Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ujjal Mandal has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Robust Numerical Framework for Ultrasonic Wave Characterization in Complex Petrophysical Environments

    by Ujjal Mandal

    Characterizing internal rock heterogeneities, such as pores, vugs, and micro-fractures, represents a fundamental challenge in petrophysics and reservoir engineering. This study presents a robust numerical framework based on the k-space pseudospectral method (k-Wave) to model 1 MHz ultrasonic wave propagation within complex petrophysical environments. A heterogeneous rock model was developed, consisting of a fluid-saturated host matrix with a longitudinal velocity of 2500 m/s, embedded with five discrete circular inclusions assigned a lower velocity of 350 m/s to simulate high-contrast impedance mismatches typical of vuggy porous media. The wave propagation was excited using a 51-element linear source array, and the resulting steady-state acoustic field was analyzed using a 16384-point Fast Fourier Transform (FFT). The simulation results revealed significant scattering effects, wavefront distortions, and the formation of pronounced acoustic shadow zones behind inclusion clusters. Quantitative evaluation was performed using several key metrics, including a Contrast Ratio (CR) of 3.51 dB and an effective attenuation coefficient of 421.95 dB/m, which reflect the combined influence of intrinsic absorption and extrinsic scattering. The stability of the framework was further enhanced by integrating the Convergent Born Series (CBS) protocol and fractional viscoacoustic modeling to account for frequency-dependent power-law absorption. Crucially, a comparative validation between the k-Wave results and the Modified Born Approach (MBA) showed a numerical discrepancy of less than $1\%$, confirming the high precision of the proposed model. This framework provides an accurate and computationally efficient tool for interpreting ultrasonic testing data, facilitating the non-destructive estimation of porosity and inclusion density in heterogeneous porous media.


  • Open Access

    FDTD analysis of TA waves

    by Ujjal Mandal

    This study presents the numerical simulation of thermoacoustic (TA) wave propagation in time domain using the Finite Difference Time Domain (FDTD) method, along with a comparative analysis against the k-Space pseudospectral method (k-Wave). A physically realistic thermoacoustic source is modeled using a Gaussian initial pressure distribution, and the resulting pressure signals are recorded using a point sensor. The numerical results obtained from both methods show excellent agreement for different grid resolutions when a fixed Courant-Friedrichs-Lewy (CFL) number is maintained. However, discrepancies arise when different CFL numbers are used for varying grid resolutions, leading to mismatched signal responses. Further investigations are conducted using various realistic source configurations, including circular (disk), Chebyshev polynomial based ($1^{st}$ order), and asymmetric (rock-like) shapes. The corresponding time domain signals and frequency spectra are analyzed using both FDTD and k-space methods. It is observed that the two methods exhibit strong agreement in the low frequency regime, while noticeable deviations occur at higher frequencies. Further the study highlights the limitations associated with binary image based sources. Sharpe discontinuities at the edges introduces non-physical high frequency components, resulting in spurious oscillations and degraded signal quality. A multi sensor configuration is utilized to analyze the signals at different locations.


  • Graphics processing unit accelerated Helmholtz equation solver in two dimensions using the traditional Born series formulation for linear and nonlinear media in biomedical ultrasound

    by Ujjal Mandal, Jagpreet Singh, Ben T. Cox, Ratan K. Saha

    This study numerically solves inhomogeneous Helmholtz equations modeling acoustic wave propagation in homogeneous and lossless, absorbing and dispersive, and inhomogeneous and nonlinear media. The traditional Born series (TBS) method has been employed to solve such equations. Simulated pressure field patterns for a linear array of acoustic sources (a line source) estimated by the TBS procedure exhibit excellent agreement with that of a standard time domain approach (the k-wave toolbox). For instance, the maximum absolute error of normalized pressure amplitude made by the proposed technique for the homogeneous and lossless medium is ≈2% with respect to the latter method. The TBS scheme, though iterative, is a very fast method. For example, the graphics processing unit (GPU)-enabled cuda c code implementing the TBS procedure for calculating the pressure field for the homogeneous and lossless medium is 102× faster than the k-wave module and also 4× faster than the corresponding central processing unit C code for the computational domain considered in this study (4096×4096). The findings of this study demonstrate the effectiveness of the TBS method for solving inhomogeneous Helmholtz equation, while the GPU-based implementation significantly reduces the computation time. In this work, the capability and performance of the method have been tested in two dimensions only.

  • Open Access

    GPU Accelerated Transducer-Field Calculation using the Traditional Born Series Formulation for Realistic Media

    by Ujjal Mandal, Jagpreet Singh, Ben T Cox, Ratan K Saha

    This study numerically solves inhomogeneous Helmholtz equations modeling acoustic wave propagation in homogeneous and lossless, absorbing and dispersive, inhomogeneous and nonlinear media. The traditional Born series (TBS) method has been employed to solve such equations. The full wave solution in this methodology is expressed as an infinite sum of the solution of the unperturbed equation weighted by increasing power of the potential. Simulated pressure field patterns for a linear array of acoustic sources (a line source) estimated by the TBS procedure exhibit excellent agreement with that of a standard time domain approach (k-Wave toolbox). The TBS scheme though iterative but is a very fast method. For example, GPU enabled CUDA C code implementing the TBS procedure takes 5 s to calculate the pressure field for the homogeneous and lossless medium whereas nearly 500 s is taken by the later module. The execution time for the corresponding CPU code is about 20 s. The findings of this study demonstrate the effectiveness of the TBS method for solving inhomogeneous Helmholtz equation, while the GPU-based implementation significantly reduces the computation time. This method can be explored in practice for calculation of pressure fields generated by real transducers designed for diverse applications.

  • Open Access

    Efficient implementations of a Born Series for computing photoacoustic field from a collection of erythrocytes

    by Ujjal Mandal, Navroop Singh, Kartikay Singh, Vinit Nana Hagone, Jagpreet Singh, Anshu S. Anand, Ben T. Cox, Ratan K. Saha


  • On the Born series methods for solving inhomogeneous Helmholtz equation in biomedical photoacoustics

    by Ujjal Mandal, Jagpreet Singh, Ratan K. Saha

    The Born series methods, namely, Traditional Born Series (TBS) and Convergent Born Series (CBS), have been recently implemented to numerically solve the time-independent Photoacoustic (PA) wave equation for an acoustically inhomogeneous source. The TBS algorithm diverges when the sound-speed mismatch is ⪆20%, however, the CBS technique provides faithful result even beyond this limit. These protocols are iterative in nature and computationally expensive. Currently, MATLAB-based implementations are available to study PA emission from a single source mimicking a cell. However, efficient numerical implementation strategy is further needed particularly to calculate PA field from a tissue. Therefore, to develop insights, uniprocessor-based C codes were realized for these schemes. The PA field (in 2D) was computed at a distance 35 μm from a source (a light absorbing disc of radius 7.5 μm) over a frequency range from 7.32 to 512 MHz with a resolution of 7.32 MHz. The sound-speed within the source region was varied from vs = 1200, 1500 and 1800 m/s, but the same quantity for the ambient medium was fixed to vf = 1500 m/s. The C program was found to be at least ten times slower than the corresponding MATLAB program. It may be because MATLAB inherently implements parallel computing while evaluating the forward and backward Fast Fourier Transforms (FFTs) associated with the Born series approaches. Multiprocessor-based FFTs and parallel nested loops are being incorporated into the C program for enhancement of its execution speed.

  • Estimation of photoacoustic spectra for normal and pathological red blood cells using a modified Green’s function approach

    by Ratan K. Saha, Ujjal Mandal

    The frequency domain Optoacoustic (OA) wave equation is inherently inhomogeneous. The first inhomogeneous term arises because of the OA effect (i.e., conversion of optical energy into acoustical energy). The second term appears due to sound-speed mismatch between the source and the ambient medium. The conventional Green’s function method works well in absence of the second term (i.e., acoustically homogeneous source). Recently, it has been shown that a Modified Green’s Function (MGF) approach provides faithful solution to the OA wave equation for an acoustically inhomogeneous source. Herein, we employ the MGF technique for accurate estimation of the OA spectra for normal and pathological red blood cells (RBCs). The shapes in 2D mimicking normal RBC, stomatocyte and echinocyte (with six equidistant identical spicules) were simulated (with constant area ≈ 16.5 μm2 ) and subsequently, the OA spectra were computed over 10- 1000 MHz by evaluating the integral equation employing the Monte Carlo integration method. The OA spectrum for an equivalent disc was also calculated for comparison. The sound-speed within the source region was taken as 1639 m/s and that of the surrounding medium was chosen as 1500 m/s. The first minimum of the OA spectra for disc and echinocyte appeared almost at the same location (440 MHz) when probed from an angle, θ=π/4 with respect to the axis of symmetry. The locations for the first minimum became 280 and 390 MHz, respectively for normal RBC and stomatocyte (for θ=π/4). These 0A spectral features may be useful for morphological characterization of normal and deformed RBCs.