Alexander Fischer
Alexander Fischer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Bhooshit Patel
1 shared publication- Christian Hühne
Technische Universität Braunschweig
1 shared publication - Hisashi Kumazawa
Japan Aerospace Exploration Agency , 7-44-1 Jindaiji Higashi-machi , Chofu-shi , Tokyo , Japan
1 shared publication - Josef Koord
German Aerospace Center (DLR), Institute of Lightweight Systems
1 shared publication Maria Moix-Bonet
1 shared publication- Oliver Volkerink
Institute of Mechanics and Adaptronics, Fakultät für Maschinenbau, Technische Universität Braunschweig, Braunschweig, Germany
1 shared publication
Latest Publications
- 1 August 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (8)
Comparative Temperature-Dependent Performance of Hard, Soft, and Very-Soft PZT Transducers for Guided Wave Structural Health Monitoring
Structural Health Monitoring (SHM) has emerged as a candidate approach for cryogenic hydrogen systems, reusable launch vehicles, and space structures operating under extreme environmental and operational conditions (EOCs). Reliable SHM across such conditions requires both compensation of EOC influences and stable transducer behavior over the full temperature range. In guided wave (GW)-based SHM, this is particularly critical because of the strong temperature dependence of piezoceramic materials. This work presents a comparative study of hard (HRD-PZT), soft (SFT-PZT) and very-soft (VSF-PZT) Lead Zirconate-Titanate transducers from approximately 27 K to 353 K. Electromechanical impedance (EMI) measurements on unbonded discs in a helium cryostat and in a climate chamber were used to extract the temperature-dependent d31 coefficient via the radial-mode procedure. Guided wave experiments were performed on an instrumented copper plate in the same cryostat (40–290 K) and on aluminum plates in a climate chamber (233–353 K), enabling a cross-substrate consistency check. At room temperature, the EMI measurements reproduce the expected VSF > SFT > HRD ordering, and the GW measurements show the same observed ordering. At cryogenic temperatures the EMI hierarchy is preserved, VSF-PZT retains the largest absolute d31, but the GW amplitude hierarchy reverses: HRD-PZT delivers the largest A0- and S0-mode amplitudes below approximately 220 K. GW amplitudes are well described by a two-stage linear trend for HRD-PZT and by a sigmoidal trend for SFT- and VSF-PZT. In the climate-chamber range, a non-monotonic behaviour with a maximum near 310–320 K is consistent with softening of the structural adhesive near its glass-transition temperature. These results highlight that transducer selection for cryogenic SHM cannot rely on room-temperature datasheet values alone and must combine intrinsic piezoelectric properties with the temperature-dependent electromechanical coupling to the host structure
- 1 August 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (8)
Comparative Temperature-Dependent Performance of Hard, Soft, and Very-Soft PZT Transducers for Guided Wave Structural Health Monitoring
Structural Health Monitoring (SHM) has emerged as a candidate approach for cryogenic hydrogen systems, reusable launch vehicles, and space structures operating under extreme environmental and operational conditions (EOCs). Reliable SHM across such conditions requires both compensation of EOC influences and stable transducer behavior over the full temperature range. In guided wave (GW)-based SHM, this is particularly critical because of the strong temperature dependence of piezoceramic materials. This work presents a comparative study of hard (HRD-PZT), soft (SFT-PZT) and very-soft (VSF-PZT) Lead Zirconate-Titanate transducers from approximately 27 K to 353 K. Electromechanical impedance (EMI) measurements on unbonded discs in a helium cryostat and in a climate chamber were used to extract the temperature-dependent d31 coefficient via the radial-mode procedure. Guided wave experiments were performed on an instrumented copper plate in the same cryostat (40–290 K) and on aluminum plates in a climate chamber (233–353 K), enabling a cross-substrate consistency check. At room temperature, the EMI measurements reproduce the expected VSF > SFT > HRD ordering, and the GW measurements show the same observed ordering. At cryogenic temperatures the EMI hierarchy is preserved, VSF-PZT retains the largest absolute d31, but the GW amplitude hierarchy reverses: HRD-PZT delivers the largest A0- and S0-mode amplitudes below approximately 220 K. GW amplitudes are well described by a two-stage linear trend for HRD-PZT and by a sigmoidal trend for SFT- and VSF-PZT. In the climate-chamber range, a non-monotonic behaviour with a maximum near 310–320 K is consistent with softening of the structural adhesive near its glass-transition temperature. These results highlight that transducer selection for cryogenic SHM cannot rely on room-temperature datasheet values alone and must combine intrinsic piezoelectric properties with the temperature-dependent electromechanical coupling to the host structure
- Open Access
- 4 March 2026
- Published by Elsevier in Composites Part B: Engineering
- Vol. 316
Investigation of permeability and leakage in composite materials for application in cryogenic storage systems
- 4 March 2026
- Published by Elsevier in Composites Part B: Engineering
- Vol. 316
Open AccessInvestigation of permeability and leakage in composite materials for application in cryogenic storage systems