LXLingfeng Xie
Lingfeng Xie
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lingfeng Xie has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Fei Gao
Tsinghua University
2 shared publications - Xiang Xiao
School of Physics Sun Yat-Sen University 510275 Guangzhou China
2 shared publications - Xiaoran Guo
University of Science and Technology of China
2 shared publications - Yifei Zhao
Department of Physics and Center for High Energy Physics, Tsinghua University, Beijing 100084, People’s Republic of China
2 shared publications Bingwei Zhang
CNNC Sanmen Nuclear Power Company
1 shared publicationChang Cai
Tsinghua University
1 shared publication
Latest Publications
- Open Access
- 6 April 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (4)
Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment
The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dual-phase xenon time projection chamber (TPC). To validate the detector concept and ensure technical reliability for the full-scale experiment, a dedicated prototype was designed, constructed, and operated. This work presents an overview of the design, construction, and operational performance of the prototype, with emphasis on its major subsystems, including the TPC, cryogenics and xenon purification systems, slow control, and data acquisition. During operation, the detector demonstrated the capability to achieve a sub-keV energy threshold required for the RELICS physics program, as reflected by a measured single electron gain of (34.30 ± 0.01 (stat.)) PE/e $$^-$$ and the successful detection of $$\mathrm {0.27~keV}$$ L-shell decay events from $$\mathrm {^{37}Ar}$$ . In addition, essential data analysis techniques and simulation frameworks were developed and validated, establishing the technical foundation for future RELICS operations. The successful construction and operation of this prototype confirm the feasibility of the core technologies and provide the experimental basis for the full-scale RELICS detector.- 6 April 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (4)
Open AccessDevelopment of a dual-phase xenon time projection chamber prototype for the RELICS experiment
The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dual-phase xenon time projection chamber (TPC). To validate the detector concept and ensure technical reliability for the full-scale experiment, a dedicated prototype was designed, constructed, and operated. This work presents an overview of the design, construction, and operational performance of the prototype, with emphasis on its major subsystems, including the TPC, cryogenics and xenon purification systems, slow control, and data acquisition. During operation, the detector demonstrated the capability to achieve a sub-keV energy threshold required for the RELICS physics program, as reflected by a measured single electron gain of (34.30 ± 0.01 (stat.)) PE/e $$^-$$ and the successful detection of $$\mathrm {0.27~keV}$$ L-shell decay events from $$\mathrm {^{37}Ar}$$ . In addition, essential data analysis techniques and simulation frameworks were developed and validated, establishing the technical foundation for future RELICS operations. The successful construction and operation of this prototype confirm the feasibility of the core technologies and provide the experimental basis for the full-scale RELICS detector.