buffers longer-duration mismatches. Economically, modest flexibility amplifies the effect, reducing net present cost by 9% and lowering levelised electricity cost from 0.243 to 0.218 €/kWh. Together, the results show that hybrid community value is anchored in enforceable boundary control, and that limited behavioural adaptation can substitute for contracted capacity in weak-grid planning.
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSystem Sizing for Grid-Connected PV-Hybrid Storage with Hourly Dispatch Optimisation Under Inverter and Contracted Power Constraints -An Island Case Study
Grid-connected energy communities on weak or capacity-limited feeders increasingly consider hybrid PVbattery-hydrogen systems, yet planning studies often size assets against annual balances while leaving the grid connection as an effectively unconstrained buffer. Here, we develop a boundary-centred planning architecture that couples long-horizon investment decisions to schedule-feasible operation. A genetic algorithm selects component capacities, inverter rating, and contracted import/export power, while a rolling-horizon MILP (model predictive control) resolves tariff-coupled dispatch with bounded daily load shifting. Using a public-sector community on the island of Formentera (Spain), we benchmark reactive load-following against predictive operation under 0 to 8% flexible demand. Predictive coordination reshapes both, sizing and energy flows by converting temporal foresight into "capacity value" at the point of common coupling. Relative to load-following, the optimiser tightens the contracted exchange envelope from ±78 kW to ±37 kW and reduces the inverter rating from 120 kW to 77 kW, while increasing PV utilisation and reducing grid import reliance to roughly 9-11% of demand. These gains are not driven by indiscriminate oversizing, but by differentiated storage roles: batteries absorb diurnal variability and preserve headroom, while hydrogen buffers longer-duration mismatches. Economically, modest flexibility amplifies the effect, reducing net present cost by 9% and lowering levelised electricity cost from 0.243 to 0.218 €/kWh. Together, the results show that hybrid community value is anchored in enforceable boundary control, and that limited behavioural adaptation can substitute for contracted capacity in weak-grid planning.
- Open Access
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
A Decentralised Plasma Gasification-PEM Fuel Cell System for Hospital Waste-to-Energy: From Waste Characterisation to Techno-Economic Validation
Hospital waste management remains a key barrier to healthcare decarbonisation. This study develops and validates an integrated plasma gasification-proton exchange membrane fuel cell (PEMFC) system for converting hospital offensive waste into hydrogen-based combined heat and power (CHP). A single composite feedstock from Hillingdon Hospital (London, UK) was used for dual thermodynamic validation in Aspen Plus and Cantera, achieving < 5 % deviation in hydrogen yield (0.042 kmol kg⁻¹) and establishing a transparent basis for modelling non-conventional wastes. The plasma gasifier achieved a cold gas efficiency of 46 % and syngas LHV of 8.27 MJ kg⁻¹, confirming efficient conversion of waste carbon to hydrogen-rich gas. PSA-grade hydrogen (10 mol s⁻¹ for 8,000 t yr⁻¹ feed) powered a PEMFC fitted to laboratory polarisation data (RMSE<2%), linking chemical conversion to realistic electrochemical output. System integration across three operational scenarios achieved waste-toenergy efficiencies of 17-21 % and waste-to-hydrogen efficiency of 32 %, corresponding to payback periods below four years and internal rates of return above 30 %. The analysis reveals that continuity of hydrogen utilisation, rather than peak process efficiency, governs economic resilience in decentralised systems. While based on a single feedstock and steady-state modelling, the framework provides a transferable validation route for heterogeneous wastes once compositional variability is characterised. The results position hospital waste treatment as a credible pathway toward self-reliant, low-carbon energy for institutional settings aligned with net-zero policy objectives.
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Decentralised Plasma Gasification-PEM Fuel Cell System for Hospital Waste-to-Energy: From Waste Characterisation to Techno-Economic Validation
Hospital waste management remains a key barrier to healthcare decarbonisation. This study develops and validates an integrated plasma gasification-proton exchange membrane fuel cell (PEMFC) system for converting hospital offensive waste into hydrogen-based combined heat and power (CHP). A single composite feedstock from Hillingdon Hospital (London, UK) was used for dual thermodynamic validation in Aspen Plus and Cantera, achieving < 5 % deviation in hydrogen yield (0.042 kmol kg⁻¹) and establishing a transparent basis for modelling non-conventional wastes. The plasma gasifier achieved a cold gas efficiency of 46 % and syngas LHV of 8.27 MJ kg⁻¹, confirming efficient conversion of waste carbon to hydrogen-rich gas. PSA-grade hydrogen (10 mol s⁻¹ for 8,000 t yr⁻¹ feed) powered a PEMFC fitted to laboratory polarisation data (RMSE<2%), linking chemical conversion to realistic electrochemical output. System integration across three operational scenarios achieved waste-toenergy efficiencies of 17-21 % and waste-to-hydrogen efficiency of 32 %, corresponding to payback periods below four years and internal rates of return above 30 %. The analysis reveals that continuity of hydrogen utilisation, rather than peak process efficiency, governs economic resilience in decentralised systems. While based on a single feedstock and steady-state modelling, the framework provides a transferable validation route for heterogeneous wastes once compositional variability is characterised. The results position hospital waste treatment as a credible pathway toward self-reliant, low-carbon energy for institutional settings aligned with net-zero policy objectives.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Grid‐Constrained Sizing and Predictive Dispatch of a PV–Battery–Hydrogen Energy Community: An Island Case Study
Grid‐connected energy communities on weak or capacity‐limited feeders increasingly consider hybrid photovoltaic (PV)–battery–hydrogen systems yet planning studies often size assets against annual balances while leaving the grid connection as an effectively unconstrained buffer. Here, we develop a boundary‐centred planning architecture that couples long‐horizon investment decisions to schedule‐feasible operation. A genetic algorithm (GA) selects component capacities, inverter rating, and contracted import/export power, while a rolling‐horizon (MILP) formulation implements model predictive control (MPC) resolves tariff‐coupled dispatch with bounded daily load shifting. Using a public‐sector community on the island of Formentera (Spain), we benchmark reactive load‐following against predictive operation under 0% to 8% flexible demand. Predictive coordination reshapes both, sizing and energy flows by converting temporal foresight into “capacity value” at the point of common coupling. Relative to load‐following, the optimiser tightens the contracted exchange envelope from ±78 to ±37 kW and reduces the inverter rating from 120 to 77 kW, while increasing PV utilisation and reducing grid import reliance to roughly 9%–11% of demand. These gains arise from coordinated storage operation: the battery provides mostly short‐term balancing, while hydrogen supplies a smaller secondary contribution through surplus absorption and occasional deficit support. Economically, modest flexibility amplifies the effect, reducing net present cost (NPC) by 9% and lowering levelised electricity cost (LCOE) from 0.243 to 0.218 €/kWh. Together, the results show that hybrid community value is anchored in enforceable boundary control, and that limited behavioural adaptation can substitute for contracted capacity in weak‐grid planning.
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Open AccessGrid‐Constrained Sizing and Predictive Dispatch of a PV–Battery–Hydrogen Energy Community: An Island Case Study
Grid‐connected energy communities on weak or capacity‐limited feeders increasingly consider hybrid photovoltaic (PV)–battery–hydrogen systems yet planning studies often size assets against annual balances while leaving the grid connection as an effectively unconstrained buffer. Here, we develop a boundary‐centred planning architecture that couples long‐horizon investment decisions to schedule‐feasible operation. A genetic algorithm (GA) selects component capacities, inverter rating, and contracted import/export power, while a rolling‐horizon (MILP) formulation implements model predictive control (MPC) resolves tariff‐coupled dispatch with bounded daily load shifting. Using a public‐sector community on the island of Formentera (Spain), we benchmark reactive load‐following against predictive operation under 0% to 8% flexible demand. Predictive coordination reshapes both, sizing and energy flows by converting temporal foresight into “capacity value” at the point of common coupling. Relative to load‐following, the optimiser tightens the contracted exchange envelope from ±78 to ±37 kW and reduces the inverter rating from 120 to 77 kW, while increasing PV utilisation and reducing grid import reliance to roughly 9%–11% of demand. These gains arise from coordinated storage operation: the battery provides mostly short‐term balancing, while hydrogen supplies a smaller secondary contribution through surplus absorption and occasional deficit support. Economically, modest flexibility amplifies the effect, reducing net present cost (NPC) by 9% and lowering levelised electricity cost (LCOE) from 0.243 to 0.218 €/kWh. Together, the results show that hybrid community value is anchored in enforceable boundary control, and that limited behavioural adaptation can substitute for contracted capacity in weak‐grid planning.