SJSadheesh Kumar S. Jayaraman

Sadheesh Kumar S. Jayaraman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sadheesh Kumar S. Jayaraman has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A predictive OLTC control strategy for voltage regulation with reduced tap changes in solar PV – integrated 11 kV/433 V distribution substation

    by Sadheesh Kumar S. Jayaraman, Navin Sam Kamaraj, Ram Jethmalani C. Hemparuva

    The mass deployment of solar photovoltaic generation in distribution networks induces rapid voltage variations, reverse power flow, and frequent on-load tap changes, thereby undermining voltage quality and the longevity of on-load tap changing units. Classical on-load tap-changing controllers can only act on instantaneous voltage readings and, as a result, exhibit a reactive response to disturbances caused by solar photovoltaic generation, inevitably leading to unnecessary tap changes and tap-hunting behaviour. The current work presents a predictive control algorithm based on a family of rules that follows the principles of model predictive control logic and tap-budget control, similar to the token-bucket algorithm used in computer networks. This on-load tap changing-predictive control algorithm model includes: (i) a low-price, field-tested on-load tap change retrofit controller with phase-sequence detection and hysteresis-based intelligent tap logic, and (ii) short-term solar photovoltaic generation voltage prediction based on different deep learning techniques. The tap actions are also activated when the measured and predicted deviations exceed their respective limits, making predictive voltage regulation possible and reducing mechanical wear and tear. When testing, validation is performed using a 1-year dataset for an 11 kV/433 V campus feeder with a 2 MW peak load and optional 0.5, 1, and 1.5 MW distributed solar photovoltaic plants. Findings indicate improved voltage regulation performance, with approximately 57 % fewer tap operations, while maintaining stable voltage regulation under reverse power flow conditions and phase reversal conditions. The suggested methodology provides a scalable, cost-effective solution for modernizing on-load tap-changing systems in distribution networks in developing regions.

  • Effect of parameterized activation functions on the performance of LSTM models for state of charge (SoC) estimation in EV batteries

    by Sahukari Bhavana, Vellure Rahul, Venkadesan Arunachalam, Sadheesh Kumar S Jayaraman, Ram Jethmalani C Hemaparuva, Jojin Thomas

    State of charge (SoC) represents the remaining capacity of a battery relative to its fully charged state and is a critical indicator of electric vehicle (EV) performance and driving range. Accurate SoC estimation is essential for effective battery management systems. Conventional methods such as Coulomb counting, open-circuit voltage, and Kalman filtering often suffer from reduced accuracy under varying operating conditions. long short-term memory (LSTM) networks effectively capture the nonlinear and temporal characteristics of battery behavior; however, the impact of activation function parameters within LSTM cells has not been thoroughly investigated. In this work, the impact of parameterized activation functions on the performance of LSTM models for SoC estimation in lithium-ion electric vehicle batteries is investigated. By introducing a scaling factor λ to the standard log sigmoid and tan sigmoid activation functions, the gradient profiles during training are modified. The empirical results demonstrate that modulating the scaling parameter λ directly reshapes the internal gradient landscape of the recurrent cells, fundamentally enhancing sequence tracking precision. The proposed approach achieves its peak SoC estimation performance at an optimal scaling value of λ = 0.5, yielding a maximum coefficient of determination ( R 2 ) of 0.9103 and a significantly reduced tracking error compared to baseline unscaled configurations. Furthermore, the parameterized gating architecture accelerates training convergence velocity by up to 45% while maintaining strict stability boundaries within a range of. These key numerical findings prove the structural effectiveness and universality of the proposed framework, establishing it as a highly accurate, computationally efficient solution suitable for online deployment in real-time electric vehicle battery management systems.

  • Data-Driven Detection of False Data Injection Attacks in Smart Grids using Self-Attention Enabled Conditional GAN with Gradient Penalty

    by Murugesan S, Ramjethmalani C H, Navin Sam K, Venkadesan A, Sadheesh Kumar S J

    The increasing integration of advanced information and communication technologies in power systems has increased their vulnerability to cyberattacks. False Data Injection Attacks (FDIAs) are a concerning and widely encountered cyberattack. FDIAs pose a critical threat to the security and reliability of modern power systems by manipulating measurement data. Traditional state estimation techniques often fail to detect stealthy FDIAs, particularly in large-scale grids. This paper proposes a Self-Attention-enabled Conditional Generative Adversarial Network with Gradient Penalty (SACGAN-GP) for effective FDIA detection. The framework leverages a self-attention mechanism to capture long-range dependencies among state variables, enhancing feature representation and improving detection performance. The gradient penalty term ensures training stability and mitigates mode collapse, a common issue in standard GANs. SACGAN-GP can effectively utilize limited labelled attack data and learn robust representations of normal and anomalous patterns, without relying heavily on large, labelled datasets as required by supervised models. Experimental validation on IEEE 14-bus and 118-bus test systems demonstrates that the proposed model performs better than other methods. The proposed method achieves an accuracy of 97.06%, F1-score of 98.28%, and an AUC of 100% on the IEEE 14-bus system, while attaining 95.59% accuracy, 97.39% F1-score, and 100% AUC on the IEEE 118-bus system. Detection times remain under 0.52 seconds, confirming the methods applicability for real-time scenarios. Furthermore, attention heatmaps generated by the model provide interpretable insights into the localized impacts of FDIAs, offering a promising direction for intelligent, secure power grid monitoring.


  • Enhancing legacy OLTC performance through Cost-effective retrofitting: a field-tested approach

    by Sadheesh Kumar S. Jayaraman, Ram Jethmalani C. Hemparuva, Navin Sam Kamaraj

    Legacy On-Load Tap Changer (OLTC) systems in distribution substations are often vulnerable to phase reversal errors, voltage fluctuations, and mechanical degradation, particularly in resource-constrained environments. These challenges degrade voltage regulation accuracy and accelerate wear in OLTC components due to excessive or incorrect tap operations. This paper presents a cost-effective retrofit control strategy designed to enhance the reliability and performance of mechanical OLTC systems. The proposed solution integrates real-time phase sequence detection, adaptive tap control logic using hysteresis thresholds, and automatic motor direction correction to prevent erroneous tap movements. A comprehensive MATLAB-based simulation validates the methodology under various operational scenarios, including reverse power flow, phase reversal, and voltage sags/swells. The strategy is also experimentally deployed in a live 11 kV/433 V university distribution substation. It covers diverse loads such as administrative cum academic blocks, laboratories, guest house cum hostels, and HVAC systems. In this university campus scenario, it demonstrates a 66 % reduction in tap changes, enhanced Mean Time Between Failures (MTBF), and 80 % fewer manual interventions. The outcomes confirm that the proposed retrofit enhances voltage stability, operational efficiency, and system longevity, making it a scalable and economically viable solution for ageing power distribution infrastructure.