Oleg Bugai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oleg Bugai has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Danil Dmitrievich Kazimirov
Institute for Information Transmission Problems of the Russian Academy of Sciences, 127051 Moscow, Russia
3 shared publications - Dmitrii P. Nikolaev
Federal Research Center “Computer Science and Control” of the Russian Academy of Sciences, Moscow 119333, Russia
3 shared publications - Marat Gilmanov
Institute for Information Transmission Problems of the Russian Academy of Sciences, 127051 Moscow, Russia
3 shared publications - Andrey Kirkicha
Smart Engines Service LLC, 117312 Moscow, Russia
2 shared publications - Dmitry Polevoy
Federal Research Center Computer Science and Control RAS, 119333 Moscow, Russia
2 shared publications - Leonid Koliaskin
Smart Engines Service LLC, 117312 Moscow, Russia
2 shared publications
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in Tomography
- Vol. 12 (12) , 167
X-SLAM: A Novel Freehand Portable X-Ray Computed Tomography Technology
Background: Computed tomography (CT) is an essential tool in modern medical imaging, but conventional CT systems rely on immobile gantry-based hardware and tightly constrained acquisition geometry, limiting their use in emergency, field, and point-of-care scenarios where rapid on-site imaging is required. Methods: To address this limitation, we propose X-SLAM, a freehand portable low-dose CT technology that eliminates mechanical positioning systems and enables projection data acquisition using a manually moved X-ray source and a mobile flat-panel detector. Unlike conventional CT, X-SLAM does not enforce predefined scanning trajectories. Instead, it estimates the unknown and a priori arbitrary acquisition geometry simultaneously with acquisition using a freely positioned calibration anchor object. We present the full realization of X-SLAM, including setup and acquisition protocol design, a solution for automatic geometry self-estimation, and an implementation of an extremely sparse-view reconstruction algorithm. Results: Experimental evaluation of the accuracy of the localization of small metallic objects is performed in varying experimental conditions, and the maximum relative localization error is estimated to be <3 mm for objects of diameter 3 mm. X-SLAM enables a compact, suitcase-scale realization of a tomographic system, providing the potential to achieve 3D diagnostics in out-of-hospital scenarios. The proposed method operates without GPUs or cloud computing and can be executed on standard consumer devices such as laptops or tablets within minutes, which is important for portability and autonomy of the device. Conclusions: Proof-of-concept experiments demonstrate the feasibility of freehand CT acquisition and volumetric reconstruction on the basis of X-SLAM technology.
- 24 November 2026
- Published by MDPI AG in Tomography
- Vol. 12 (12) , 167
Open AccessX-SLAM: A Novel Freehand Portable X-Ray Computed Tomography Technology
Background: Computed tomography (CT) is an essential tool in modern medical imaging, but conventional CT systems rely on immobile gantry-based hardware and tightly constrained acquisition geometry, limiting their use in emergency, field, and point-of-care scenarios where rapid on-site imaging is required. Methods: To address this limitation, we propose X-SLAM, a freehand portable low-dose CT technology that eliminates mechanical positioning systems and enables projection data acquisition using a manually moved X-ray source and a mobile flat-panel detector. Unlike conventional CT, X-SLAM does not enforce predefined scanning trajectories. Instead, it estimates the unknown and a priori arbitrary acquisition geometry simultaneously with acquisition using a freely positioned calibration anchor object. We present the full realization of X-SLAM, including setup and acquisition protocol design, a solution for automatic geometry self-estimation, and an implementation of an extremely sparse-view reconstruction algorithm. Results: Experimental evaluation of the accuracy of the localization of small metallic objects is performed in varying experimental conditions, and the maximum relative localization error is estimated to be <3 mm for objects of diameter 3 mm. X-SLAM enables a compact, suitcase-scale realization of a tomographic system, providing the potential to achieve 3D diagnostics in out-of-hospital scenarios. The proposed method operates without GPUs or cloud computing and can be executed on standard consumer devices such as laptops or tablets within minutes, which is important for portability and autonomy of the device. Conclusions: Proof-of-concept experiments demonstrate the feasibility of freehand CT acquisition and volumetric reconstruction on the basis of X-SLAM technology.
- Open Access
- 18 November 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (11) , 581
STAMM3D: Dataset and Benchmark for Non-Deformable 3D Image Registration in Multiple Modalities
Volumetric image registration is a fundamental computer vision problem with broad applications across fields such as medicine, biological and cellular imaging, geoscience, and cultural heritage preservation. The 3D image registration problem is commonly divided into monomodal and multimodal registration problems, depending on whether the images originate from the same or different imaging modalities. Monomodal 3D image registration is a well-studied problem with established state-of-the-art methods and a range of widely recognized benchmarks. In contrast, multimodal 3D image registration remains an open problem despite numerous developed registration methods. A key challenge is that existing open-access multimodal benchmark datasets are scarce and limited in modality diversity, which constrains registration generalization across modalities. As a result, most multimodal registration methods remain tuned to specific modalities and narrow domains of objects. This leads to the need to redevelop multimodal registration tools for each specific task, and no universal solution exists. To approach the task of universal multimodal image registration, in this paper we introduce STAMM3D (Similarity Transform Alignment of Multimodal 3D images)—a new benchmark for multimodal registration that includes an open-access dataset of 22 3D images of rigid medical, biological, and non-biomedical objects and provides an automated Target Registration Error-based evaluation framework. The publicly availablebenchmark offers a high-resolution dataset with multiple domains of objects and a wide range of different modalities deliberately chosen to test and compare universality and generalization properties of the registration methods. The focus of the dataset is on non-deformable image registration since it directly affects the quality of image fusion, whether used independently or within multi-stage deformable registration pipelines. Using STAMM3D, we benchmark several widespread, multipurpose, open-source non-deformable registration tools (NiftyReg, SimpleITK, SIFT3D, DeedsBCV), establishing a solid performance baseline. While existing tools provide a solid baseline, the comparison results suggest that additional work is needed to improve the robustness of non-deformable registration techniques.
- 18 November 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (11) , 581
Open AccessSTAMM3D: Dataset and Benchmark for Non-Deformable 3D Image Registration in Multiple Modalities
Volumetric image registration is a fundamental computer vision problem with broad applications across fields such as medicine, biological and cellular imaging, geoscience, and cultural heritage preservation. The 3D image registration problem is commonly divided into monomodal and multimodal registration problems, depending on whether the images originate from the same or different imaging modalities. Monomodal 3D image registration is a well-studied problem with established state-of-the-art methods and a range of widely recognized benchmarks. In contrast, multimodal 3D image registration remains an open problem despite numerous developed registration methods. A key challenge is that existing open-access multimodal benchmark datasets are scarce and limited in modality diversity, which constrains registration generalization across modalities. As a result, most multimodal registration methods remain tuned to specific modalities and narrow domains of objects. This leads to the need to redevelop multimodal registration tools for each specific task, and no universal solution exists. To approach the task of universal multimodal image registration, in this paper we introduce STAMM3D (Similarity Transform Alignment of Multimodal 3D images)—a new benchmark for multimodal registration that includes an open-access dataset of 22 3D images of rigid medical, biological, and non-biomedical objects and provides an automated Target Registration Error-based evaluation framework. The publicly availablebenchmark offers a high-resolution dataset with multiple domains of objects and a wide range of different modalities deliberately chosen to test and compare universality and generalization properties of the registration methods. The focus of the dataset is on non-deformable image registration since it directly affects the quality of image fusion, whether used independently or within multi-stage deformable registration pipelines. Using STAMM3D, we benchmark several widespread, multipurpose, open-source non-deformable registration tools (NiftyReg, SimpleITK, SIFT3D, DeedsBCV), establishing a solid performance baseline. While existing tools provide a solid baseline, the comparison results suggest that additional work is needed to improve the robustness of non-deformable registration techniques.
- 1 July 2025
- Published by Pleiades Publishing Ltd in Journal of Communications Technology and Electronics
- Vol. 70 (7) , 342-359
3D Hough Transform-Based Automatic Orthotropic Alignment of Volumetric Images
Orthotropic alignment of 3D images refers to setting a volume’s orientation according to its orthotropic properties. It is particularly important in industrial computed tomography (CT), where alignment enables standardized orientation of similar objects, facilitating registration, including CAD-model registration, for precise defect measurement. Orthotropic alignment is critical in applications such as printed circuit board (PCB) inspection and analysis of complex components, e.g., measuring engine blade clearances. In the latter case, slices must align with specific anisotropic axes, which may not fully correspond to orthotropic properties, representing another practical scenario. Existing orthotropic alignment methods, however, suffer from limited accuracy and applicability. In this paper, we formalize the task and propose a robust, efficient, reproducible, fully automatic approach for aligning various volumes. Our method leverages a 3D fast Hough transform (FHT) to compute sums across a set of planes, enabling reliable detection of anisotropic axes and orthotropic features. The FHT has been successfully applied in 2D image processing and document recognition; here, extended to three dimensions, it serves as an effective tool for orthotropic alignment. While a naive implementation would require O(N5) operations, the 3D FHT reduces this to O(N3 log N), making it comparable with classical tensor-based approaches. We provide the implementation, evaluation, and assessment of the algorithm on both real and synthetic CT data. The results outperform baseline methods in both quality and robustness, while offering broader applicability and fewer optimization parameters. Potential applications in related fields are also discussed.
- 1 July 2025
- Published by Pleiades Publishing Ltd in Journal of Communications Technology and Electronics
- Vol. 70 (7) , 342-359
3D Hough Transform-Based Automatic Orthotropic Alignment of Volumetric Images
Orthotropic alignment of 3D images refers to setting a volume’s orientation according to its orthotropic properties. It is particularly important in industrial computed tomography (CT), where alignment enables standardized orientation of similar objects, facilitating registration, including CAD-model registration, for precise defect measurement. Orthotropic alignment is critical in applications such as printed circuit board (PCB) inspection and analysis of complex components, e.g., measuring engine blade clearances. In the latter case, slices must align with specific anisotropic axes, which may not fully correspond to orthotropic properties, representing another practical scenario. Existing orthotropic alignment methods, however, suffer from limited accuracy and applicability. In this paper, we formalize the task and propose a robust, efficient, reproducible, fully automatic approach for aligning various volumes. Our method leverages a 3D fast Hough transform (FHT) to compute sums across a set of planes, enabling reliable detection of anisotropic axes and orthotropic features. The FHT has been successfully applied in 2D image processing and document recognition; here, extended to three dimensions, it serves as an effective tool for orthotropic alignment. While a naive implementation would require O(N5) operations, the 3D FHT reduces this to O(N3 log N), making it comparable with classical tensor-based approaches. We provide the implementation, evaluation, and assessment of the algorithm on both real and synthetic CT data. The results outperform baseline methods in both quality and robustness, while offering broader applicability and fewer optimization parameters. Potential applications in related fields are also discussed.