Kazuhiro Agatsuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kazuhiro Agatsuma has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Kazuaki Kuroda
Institute for Cosmic Ray Research University of Tokyo 277-8582 Kashiwa Chiba Japan
2 shared publicationsKazuhiro Yamamoto
Institut für Gravitationsphysik Max-Planck-Institut für Gravitationsphysik Albert-Einstein-Institut) Leibniz Universität Hannover Callinstraße 38 D-30167 Hannover Germany
2 shared publicationsMasatake Ohashi
Institute for Cosmic Ray Research University of Tokyo 277-8582 Kashiwa Chiba Japan
2 shared publicationsOsamu Miyakawa
Institute for Cosmic Ray Research University of Tokyo 277-8582 Kashiwa Chiba Japan
2 shared publicationsSeiji Kawamura
National Astronomical Observatory of Japan 181-8588 Mitaka Tokyo Japan
2 shared publicationsShinji Miyoki
Institute for Cosmic Ray Research University of Tokyo 277-8582 Kashiwa Chiba Japan
2 shared publications
Latest Publications
- Open Access
Thermal-noise-limited underground interferometer CLIO
We report on the current status of CLIO (Cryogenic Laser Interferometer Observatory), which is a prototype interferometer for LCGT (Large Scale Cryogenic Gravitational-Wave Telescope). LCGT is a Japanese next-generation interferometric gravitational wave detector featuring the use of cryogenic mirrors and a quiet underground site. The main purpose of CLIO is to demonstrate a reduction of the mirror thermal noise by cooling the sapphire mirrors. CLIO is located in an underground site of the Kamioka mine, 1000 m deep from the mountain top, to verify its advantages. After a few years of commissioning work, we have achieved a thermal-noise-limited sensitivity at room temperature. One of the main results of noise hunting was the elimination of thermal noise caused by a conductive coil-holder coupled with a pendulum through magnets.
Open AccessThermal-noise-limited underground interferometer CLIO
We report on the current status of CLIO (Cryogenic Laser Interferometer Observatory), which is a prototype interferometer for LCGT (Large Scale Cryogenic Gravitational-Wave Telescope). LCGT is a Japanese next-generation interferometric gravitational wave detector featuring the use of cryogenic mirrors and a quiet underground site. The main purpose of CLIO is to demonstrate a reduction of the mirror thermal noise by cooling the sapphire mirrors. CLIO is located in an underground site of the Kamioka mine, 1000 m deep from the mountain top, to verify its advantages. After a few years of commissioning work, we have achieved a thermal-noise-limited sensitivity at room temperature. One of the main results of noise hunting was the elimination of thermal noise caused by a conductive coil-holder coupled with a pendulum through magnets.
- Open Access
Direct Measurement of Thermal Fluctuation of High-Q Pendulum
We achieved for the first time a direct measurement of the thermal fluctuation of a pendulum in an off-resonant region using a laser interferometric gravitational wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which was derived by a fluctuation-dissipation theorem. Thermal fluctuation is dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 10^5 of the pendulum.
Open AccessDirect Measurement of Thermal Fluctuation of High-Q Pendulum
We achieved for the first time a direct measurement of the thermal fluctuation of a pendulum in an off-resonant region using a laser interferometric gravitational wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which was derived by a fluctuation-dissipation theorem. Thermal fluctuation is dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 10^5 of the pendulum.