Andreas Ridder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andreas Ridder has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bernd Ponick
Institute for Drive Systems and Power Electronics (IAL), Leibniz University Hannover, Hannover, Germany
2 shared publications Dirk Emmrich
2 shared publications- Amir Ebrahimi
Institute for Electrical Drives, Power Electronics, and Devices, University of Bremen, Bremen, Germany
1 shared publication Eva Bresemann
1 shared publication- Marius Meiswinkel
Institute for Electrical Drives, Power Electronics, and Devices, University of Bremen, Bremen, Germany
1 shared publication - Marvin Hengelsberg1 shared publication
Latest Publications
- Open Access
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 42515-42526
Contactless Telemetry System for Condition Monitoring of Large Hydro and Wind Generators
Condition monitoring and predictive maintenance of large hydro and wind generators are essential for reducing operational costs and improving system availability. However, traditional monitoring approaches rely primarily on stator-side measurements and bearing vibrations, providing limited observability of rotor-side phenomena where many critical faults originate. This paper presents a comprehensive modular contactless rotor telemetry platform designed for direct rotor-side measurement of multiple physical quantities including magnetic flux density, temperatures, damper winding currents, and mechanical vibrations. The system architecture prioritizes flexibility and scalability, enabling easy integration of different sensor types with configurable sampling rates and resolutions. In a laboratory research environment, fixed sensor configurations and rigid sampling parameters often become limiting factors. The proposed modular design addresses these constraints by allowing users to dynamically add or remove acquisition modules, adapt sampling parameters for specific experiments, and perform on-rotor preprocessing to optimize data transmission bandwidth. Detailed descriptions of the hardware design, synchronization strategy, communication protocol, and software architecture are provided. Experimental validation is demonstrated on a 366 kVA research hydro generator, demonstrating the system’s capability for reliable, synchronized multichannel acquisition on a rotating platform with contactless data transmission. The prototype scales up to 64 simultaneous channels (8 acquisition modules) using 16-bit simultaneous-sampling ADCs and achieves about 28 h runtime at approximately 6.8Wtotal rotor-side power consumption using a 190Wh battery pack.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 42515-42526
Open AccessContactless Telemetry System for Condition Monitoring of Large Hydro and Wind Generators
Condition monitoring and predictive maintenance of large hydro and wind generators are essential for reducing operational costs and improving system availability. However, traditional monitoring approaches rely primarily on stator-side measurements and bearing vibrations, providing limited observability of rotor-side phenomena where many critical faults originate. This paper presents a comprehensive modular contactless rotor telemetry platform designed for direct rotor-side measurement of multiple physical quantities including magnetic flux density, temperatures, damper winding currents, and mechanical vibrations. The system architecture prioritizes flexibility and scalability, enabling easy integration of different sensor types with configurable sampling rates and resolutions. In a laboratory research environment, fixed sensor configurations and rigid sampling parameters often become limiting factors. The proposed modular design addresses these constraints by allowing users to dynamically add or remove acquisition modules, adapt sampling parameters for specific experiments, and perform on-rotor preprocessing to optimize data transmission bandwidth. Detailed descriptions of the hardware design, synchronization strategy, communication protocol, and software architecture are provided. Experimental validation is demonstrated on a 366 kVA research hydro generator, demonstrating the system’s capability for reliable, synchronized multichannel acquisition on a rotating platform with contactless data transmission. The prototype scales up to 64 simultaneous channels (8 acquisition modules) using 16-bit simultaneous-sampling ADCs and achieves about 28 h runtime at approximately 6.8Wtotal rotor-side power consumption using a 190Wh battery pack.
- Open Access
- 2 March 2026
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 143 (2) , 101-112
Influence of damper winding topology on additional rotor Joule losses in converter-fed synchronous machines for hydropower plants
Salient-pole synchronous machines have been a common technology in pumped storage hydropower plants for decades. With the help of a full-scale converter, the electric machine can be operated at variable speeds, which is becoming increasingly important due to the growing number of fluctuating renewable energy sources in the grid. Due to the converter’s switching behavior when connected to the stator winding, additional harmonic currents are induced in the damper and field windings via the magnetic field in the air gap. This study aims to qualitatively investigate the influence of different damper winding topologies on the induced voltage and resistance factor of the field winding as well as on the total additional AC Joule losses in the rotor windings related to the converter. The machine design is based on a real research hydro generator. In addition to the reference machine, three other rotor topologies are investigated: one with a short-circuited ring between the field winding and the pole shoe, one with a larger gap between the pole shoe and the field winding, and one with a wider pole shoe. For each of the topologies, three different damper bar arrangements are investigated. The calculations are based on FEM simulations that cover a frequency range from 0.01 Hz to 15 kHz and consider load-point-dependent saturation caused by the fundamental harmonic. This paper is important for the future design of variable speed salient-pole synchronous machines in pumped storage hydropower plants, as the results show the potential to significantly reduce additional AC Joule losses in the rotor windings.
- 2 March 2026
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 143 (2) , 101-112
Open AccessInfluence of damper winding topology on additional rotor Joule losses in converter-fed synchronous machines for hydropower plants
Salient-pole synchronous machines have been a common technology in pumped storage hydropower plants for decades. With the help of a full-scale converter, the electric machine can be operated at variable speeds, which is becoming increasingly important due to the growing number of fluctuating renewable energy sources in the grid. Due to the converter’s switching behavior when connected to the stator winding, additional harmonic currents are induced in the damper and field windings via the magnetic field in the air gap. This study aims to qualitatively investigate the influence of different damper winding topologies on the induced voltage and resistance factor of the field winding as well as on the total additional AC Joule losses in the rotor windings related to the converter. The machine design is based on a real research hydro generator. In addition to the reference machine, three other rotor topologies are investigated: one with a short-circuited ring between the field winding and the pole shoe, one with a larger gap between the pole shoe and the field winding, and one with a wider pole shoe. For each of the topologies, three different damper bar arrangements are investigated. The calculations are based on FEM simulations that cover a frequency range from 0.01 Hz to 15 kHz and consider load-point-dependent saturation caused by the fundamental harmonic. This paper is important for the future design of variable speed salient-pole synchronous machines in pumped storage hydropower plants, as the results show the potential to significantly reduce additional AC Joule losses in the rotor windings.
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-11
Additional AC Copper Losses in the Field Winding of Converter-Fed Synchronous Machines for Pumped Storage Hydropower Plants
Converter-fed synchronous machines for variable speed pumped storage hydropower plants are becoming increasingly important as the share of fluctuating renewable energy increases. The inverter connected to the stator terminals causes additional harmonic currents in the stator winding, which induce additional harmonic currents in the field winding. Due to the eddy current effects and the typical form-wound coil design, these additional harmonic currents in the field winding can lead to significant additional losses, even with relatively small amplitudes. The aim of this paper is to calculate these additional losses. Therefore, numerical calculations are used to determine the resistance factor for a frequency band from $\text{0}\,\text{Hz}$ to $\text{15}\,\text{kHz}$ while also considering saturation. In addition, two measurements are carried out on a research hydro generator at different inverter switching frequencies. Using the measured currents and determined resistance factors, the additional losses due to the switching frequency are calculated and validated using a temperature measurement in the field winding. The results of this work are important for the future design and cooling of large converter-fed synchronous machines with form-wound field coils, as the additional AC losses in the field winding are usually neglected.
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1-11
Additional AC Copper Losses in the Field Winding of Converter-Fed Synchronous Machines for Pumped Storage Hydropower Plants
Converter-fed synchronous machines for variable speed pumped storage hydropower plants are becoming increasingly important as the share of fluctuating renewable energy increases. The inverter connected to the stator terminals causes additional harmonic currents in the stator winding, which induce additional harmonic currents in the field winding. Due to the eddy current effects and the typical form-wound coil design, these additional harmonic currents in the field winding can lead to significant additional losses, even with relatively small amplitudes. The aim of this paper is to calculate these additional losses. Therefore, numerical calculations are used to determine the resistance factor for a frequency band from $\text{0}\,\text{Hz}$ to $\text{15}\,\text{kHz}$ while also considering saturation. In addition, two measurements are carried out on a research hydro generator at different inverter switching frequencies. Using the measured currents and determined resistance factors, the additional losses due to the switching frequency are calculated and validated using a temperature measurement in the field winding. The results of this work are important for the future design and cooling of large converter-fed synchronous machines with form-wound field coils, as the additional AC losses in the field winding are usually neglected.