ICIuliana Corneschi

Iuliana Corneschi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iuliana Corneschi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Alexandru Stere

    Faculty of Materials Science and Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei Street, 060042 Bucharest, Romania

    1 shared publication
  • Florin Miculescu

    Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 011061 Bucharest, Romania

    1 shared publication
  • Ioana Dana Carstoc

    Faculty of Medicine, University Lucian Blaga of Sibiu, 2A Lucian Blaga Street, 550169 Sibiu, Romania

    1 shared publication
  • Iulian Antoniac

    Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania

    1 shared publication
  • Larisa Popescu

    Faculty of Materials Science and Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei Street, 060042 Bucharest, Romania

    1 shared publication
  • Razvan Adam

    Orthopedic Department, Clinical University Emergency Hospital Elias, 011461 Bucharest, Romania

    1 shared publication

Latest Publications

  • Open Access

    Cementation and Interface Analysis by Different Microscopically Techniques of Failure Cases After BHR Arthroplasty

    by Razvan Adam, Iulian Antoniac, Adam Stuparu Andreea Minodora, Iuliana Corneschi, Larisa Popescu, Alexandru Stere, Sergiu Focsaneanu, Florin Miculescu, Ioana Dana Carstoc

    Birmingham hip resurfacing (BHR) is an alternative to bone-sparing total hip arthroplasty; however, failures may be associated with the cementing technique. This study aimed to evaluate the characteristics of the cement layer and potential failure mechanisms. BHR explants were analyzed using radiographic evaluation, stereomicroscopy, scanning electron microscopy (SEM), and histopathology. The cement layer was nonuniform, with excessive thickness in the dome regions and insufficient lateral coverage. Increased cement penetration values exceeded recommended thresholds. SEM analysis revealed inhomogeneous cement with cracks, air inclusions, and loosening at the cement–prosthesis interface. BHR failure may be associated with a complex interplay between cementation parameters, cement mantle morphology, and the biological response at the bone–cement interface, as well as interactions at the cement–prosthesis interface. Microscopic evaluation may provide valuable insights into the mechanisms potentially contributing to BHR prosthesis failure.