Marie Pospíšilová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marie Pospíšilová has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Aleksei Pashchenko
Department of Biomedical Sciences, University of Sassari, 07100 Sassari, Italy
1 shared publication - Alois Nečas
Faculty of Veterinary Medicine, University of Veterinary and Sciences Brno, Brno, Czech Republic
1 shared publication Bruno Sopko
Second Faculty of Medicine, Charles University, Prague, Czech Republic
1 shared publication- Evzen Amler
Institute of Biophysics, 2nd Faculty of Medicine, Charles University, V Uvalu 84, 150 06 Prague 5, Czech Republic
1 shared publication - Gracian Tejral
Second Faculty of Medicine, Charles University, Prague, Czech Republic
1 shared publication - Hana Kalábová
Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 16 March 2026
- Published by Springer Nature in European Biophysics Journal
- Vol. 55 (4) , 1-15
Fluorescent bionanosensor for picomolar detection of biomarkers in fluids
Fast and simple detection of diseases at their early stage and clinical monitoring of healing progress directly from body fluids, namely from urine, is a hot topic in modern personalized medicine. Functionalized nanofibers seem to be an ideal solution for the construction of specific and highly selective detection systems and microfluidic tools due to their extremely high ratio between their surface and volume, and also tunable sensitivity. The aim of this study is development of biosensors based on functionalized nanofibers leading to signal enhancement which would enable fluorescence detection and improve diagnostic accuracy in human fluids. Functionalized-PolyAcrylNnitrile (fPAN) membranes were fabricated and analyzed via SEM and fluorescence spectroscopy. Biotin-FITC binding was tested using a routine filtration setup and quantified with a Fluoromax4 spectrometer. Avidin-functionalized membranes showed strong, specific binding at picomolar levels Since the collected urine can be easily collected at volumes of more than 100 mL, and fluorescence measurement performed at a significantly smaller volume than 1 mL, our nanofiber-based system serves as an efficient specific enhancer and increases, thus, the detection limit by more than two orders of magnitude. This is already sufficient, for example, for a reliable fluorescence detection of urine markers in subpicomolar concentrations. Thus, this study describes a novel detection approach and application of fluorescence bionanosensors based on specifically functionalized polyacrylonitrile nanofibers for monitoring of subpicomolar concentrated markers in human fluids. These concentrations allow already monitoring of serious diseases at their early stage, which is crucial for distant and precision medicine.
- 16 March 2026
- Published by Springer Nature in European Biophysics Journal
- Vol. 55 (4) , 1-15
Open AccessFluorescent bionanosensor for picomolar detection of biomarkers in fluids
Fast and simple detection of diseases at their early stage and clinical monitoring of healing progress directly from body fluids, namely from urine, is a hot topic in modern personalized medicine. Functionalized nanofibers seem to be an ideal solution for the construction of specific and highly selective detection systems and microfluidic tools due to their extremely high ratio between their surface and volume, and also tunable sensitivity. The aim of this study is development of biosensors based on functionalized nanofibers leading to signal enhancement which would enable fluorescence detection and improve diagnostic accuracy in human fluids. Functionalized-PolyAcrylNnitrile (fPAN) membranes were fabricated and analyzed via SEM and fluorescence spectroscopy. Biotin-FITC binding was tested using a routine filtration setup and quantified with a Fluoromax4 spectrometer. Avidin-functionalized membranes showed strong, specific binding at picomolar levels Since the collected urine can be easily collected at volumes of more than 100 mL, and fluorescence measurement performed at a significantly smaller volume than 1 mL, our nanofiber-based system serves as an efficient specific enhancer and increases, thus, the detection limit by more than two orders of magnitude. This is already sufficient, for example, for a reliable fluorescence detection of urine markers in subpicomolar concentrations. Thus, this study describes a novel detection approach and application of fluorescence bionanosensors based on specifically functionalized polyacrylonitrile nanofibers for monitoring of subpicomolar concentrated markers in human fluids. These concentrations allow already monitoring of serious diseases at their early stage, which is crucial for distant and precision medicine.