Alejandro Castellanos Alonso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alejandro Castellanos Alonso has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Antonio M. Lopez
Multisensor Systems and Robotics Research Group (SiMuR), Electrical Engineering Department, University of Oviedo, 33204 Gijón, Spain
2 shared publications - Diego Álvarez
Multisensor Systems and Robotics Research Group (SiMuR), Electrical Engineering Department, University of Oviedo, 33204 Gijón, Spain
2 shared publications - Gonzalo García Carro
Multisensor Systems and Robotics Research Group (SiMuR), Electrical Engineering Department, University of Oviedo, 33204 Gijón, Spain
2 shared publications - Juan Carlos Alvarez
Multisensor Systems and Robotics Research Group (SiMuR), Electrical Engineering Department, University of Oviedo, 33204 Gijón, Spain
2 shared publications - Ana Carbonell-Baeza
MOVE-IT Research Group and Department of Physical Education, Faculty of Education Sciences, University of Cádiz, Cádiz, Spain
1 shared publication - Asier Mañas
CIBER de Fragilidad y Envejecimiento Saludable, CIBERFES, Instituto de Salud Carlos III, Spain; Faculty of Education, Psychology and Sport Sciences, University of Huelva, Spain
1 shared publication
Latest Publications
- Open Access
Impact of Gyroscope Integration, Sensor Placement, and Activity Granularity on Human Activity Recognition Performance
This study systematically evaluates the impact of sensor configuration, body location, classification granularity, and model choice on inertial-based human activity recognition in a laboratory dataset aligned with the Spanish IMPaCT cohort design. Data were collected from 85 participants instrumented with thigh-, wrist-, and hip-mounted inertial measurement units over a structured protocol of 13 semi-structured daily activities, a resting phase and a structured activity. After manual correction of timestamp drift, signals were segmented into overlapping 10-s windows and analyzed using convolutional neural networks, Random Forest, and XGBoost classifiers.Two classification targets were defined: fine-grained recognition of 15 laboratory-controlled activities and coarse-grained classification into four MET-based intensity levels. Results showed that classification granularity is the primary determinant of performance (, p-value = through the analysis of variance of the F1-score), with intensity-level classification substantially outperforming fine-grained activity recognition. Sensor configuration, model type, and body location also significantly influenced classification outcomes. Wrist-mounted sensors achieved the highest overall F1-scores. Incorporating gyroscope-derived features consistently improved performance across configurations, and feature importance analysis confirmed their substantial contribution. These findings, derived from models developed under controlled laboratory conditions, provide practical guidance for the design of wearable sensing protocols and modeling strategies in large-scale population-based studies, and support their extension to everyday physical activity, laying the foundation for future real-world applications.Open AccessImpact of Gyroscope Integration, Sensor Placement, and Activity Granularity on Human Activity Recognition Performance
This study systematically evaluates the impact of sensor configuration, body location, classification granularity, and model choice on inertial-based human activity recognition in a laboratory dataset aligned with the Spanish IMPaCT cohort design. Data were collected from 85 participants instrumented with thigh-, wrist-, and hip-mounted inertial measurement units over a structured protocol of 13 semi-structured daily activities, a resting phase and a structured activity. After manual correction of timestamp drift, signals were segmented into overlapping 10-s windows and analyzed using convolutional neural networks, Random Forest, and XGBoost classifiers.Two classification targets were defined: fine-grained recognition of 15 laboratory-controlled activities and coarse-grained classification into four MET-based intensity levels. Results showed that classification granularity is the primary determinant of performance (, p-value = through the analysis of variance of the F1-score), with intensity-level classification substantially outperforming fine-grained activity recognition. Sensor configuration, model type, and body location also significantly influenced classification outcomes. Wrist-mounted sensors achieved the highest overall F1-scores. Incorporating gyroscope-derived features consistently improved performance across configurations, and feature importance analysis confirmed their substantial contribution. These findings, derived from models developed under controlled laboratory conditions, provide practical guidance for the design of wearable sensing protocols and modeling strategies in large-scale population-based studies, and support their extension to everyday physical activity, laying the foundation for future real-world applications. - Open Access
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Evaluation of Magnetometer-Less Inertial Sensors for Static and Dynamic Spatial Orientation Estimation
This study introduces a magnetometer-free, custom-built inertial measurement unit (IMU) combined with an open-source sensor fusion algorithm and provides a systematic experimental comparison against commercial IMUs that integrate proprietary hardware and closed-source filtering software. The main innovation lies in demonstrating that an open and fully reproducible hardware and software architecture can achieve orientation estimation accuracy comparable to that of state-of-the-art commercial solutions under both static and dynamic conditions. Experimental results show that the proposed system achieves a mean orientation error of 2.10% (0.11°) while consistently outperforming proprietary filtering approaches in static scenarios and exhibiting competitive variability during dynamic motion. Furthermore, the study presents a comprehensive benchmarking framework that analyzes the influence of sensor noise characteristics and filtering strategy on estimation performance across multiple hardware and algorithm configurations. These findings establish that custom-built IMUs paired with open-source sensor fusion algorithms constitute a reliable, cost-effective, and transparent alternative to commercial hardware and software solutions for biomedical and engineering applications.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Open AccessEvaluation of Magnetometer-Less Inertial Sensors for Static and Dynamic Spatial Orientation Estimation
This study introduces a magnetometer-free, custom-built inertial measurement unit (IMU) combined with an open-source sensor fusion algorithm and provides a systematic experimental comparison against commercial IMUs that integrate proprietary hardware and closed-source filtering software. The main innovation lies in demonstrating that an open and fully reproducible hardware and software architecture can achieve orientation estimation accuracy comparable to that of state-of-the-art commercial solutions under both static and dynamic conditions. Experimental results show that the proposed system achieves a mean orientation error of 2.10% (0.11°) while consistently outperforming proprietary filtering approaches in static scenarios and exhibiting competitive variability during dynamic motion. Furthermore, the study presents a comprehensive benchmarking framework that analyzes the influence of sensor noise characteristics and filtering strategy on estimation performance across multiple hardware and algorithm configurations. These findings establish that custom-built IMUs paired with open-source sensor fusion algorithms constitute a reliable, cost-effective, and transparent alternative to commercial hardware and software solutions for biomedical and engineering applications.