Aysha Hasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aysha Hasan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abdelrahman M. Tawfik
Faculty of Medicine, Alexandria University, Alexandria, Egypt
1 shared publication - Ahmed Bostamy Elsnhory
Faculty of Medicine, Al-Azhar University, Cairo, Egypt
1 shared publication - Amira A. Aboali
Department of Diagnostic and Interventional Radiology, Damanhour Teaching Hospital, General Organization for Teaching Hospitals and Institutes, Damanhour, Egypt
1 shared publication - Christopher Hugh McClean
Department of Radiology, Aultman Hospital, Canton, Ohio, United States of America
1 shared publication - Eslam Abady
Faculty of Medicine, Tanta University, Tanta, Egypt
1 shared publication - Khaled Abouelmagd
Cardiology Department, Faculty of Medicine, Al-Azhar University, New Damietta, Egypt
1 shared publication
Latest Publications
- Open Access
- 13 February 2026
- Published by Jaypee Brothers Medical Publishing in Indian Journal of Critical Care Medicine
- Vol. 30 (2) , 155-164
Diagnostic Accuracy of Point-of-care Ultrasonography for Confirming Endotracheal Tube Placement in Adults: An Updated Systematic Review and Meta-analysis
Point-of-care ultrasonography (POCUS) is increasingly used to confirm endotracheal tube (ETT) placement; however, its overall diagnostic accuracy and speed compared with standard methods in adult emergency and critical care settings remain uncertain. We conducted a systematic review and meta-analysis of observational studies through May 2025 that evaluated POCUS for confirming ETT placement in adults (≥18 years) in emergency departments (EDs) and intensive care units (ICUs). Thirty studies met the inclusion criteria. Point-of-care ultrasonography achieved a pooled sensitivity of 0.91 and a specificity of 0.98. The area under the curve (AUC) was 0.96 [95% confidence interval (CI): 0.88–1.00]. The mean time-to-confirmation was 19.62 seconds for POCUS vs 22.46 seconds for standard methods; however, this finding should be interpreted with caution due to extreme heterogeneity (I² > 99%). Point-of-care ultrasonography is a highly accurate, rapid, and reliable method for confirming ETT placement in adult ED and ICU settings. It demonstrates diagnostic performance comparable to previously reported capnography performance and provides unique advantages as an adjunctive tool, especially in scenarios where capnography may be unreliable. Alsabri M, Elsnhory AB, Hasan MT, McClean CH, Abouelmagd K, Abady E, et al. Diagnostic Accuracy of Point-of-care Ultrasonography for Confirming Endotracheal Tube Placement in Adults: An Updated Systematic Review and Meta-analysis. Indian J Crit Care Med 2026;30(2):155–164.
- 13 February 2026
- Published by Jaypee Brothers Medical Publishing in Indian Journal of Critical Care Medicine
- Vol. 30 (2) , 155-164
Open AccessDiagnostic Accuracy of Point-of-care Ultrasonography for Confirming Endotracheal Tube Placement in Adults: An Updated Systematic Review and Meta-analysis
Point-of-care ultrasonography (POCUS) is increasingly used to confirm endotracheal tube (ETT) placement; however, its overall diagnostic accuracy and speed compared with standard methods in adult emergency and critical care settings remain uncertain. We conducted a systematic review and meta-analysis of observational studies through May 2025 that evaluated POCUS for confirming ETT placement in adults (≥18 years) in emergency departments (EDs) and intensive care units (ICUs). Thirty studies met the inclusion criteria. Point-of-care ultrasonography achieved a pooled sensitivity of 0.91 and a specificity of 0.98. The area under the curve (AUC) was 0.96 [95% confidence interval (CI): 0.88–1.00]. The mean time-to-confirmation was 19.62 seconds for POCUS vs 22.46 seconds for standard methods; however, this finding should be interpreted with caution due to extreme heterogeneity (I² > 99%). Point-of-care ultrasonography is a highly accurate, rapid, and reliable method for confirming ETT placement in adult ED and ICU settings. It demonstrates diagnostic performance comparable to previously reported capnography performance and provides unique advantages as an adjunctive tool, especially in scenarios where capnography may be unreliable. Alsabri M, Elsnhory AB, Hasan MT, McClean CH, Abouelmagd K, Abady E, et al. Diagnostic Accuracy of Point-of-care Ultrasonography for Confirming Endotracheal Tube Placement in Adults: An Updated Systematic Review and Meta-analysis. Indian J Crit Care Med 2026;30(2):155–164.