IMIsabella Moffitt
Isabella Moffitt
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Isabella Moffitt has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Anne G. M. Schilder
UCL Ear Institute, University College London, 332 Grays Inn Road, London WC1X 8EE, UK
1 shared publication - Liam Barrett
University College London
1 shared publication - Nishchay Mehta
UCL Ear Institute, University College London, 332 Grays Inn Road, London WC1X 8EE, UK
1 shared publication - Roulla Katiri
Hearing Sciences, Mental Health and Clinical Neurosciences, School of Medicine, University of Nottingham, Nottingham, UK
1 shared publication - Yuen Bing Ooi
UCL Ear Institute, University College London, 332 Grays Inn Road, London WC1X 8EE, UK
1 shared publication
Latest Publications
- Open Access
- 18 March 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (6) , 2917
Validated Methods for Synthesising Hearing Health Data for Machine Learning: A Comparative Study of KDE and VAE Approaches
Hearing loss affects approximately 1.5 billion people globally, yet access to comprehensive audiometric datasets for research remains limited due to privacy constraints. Synthetic data generation offers a promising solution, enabling broader data sharing while preserving privacy. This study developed and validated two complementary approaches for synthesising audiometric data: Kernel Density Estimation (KDE) and Variational Autoencoders (VAE). Using the National Health and Nutrition Examination Survey (NHANES) dataset comprising 36,676 participants with comprehensive hearing assessments, we trained both generative models and evaluated synthetic data quality through a rigorous Train-on-Synthetic-Test-on-Real (TSTR) machine learning validation framework and blinded expert clinical assessment by two independent audiologists. The VAE approach achieved 86.3% utility for hearing loss prediction, as compared to the benchmark real data (Train-on-Real-Test-on-Real). Both methods demonstrated strong privacy preservation, with zero exact record matches and robust membership inference attack resistance. Statistical validation confirmed equivalence within clinically negligible margins (<1 dB HL) across all audiometric frequencies. Blinded assessment of 85 patient profiles by two independent expert audiologists revealed that VAE synthetic data achieved high clinical plausibility ratings, with 96.7% of VAE profiles rated as plausible, compared to 13.3% for KDE. Inter-rater reliability was moderate (Cohen’s weighted , ICC ), with 84.7% of ratings within one point, and both raters independently ranking VAE above real data above KDE. These findings establish validated methodologies for generating privacy-preserving synthetic audiometric data suitable for machine learning applications and clinical education, addressing a critical gap in hearing health research infrastructure.- 18 March 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (6) , 2917
Open AccessValidated Methods for Synthesising Hearing Health Data for Machine Learning: A Comparative Study of KDE and VAE Approaches
Hearing loss affects approximately 1.5 billion people globally, yet access to comprehensive audiometric datasets for research remains limited due to privacy constraints. Synthetic data generation offers a promising solution, enabling broader data sharing while preserving privacy. This study developed and validated two complementary approaches for synthesising audiometric data: Kernel Density Estimation (KDE) and Variational Autoencoders (VAE). Using the National Health and Nutrition Examination Survey (NHANES) dataset comprising 36,676 participants with comprehensive hearing assessments, we trained both generative models and evaluated synthetic data quality through a rigorous Train-on-Synthetic-Test-on-Real (TSTR) machine learning validation framework and blinded expert clinical assessment by two independent audiologists. The VAE approach achieved 86.3% utility for hearing loss prediction, as compared to the benchmark real data (Train-on-Real-Test-on-Real). Both methods demonstrated strong privacy preservation, with zero exact record matches and robust membership inference attack resistance. Statistical validation confirmed equivalence within clinically negligible margins (<1 dB HL) across all audiometric frequencies. Blinded assessment of 85 patient profiles by two independent expert audiologists revealed that VAE synthetic data achieved high clinical plausibility ratings, with 96.7% of VAE profiles rated as plausible, compared to 13.3% for KDE. Inter-rater reliability was moderate (Cohen’s weighted , ICC ), with 84.7% of ratings within one point, and both raters independently ranking VAE above real data above KDE. These findings establish validated methodologies for generating privacy-preserving synthetic audiometric data suitable for machine learning applications and clinical education, addressing a critical gap in hearing health research infrastructure.