Yu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Zhang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Leming Shi
Fudan University, China
2 shared publications - Lianhua Dong
Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, China
2 shared publications Yang Liu
Center for Advanced Measurement of Science , National Institute of Metrology , Beijing , China
2 shared publications- Yuanting Zheng
State Key Laboratory of Genetics and Development of Complex Phenotypes, School of Life Sciences and Human Phenome Institute, Fudan University, Shanghai, China
2 shared publications Bingwen Yang
Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, China
1 shared publication- Bo Wang
School of Automation Science and Engineering, Faculty of Electronic and Information Engineering, Xi’an Jiaotong University, Xi’an, China
1 shared publication
Latest Publications
- 7 May 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (9) , 1957-1965
Pseudovirus reference material and RT-digital PCR reference method for the quantification of human rhinovirus RNA with metrological traceability
Objectives: This study developed a pseudoviral human rhinovirus (HRV) reference material using pseudovirus technology and integrating RT-dPCR with HPLC-IDMS to achieve accurate HRV RNA quantification, aiming to standardize HRV detection across labs and platforms. Methods: We developed an RT-digital PCR (RT-dPCR) reference method for HRV, incorporating reverse transcription efficiency (RTE) correction using HPLC-isotope dilution mass spectrometry (HPLC-IDMS), which enables value assignment of the well-characterized pseudoviral reference material (RM) containing the conserved 5′UTR gene. Results: The developed RT-dPCR method demonstrated high analytical sensitivity with a limit of detection (LoD) of eight copies/reaction and a limit of quantification (LoQ) of 11 copies/reaction. RTE was accurately determined as 101.25 % using HPLC-IDMS, enabling metrologically traceable RNA quantification. The pseudoviral RM was characterized using the traceable RT-dPCR method; its reference value and expanded uncertainty were determined to be (3.12 ± 0.69) × 10 3 copies/μL (k=2). The RM exhibited sufficient homogeneity and stability for 12 months at −80 °C, and its non-infectious nature coupled with its ability to simulate the entire workflow including nucleic acid extraction offers significant advantages. Conclusions: This study provided essential tools for standardizing HRV detection across different laboratories and platforms. This work enables traceable RNA quantification in SI units and simulates the full analytical process, thereby enhancing the accuracy and comparability of results. Furthermore, this approach serves as a transferable model for developing reference materials and traceable quantification methods for other respiratory pathogens, contributing to advancements in molecular diagnostics and public health.
- 7 May 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (9) , 1957-1965
Pseudovirus reference material and RT-digital PCR reference method for the quantification of human rhinovirus RNA with metrological traceability
Objectives: This study developed a pseudoviral human rhinovirus (HRV) reference material using pseudovirus technology and integrating RT-dPCR with HPLC-IDMS to achieve accurate HRV RNA quantification, aiming to standardize HRV detection across labs and platforms. Methods: We developed an RT-digital PCR (RT-dPCR) reference method for HRV, incorporating reverse transcription efficiency (RTE) correction using HPLC-isotope dilution mass spectrometry (HPLC-IDMS), which enables value assignment of the well-characterized pseudoviral reference material (RM) containing the conserved 5′UTR gene. Results: The developed RT-dPCR method demonstrated high analytical sensitivity with a limit of detection (LoD) of eight copies/reaction and a limit of quantification (LoQ) of 11 copies/reaction. RTE was accurately determined as 101.25 % using HPLC-IDMS, enabling metrologically traceable RNA quantification. The pseudoviral RM was characterized using the traceable RT-dPCR method; its reference value and expanded uncertainty were determined to be (3.12 ± 0.69) × 10 3 copies/μL (k=2). The RM exhibited sufficient homogeneity and stability for 12 months at −80 °C, and its non-infectious nature coupled with its ability to simulate the entire workflow including nucleic acid extraction offers significant advantages. Conclusions: This study provided essential tools for standardizing HRV detection across different laboratories and platforms. This work enables traceable RNA quantification in SI units and simulates the full analytical process, thereby enhancing the accuracy and comparability of results. Furthermore, this approach serves as a transferable model for developing reference materials and traceable quantification methods for other respiratory pathogens, contributing to advancements in molecular diagnostics and public health.
- Open Access
- 26 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
A metrological foundation for absolute transcriptomics using International System of Units-anchored calibrators
RNA-sequencing's conversion of molecules to reads is inconsistent. Experiment-to-experiment variations (systemic bias) create batch effects, while gene-to-gene variations (sequence-dependent bias) invalidate inter-gene comparisons, precluding a universal scale. This confines analysis to relative fold-changes, a metric unreliable across batches. We introduce TranScale: 100 biomimetic standards with SI-traceable concentrations certified by Isotope Dilution Mass Spectrometry. Co-processed within samples, they empirically characterize systemic and sequence-dependent biases, generating a library-specific calibration curve (R² > 0.97) to convert reads into absolute quantities. This approach reveals that consistent fold-changes can mask severe absolute errors, exposing systemic biases missed by conventional QC. Across laboratories, this calibration reduced median inter-lab CV from >85% to 7.9, outperforming the widely-used tool ComBat. By anchoring RNA-seq to the SI, our work establishes the metrological foundation for data interoperability and universal benchmarks, enabling absolute comparisons of SI-traceable quantities between any two genes.
- 26 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessA metrological foundation for absolute transcriptomics using International System of Units-anchored calibrators
RNA-sequencing's conversion of molecules to reads is inconsistent. Experiment-to-experiment variations (systemic bias) create batch effects, while gene-to-gene variations (sequence-dependent bias) invalidate inter-gene comparisons, precluding a universal scale. This confines analysis to relative fold-changes, a metric unreliable across batches. We introduce TranScale: 100 biomimetic standards with SI-traceable concentrations certified by Isotope Dilution Mass Spectrometry. Co-processed within samples, they empirically characterize systemic and sequence-dependent biases, generating a library-specific calibration curve (R² > 0.97) to convert reads into absolute quantities. This approach reveals that consistent fold-changes can mask severe absolute errors, exposing systemic biases missed by conventional QC. Across laboratories, this calibration reduced median inter-lab CV from >85% to 7.9, outperforming the widely-used tool ComBat. By anchoring RNA-seq to the SI, our work establishes the metrological foundation for data interoperability and universal benchmarks, enabling absolute comparisons of SI-traceable quantities between any two genes.
- Open Access
- 26 November 2025
- Published by Oxford University Press (OUP) in Genomics, Proteomics & Bioinformatics
- Vol. 23 (6)
A Telomere-to-telomere Diploid Reference Genome and Centromere Structure of the Chinese Quartet
Recent advances in sequencing technologies have enabled the complete assembly of human genomes from telomere to telomere (T2T), resolving previously inaccessible regions such as centromeres and segmental duplications. Here, we present an updated, higher-quality, haplotype-phased T2T assembly of the Chinese Quartet (T2T-CQ), a family cohort comprising monozygotic twins and their parents, generated using high-coverage Oxford Nanopore Technologies (ONT) ultralong and PacBio high-fidelity (HiFi) sequencing. The T2T-CQ assembly serves as a crucial reference genome for integrating publicly available multi-omics data and advances the utility of the Quartet reference materials. The T2T-CQ assembly scores highly on multiple metrics of continuity and completeness, with Genome Continuity Inspector (GCI) scores of 77.76 (maternal) and 76.41 (paternal), 21-mer quality values (QVs) > 66, and Clipping Reveals Assembly Quality (CRAQ) scores > 99.6 for both haplotypes, enabling complete annotation of centromeric regions. Within these regions, we identified novel 13-mer higher-order repeat patterns on chromosome 17 which exhibited a monophyletic origin and emerged approximately 230 thousand years ago. Overall, this work establishes an essential genomic resource for the Han Chinese population and advances the development of a T2T pan-Chinese reference genome, which will significantly enable future investigations both into population-specific structural variants and the evolutionary dynamics of centromeres.
- 26 November 2025
- Published by Oxford University Press (OUP) in Genomics, Proteomics & Bioinformatics
- Vol. 23 (6)
Open AccessA Telomere-to-telomere Diploid Reference Genome and Centromere Structure of the Chinese Quartet
Recent advances in sequencing technologies have enabled the complete assembly of human genomes from telomere to telomere (T2T), resolving previously inaccessible regions such as centromeres and segmental duplications. Here, we present an updated, higher-quality, haplotype-phased T2T assembly of the Chinese Quartet (T2T-CQ), a family cohort comprising monozygotic twins and their parents, generated using high-coverage Oxford Nanopore Technologies (ONT) ultralong and PacBio high-fidelity (HiFi) sequencing. The T2T-CQ assembly serves as a crucial reference genome for integrating publicly available multi-omics data and advances the utility of the Quartet reference materials. The T2T-CQ assembly scores highly on multiple metrics of continuity and completeness, with Genome Continuity Inspector (GCI) scores of 77.76 (maternal) and 76.41 (paternal), 21-mer quality values (QVs) > 66, and Clipping Reveals Assembly Quality (CRAQ) scores > 99.6 for both haplotypes, enabling complete annotation of centromeric regions. Within these regions, we identified novel 13-mer higher-order repeat patterns on chromosome 17 which exhibited a monophyletic origin and emerged approximately 230 thousand years ago. Overall, this work establishes an essential genomic resource for the Han Chinese population and advances the development of a T2T pan-Chinese reference genome, which will significantly enable future investigations both into population-specific structural variants and the evolutionary dynamics of centromeres.