Bernardo Moguel-Gonzáles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bernardo Moguel-Gonzáles has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Antoni N. Osorio Mendoza
Department of Nephrology, Hospital Cayetano Heredia, Lima 15002, Peru
1 shared publication - Avinash Chandu Nanwani
Department of Nephrology, Hospital General de Fuerteventura, 35600 Fuerteventura, Spain
1 shared publication - Brenda Guadalupe Cortez-Flores
Instituto Nacional de Cardiología Ignacio Chavez Department of Nephrology Mexico City
1 shared publication - Carlos Cruzado Pizarro
Department of Nephrology, Hospital Nacional Ramiro Prialé, Huancayo 12006, Peru
1 shared publication - Carlos Narváez-Mejia
Department of Nephrology, Hospital Universitario Puerta del Mar, 11009 Cádiz, Spain
1 shared publication - Celia Rodríguez Tudero
Department of Nephrology, Hospital Universitario de Salamanca, 37007 Salamanca, Spain
1 shared publication
Latest Publications
- Open Access
Ultrasound-Guided Placement of Tunneled Hemodialysis Catheters Using Direct Atrial Visualization: Clinical and Functional Results at One Year Follow-Up
Background and Objectives: Ultrasound-guided placement of tunneled hemodialysis catheters may be useful when fluoroscopy is unavailable or radiation exposure should be avoided. This study describes a technique based on direct ultrasound visualization of the metallic guidewire within the right atrium and evaluates one-year clinical and functional outcomes. Materials and Methods: We conducted a single-center retrospective observational study of 319 adult hemodialysis patients undergoing tunneled catheter placement. The technique combined intravascular guidewire length measurement with subcostal ultrasound visualization of the guidewire tip in the right atrium. Baseline characteristics, insertion site, immediate complications, blood flow rate, Kt/V, and extracorporeal circuit pressures were analyzed. Results: Mean age was 55.9 ± 14.5 years, and 58.6% were women. The main causes of chronic kidney disease were diabetes mellitus and arterial hypertension. Mean blood flow rate was 349 mL/min at 3 months and 357 mL/min at 12 months. Mean Kt/V at 12 months was 1.57. No catheter malpositions requiring immediate repositioning were documented. Procedure-related complications were infrequent and mainly local. Conclusions: Ultrasound-guided tunneled catheter placement using direct visualization of the guidewire within the right atrium was technically feasible and associated with favorable functional parameters and few immediate complications. Given the retrospective design and lack of a comparative group, these findings should be interpreted with caution. Prospective comparative studies are needed to confirm safety, reproducibility, and clinical utility.
Open AccessUltrasound-Guided Placement of Tunneled Hemodialysis Catheters Using Direct Atrial Visualization: Clinical and Functional Results at One Year Follow-Up
Background and Objectives: Ultrasound-guided placement of tunneled hemodialysis catheters may be useful when fluoroscopy is unavailable or radiation exposure should be avoided. This study describes a technique based on direct ultrasound visualization of the metallic guidewire within the right atrium and evaluates one-year clinical and functional outcomes. Materials and Methods: We conducted a single-center retrospective observational study of 319 adult hemodialysis patients undergoing tunneled catheter placement. The technique combined intravascular guidewire length measurement with subcostal ultrasound visualization of the guidewire tip in the right atrium. Baseline characteristics, insertion site, immediate complications, blood flow rate, Kt/V, and extracorporeal circuit pressures were analyzed. Results: Mean age was 55.9 ± 14.5 years, and 58.6% were women. The main causes of chronic kidney disease were diabetes mellitus and arterial hypertension. Mean blood flow rate was 349 mL/min at 3 months and 357 mL/min at 12 months. Mean Kt/V at 12 months was 1.57. No catheter malpositions requiring immediate repositioning were documented. Procedure-related complications were infrequent and mainly local. Conclusions: Ultrasound-guided tunneled catheter placement using direct visualization of the guidewire within the right atrium was technically feasible and associated with favorable functional parameters and few immediate complications. Given the retrospective design and lack of a comparative group, these findings should be interpreted with caution. Prospective comparative studies are needed to confirm safety, reproducibility, and clinical utility.
- Open Access
- 18 March 2026
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 19 (5)
Safety and feasibility of initiating peritoneal dialysis within 24 hours after percutaneous versus surgical catheter placement
End-stage kidney disease (ESKD) is a rising global health challenge. Despite superior quality of life and cost-effectiveness, only 11% of patients initiate renal replacement therapy with peritoneal dialysis (PD), primarily due to the traditional extended break-in period. Recent advancements in percutaneous catheter placement have facilitated urgent-start and early-start PD protocols. This study compared the break-in period (immediate-start PD (p < 0.001). Percutaneous techniques represented 97% of the break-in periods within 6 hours, whereas minilaparotomy accounted for 91% of the break-in periods between 25 and 72 hours. Complications affected 30% of the patients overall, with mechanical issues (23%) predominating, including outflow failure (19%) and catheter migration (9.1%), with no differences observed between techniques (p = 0.9, p = 0.8). The rate of repositioning was greater with the use of percutaneous methods (13–14% vs. 4%, p = 0.008). Infections were more common with minilaparotomy (14% vs. 7.4–8.3%, p = 0.12), with exit-site infections (8.1% vs. 1.4–2.2%, p = 0.006) and tunnelitis (6.0% vs. 0.7–2.8%, p = 0.041) exhibiting significance. Mini-laparotomy increased the risk of infection (OR 2.13, 95% CI 1.02–4.44; p = 0.043). Immediate-start PD, defined as initiation within 24 hours of catheter placement, is safe and feasible. These findings support the expansion of nephrologist training in percutaneous placement.
- 18 March 2026
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 19 (5)
Open AccessSafety and feasibility of initiating peritoneal dialysis within 24 hours after percutaneous versus surgical catheter placement
End-stage kidney disease (ESKD) is a rising global health challenge. Despite superior quality of life and cost-effectiveness, only 11% of patients initiate renal replacement therapy with peritoneal dialysis (PD), primarily due to the traditional extended break-in period. Recent advancements in percutaneous catheter placement have facilitated urgent-start and early-start PD protocols. This study compared the break-in period (immediate-start PD (p < 0.001). Percutaneous techniques represented 97% of the break-in periods within 6 hours, whereas minilaparotomy accounted for 91% of the break-in periods between 25 and 72 hours. Complications affected 30% of the patients overall, with mechanical issues (23%) predominating, including outflow failure (19%) and catheter migration (9.1%), with no differences observed between techniques (p = 0.9, p = 0.8). The rate of repositioning was greater with the use of percutaneous methods (13–14% vs. 4%, p = 0.008). Infections were more common with minilaparotomy (14% vs. 7.4–8.3%, p = 0.12), with exit-site infections (8.1% vs. 1.4–2.2%, p = 0.006) and tunnelitis (6.0% vs. 0.7–2.8%, p = 0.041) exhibiting significance. Mini-laparotomy increased the risk of infection (OR 2.13, 95% CI 1.02–4.44; p = 0.043). Immediate-start PD, defined as initiation within 24 hours of catheter placement, is safe and feasible. These findings support the expansion of nephrologist training in percutaneous placement.