Wei-Ren Syong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei-Ren Syong has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Corey Rae Harrington McRae
Department of Physics, University of Colorado Boulder 4 , Boulder, Colorado 80309
2 shared publications - Douglas A. Bennett
National Institute of Standards and Technology
2 shared publications - Michael R. Vissers
National Institute of Standards and Technology
2 shared publications Allie Miller
Department of Electrical, Computer, and Energy Engineering, University of Colorado 2 , Boulder, Colorado 80309
1 shared publication- David A. Garcia Wetten
Department of Materials Science and Engineering, Northwestern University 1 , Evanston, Illinois 60208
1 shared publication - Dominic P. Goronzy
Northwestern University
1 shared publication
Latest Publications
- 22 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (25)
Comparison of Nb and Ta pentoxide loss tangents for superconducting quantum devices
Superconducting transmon qubits are commonly made with thin-film Nb wiring, but recent studies have shown increased performance with Ta wiring. In this work, we compare the resonator-induced single photon, millikelvin dielectric loss for pentoxides of Nb (Nb2O5) and Ta (Ta2O5) in order to further understand limiting losses in qubits. Nb and Ta pentoxides of three thicknesses are deposited via pulsed laser deposition onto nominally identical coplanar waveguide resonators. The two-level system loss tangent is determined to be 0.0064 (0.0035) for Nb2O5 (Ta2O5) for a dielectric constant of 10. This work indicates that qubits with Nb wiring are affected by higher loss arising from the native pentoxide itself, likely in addition to the presence of suboxides, which are largely absent in Ta.
- 22 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (25)
Comparison of Nb and Ta pentoxide loss tangents for superconducting quantum devices
Superconducting transmon qubits are commonly made with thin-film Nb wiring, but recent studies have shown increased performance with Ta wiring. In this work, we compare the resonator-induced single photon, millikelvin dielectric loss for pentoxides of Nb (Nb2O5) and Ta (Ta2O5) in order to further understand limiting losses in qubits. Nb and Ta pentoxides of three thicknesses are deposited via pulsed laser deposition onto nominally identical coplanar waveguide resonators. The two-level system loss tangent is determined to be 0.0064 (0.0035) for Nb2O5 (Ta2O5) for a dielectric constant of 10. This work indicates that qubits with Nb wiring are affected by higher loss arising from the native pentoxide itself, likely in addition to the presence of suboxides, which are largely absent in Ta.
- 16 March 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (11)
High-throughput microwave package for precise superconducting device measurement
Cryogenic microwave measurement of superconducting quantum devices is complicated by the packaging required to connect devices to control and read out circuitry. In this work, we outline the design and experimental demonstration of a wirebond-free, PCB-free, drop-in microwave package for on-chip superconducting quantum devices. Once a chip is prepared for installation, the proposed package enables device exchange in about 1 min, with no special equipment required. The package is composed of a superconducting aluminum enclosure with a suspended tungsten transmission pin which couples to on-chip resonators in a hanger-style geometry, enabling broadband transmission measurements without on-chip feedlines or wirebonds. The fundamental package cavity mode is far detuned from the 4 to 8 GHz band of interest and does not participate in resonator readout. We demonstrate the use of this package to extract the loss tangent of superconducting ring resonators, measuring a value of (1.10±0.09)×10−6, which agrees with measurements of λ/4 resonators in wirebond-based packaging. This high-throughput measurement system will allow the rapid generation of large datasets for improving superconducting qubit performance, and facilitate time-sensitive surface passivation and oxide regrowth studies.
- 16 March 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (11)
High-throughput microwave package for precise superconducting device measurement
Cryogenic microwave measurement of superconducting quantum devices is complicated by the packaging required to connect devices to control and read out circuitry. In this work, we outline the design and experimental demonstration of a wirebond-free, PCB-free, drop-in microwave package for on-chip superconducting quantum devices. Once a chip is prepared for installation, the proposed package enables device exchange in about 1 min, with no special equipment required. The package is composed of a superconducting aluminum enclosure with a suspended tungsten transmission pin which couples to on-chip resonators in a hanger-style geometry, enabling broadband transmission measurements without on-chip feedlines or wirebonds. The fundamental package cavity mode is far detuned from the 4 to 8 GHz band of interest and does not participate in resonator readout. We demonstrate the use of this package to extract the loss tangent of superconducting ring resonators, measuring a value of (1.10±0.09)×10−6, which agrees with measurements of λ/4 resonators in wirebond-based packaging. This high-throughput measurement system will allow the rapid generation of large datasets for improving superconducting qubit performance, and facilitate time-sensitive surface passivation and oxide regrowth studies.