Myungbo Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Myungbo Kim has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Tzahi Cohen-Karni
Carnegie Mellon University
2 shared publications Carmel Majidi
Department of Mechanical Engineering Carnegie Mellon University Pittsburgh Pennsylvania USA
1 shared publication- Chunghwan Kim
Carnegie Mellon University
1 shared publication - Han Kim
Department of Biomedical Engineering, Carnegie Mellon University 1 , Pittsburgh, Pennsylvania 15213
1 shared publication Hanlin Cao
Carnegie Mellon University
1 shared publication- Karl Bates
Department of Biomedical Engineering Carnegie Mellon University Pittsburgh Pennsylvania USA
1 shared publication
Latest Publications
- Open Access
Predicting Macroscopic Axon Topology from Microscopic Kinematics: An Interactive Tracking and Random Walk Pipeline for Substrate-Dependent Cortical Neurospheres
The cortical neuron is a fundamental building block of the mammalian brain, and the morphology of its axonal projections is central to how functional circuits assemble. The trajectory along which an axon grows is a key determinant of connectivity, yet the kinematics of cortical axon outgrowth remain poorly quantified. Characterizing these dynamics is most tractable in vitro, where axonal growth can be measured directly and under controlled, reproducible conditions. Even in culture, however, this remains challenging because cortical neurons require dense plating for viability, and their soma is motile, so growth behavior is highly sensitive to local density and population context, complicating reproducible measurement of intrinsic dynamics. To overcome these limitations, we used size-controlled cortical neurospheres, which provide a fixed spatial origin and a reproducible environment, together with a custom semi-automated tracking pipeline to quantify single-axon kinematics across two functionalized substrates and two developmental phases. This approach revealed a substrate-dependent divergence in outgrowth: during the later developmental phase, axons on poly-D-lysine with laminin (PDL-LA) substrate grew faster than those on PDL, with a mean step size of 0.436 versus 0.339 $\mu$m /min. Decomposing trajectories into Katz dynamic states, we built a generative biased random walk model that reproduces axonal behavior at both microscopic (single-axon) and macroscopic (network topology) scales. This open, reproducible framework links single-axon kinematics to network architecture, enabling the structural connectivity of neurosphere-based circuits in vitro to be predicted from measurable growth dynamics, a necessary foundation for future studies linking circuit structure to emergent function.
Open AccessPredicting Macroscopic Axon Topology from Microscopic Kinematics: An Interactive Tracking and Random Walk Pipeline for Substrate-Dependent Cortical Neurospheres
The cortical neuron is a fundamental building block of the mammalian brain, and the morphology of its axonal projections is central to how functional circuits assemble. The trajectory along which an axon grows is a key determinant of connectivity, yet the kinematics of cortical axon outgrowth remain poorly quantified. Characterizing these dynamics is most tractable in vitro, where axonal growth can be measured directly and under controlled, reproducible conditions. Even in culture, however, this remains challenging because cortical neurons require dense plating for viability, and their soma is motile, so growth behavior is highly sensitive to local density and population context, complicating reproducible measurement of intrinsic dynamics. To overcome these limitations, we used size-controlled cortical neurospheres, which provide a fixed spatial origin and a reproducible environment, together with a custom semi-automated tracking pipeline to quantify single-axon kinematics across two functionalized substrates and two developmental phases. This approach revealed a substrate-dependent divergence in outgrowth: during the later developmental phase, axons on poly-D-lysine with laminin (PDL-LA) substrate grew faster than those on PDL, with a mean step size of 0.436 versus 0.339 $\mu$m /min. Decomposing trajectories into Katz dynamic states, we built a generative biased random walk model that reproduces axonal behavior at both microscopic (single-axon) and macroscopic (network topology) scales. This open, reproducible framework links single-axon kinematics to network architecture, enabling the structural connectivity of neurosphere-based circuits in vitro to be predicted from measurable growth dynamics, a necessary foundation for future studies linking circuit structure to emergent function.
- Open Access
- 23 March 2026
- Published by Wiley in Advanced Electronic Materials
- Vol. 12 (14) , e00885
Chronic Disease Monitoring Using Advanced Compliant Materials for Bioelectronics
Chronic disease arises slowly through complex physiological factors that require continuous monitoring and treatment. Compliant bioelectronics with soft, stretchable, and tissue‐conformal designs allow for in vivo continuous monitoring through electrophysiological, mechanical, and biochemical modalities, while minimizing tissue irritation and immune system response. In this review, we discuss recent progress in material development, device design, and versatile sensing modalities that allow stable long‐term operation in dynamic biological environments. We focus on chronic electrophysiological systems for neural and cardiac recording, mechanical sensing systems for strain and pressure, and electrochemical sensors for molecular biomarkers. In addition, we examine self‐powered bioelectronics based on piezoelectric and triboelectric energy conversion mechanisms that eliminate the requirement for external batteries, whereas multimodal and closed‐loop systems combine sensing with therapeutic feedback. We consider key parameters like material biocompatibility, device flexibility, and long‐term stability that are required for chronic monitoring to maintain stable signal quality over long time periods relevant for clinical recordings. These technologies for compliant bioelectronics enable early disease diagnosis, personalized treatment and continuous intervention for patients, narrowing the gap between laboratory study and routine clinical applications.
- 23 March 2026
- Published by Wiley in Advanced Electronic Materials
- Vol. 12 (14) , e00885
Open AccessChronic Disease Monitoring Using Advanced Compliant Materials for Bioelectronics
Chronic disease arises slowly through complex physiological factors that require continuous monitoring and treatment. Compliant bioelectronics with soft, stretchable, and tissue‐conformal designs allow for in vivo continuous monitoring through electrophysiological, mechanical, and biochemical modalities, while minimizing tissue irritation and immune system response. In this review, we discuss recent progress in material development, device design, and versatile sensing modalities that allow stable long‐term operation in dynamic biological environments. We focus on chronic electrophysiological systems for neural and cardiac recording, mechanical sensing systems for strain and pressure, and electrochemical sensors for molecular biomarkers. In addition, we examine self‐powered bioelectronics based on piezoelectric and triboelectric energy conversion mechanisms that eliminate the requirement for external batteries, whereas multimodal and closed‐loop systems combine sensing with therapeutic feedback. We consider key parameters like material biocompatibility, device flexibility, and long‐term stability that are required for chronic monitoring to maintain stable signal quality over long time periods relevant for clinical recordings. These technologies for compliant bioelectronics enable early disease diagnosis, personalized treatment and continuous intervention for patients, narrowing the gap between laboratory study and routine clinical applications.