Yunhang Jing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yunhang Jing has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Xinyue Xu
3 shared publicationsKe Chang
2 shared publicationsRui Guo
2 shared publicationsDanni Wang
1 shared publicationHongman Chen
Department of Radiology, The Second Hospital and Clinical Medical School, Lanzhou University
1 shared publication- Jiahui Liang
Department of Radiology, The Second Hospital and Clinical Medical School, Lanzhou University
1 shared publication
Latest Publications
- 20 October 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
Can Spectral CT Serve as a Surrogate for Perfusion CT to Evaluate Lymphovascular and Perineural Invasion in Gastric Cancer? A Prospective Study Using a One-Stop CT Protocol
Objective: To evaluate the clinical utility of a “One-stop” spectral CT combined with perfusion CT scan for preoperative assessment of lymphovascular invasion (LVI) and perineural invasion (PNI) in gastric cancer (GC) and to investigate whether spectral CT parameters can serve as reliable surrogates for perfusion CT biomarkers in risk stratification. Methods: In this prospective study, 87 patients with histologically confirmed gastric adenocarcinoma underwent preoperative contrast-enhanced “One-stop” spectral CT combined with perfusion CT scan at our institution. Patients were stratified into LVI/PNI-positive (n=65) and LVI/PNI-negative (n=22) groups based on postoperative pathology. Spectral parameters—including iodine concentration (IC), effective atomic number (Zeff), and water concentration (WC)—were measured in arterial (AP) and venous (VP) phases. Perfusion parameters included blood volume (BV), blood flow (BF), mean transit time (MTT), permeability-surface area product (PS), and time to peak (Tmax). Intergroup comparisons, diagnostic performance evaluation, and correlation analyses between spectral and perfusion parameters were performed. Results: Significant differences were observed between LVI/PNI-positive and -negative groups for Zeff (in both AP and VP), IC (in VP), BV, and MTT (all P 1 score of 0.892. Notably, VP-IC demonstrated a strong positive correlation with BV (Spearman ρ =0.751, P <0.001), underscoring the potential of spectral CT to reflect tumor perfusion noninvasively. Conclusion: Spectral CT parameters, particularly VP-IC, show a strong correlation with the perfusion biomarker BV and offer comparable diagnostic accuracy for detecting LVI/PNI in GC. This supports the role of spectral CT as a viable surrogate for perfusion CT. The integrated “One-stop” protocol, enabling simultaneous acquisition of both data sets in a single scan, provides a streamlined and clinically practical approach to preoperative risk stratification.
- 20 October 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
Can Spectral CT Serve as a Surrogate for Perfusion CT to Evaluate Lymphovascular and Perineural Invasion in Gastric Cancer? A Prospective Study Using a One-Stop CT Protocol
Objective: To evaluate the clinical utility of a “One-stop” spectral CT combined with perfusion CT scan for preoperative assessment of lymphovascular invasion (LVI) and perineural invasion (PNI) in gastric cancer (GC) and to investigate whether spectral CT parameters can serve as reliable surrogates for perfusion CT biomarkers in risk stratification. Methods: In this prospective study, 87 patients with histologically confirmed gastric adenocarcinoma underwent preoperative contrast-enhanced “One-stop” spectral CT combined with perfusion CT scan at our institution. Patients were stratified into LVI/PNI-positive (n=65) and LVI/PNI-negative (n=22) groups based on postoperative pathology. Spectral parameters—including iodine concentration (IC), effective atomic number (Zeff), and water concentration (WC)—were measured in arterial (AP) and venous (VP) phases. Perfusion parameters included blood volume (BV), blood flow (BF), mean transit time (MTT), permeability-surface area product (PS), and time to peak (Tmax). Intergroup comparisons, diagnostic performance evaluation, and correlation analyses between spectral and perfusion parameters were performed. Results: Significant differences were observed between LVI/PNI-positive and -negative groups for Zeff (in both AP and VP), IC (in VP), BV, and MTT (all P 1 score of 0.892. Notably, VP-IC demonstrated a strong positive correlation with BV (Spearman ρ =0.751, P <0.001), underscoring the potential of spectral CT to reflect tumor perfusion noninvasively. Conclusion: Spectral CT parameters, particularly VP-IC, show a strong correlation with the perfusion biomarker BV and offer comparable diagnostic accuracy for detecting LVI/PNI in GC. This supports the role of spectral CT as a viable surrogate for perfusion CT. The integrated “One-stop” protocol, enabling simultaneous acquisition of both data sets in a single scan, provides a streamlined and clinically practical approach to preoperative risk stratification.
- Open Access
- 1 October 2026
- Published by AME Publishing Company in Translational Cancer Research
- Vol. 15 (10) , 740
Non-contrast dual-layer spectral detector CT combined with laboratory indicators for differentiating hepatic hemangiomas from malignant liver tumours: development and internal validation of a diagnostic prediction model
Background: Hepatic hemangiomas, hepatocellular carcinoma (HCC), and metastatic liver cancer (MLC) may all appear hypoattenuating or isoattenuating on conventional non-contrast computed tomography (CT), whereas their characteristic differentiating features are largely demonstrated on contrast-enhanced imaging. Lesion characterisation therefore remains challenging when iodinated contrast administration is limited, such as in patients with renal dysfunction or a history of hypersensitivity to iodinated contrast media, or when liver lesions are incidentally detected on non-contrast CT. This study aimed to develop and internally validate a diagnostic prediction model combining non-contrast dual-layer spectral detector CT (SDCT) quantitative parameters with clinical and laboratory indicators to differentiate hepatic hemangiomas (HH) from malignant liver tumours. Methods: This retrospective study included patients who underwent abdominal SDCT between January and June 2025. Eligibility required pretreatment non-contrast and contrast-enhanced spectral CT and a maximum lesion diameter >1 cm; liver lesions other than HH, HCC, or MLC were excluded. Diagnosis was based on surgical or biopsy pathology when available and otherwise on multimodal imaging findings combined with prior imaging. Eighteen predictors were evaluated: six clinical/laboratory variables and 12 non-contrast SDCT parameters. Variables with PResults: A total of 119 patients were included: 63 with HH and 56 with malignant liver tumours, including 25 with HCC and 31 with MLC. Lymphocyte-to-monocyte ratio, the CT attenuation range on 70-keV virtual monoenergetic images, and electron density were retained in the combined model. The AUCs of the clinical, imaging, and combined models were 0.752 [95% confidence interval (CI): 0.665–0.840], 0.797 (95% CI: 0.715–0.879), and 0.866 (95% CI: 0.800–0.932), respectively. The combined model outperformed the clinical and imaging models on DeLong testing (P=0.002 and P=0.007, respectively). Its sensitivity, specificity, and accuracy were 75.0%, 85.7%, and 80.7%, respectively. Brier scores were 0.199, 0.178, and 0.146 for the clinical, imaging, and combined models, respectively. DCA suggested potential clinical net benefit, and the bootstrap optimism-corrected AUC of the combined model was 0.833. Conclusions: A diagnostic prediction model combining non-contrast SDCT quantitative parameters with clinical and laboratory indicators showed better discrimination than either the clinical or imaging model alone and acceptable calibration for the preliminary differentiation of HHs from malignant liver tumours. When contrast-enhanced imaging is limited, the model may support adjunctive risk stratification. Because only internal validation was performed, external validation in independent populations is required.
- 1 October 2026
- Published by AME Publishing Company in Translational Cancer Research
- Vol. 15 (10) , 740
Open AccessNon-contrast dual-layer spectral detector CT combined with laboratory indicators for differentiating hepatic hemangiomas from malignant liver tumours: development and internal validation of a diagnostic prediction model
Background: Hepatic hemangiomas, hepatocellular carcinoma (HCC), and metastatic liver cancer (MLC) may all appear hypoattenuating or isoattenuating on conventional non-contrast computed tomography (CT), whereas their characteristic differentiating features are largely demonstrated on contrast-enhanced imaging. Lesion characterisation therefore remains challenging when iodinated contrast administration is limited, such as in patients with renal dysfunction or a history of hypersensitivity to iodinated contrast media, or when liver lesions are incidentally detected on non-contrast CT. This study aimed to develop and internally validate a diagnostic prediction model combining non-contrast dual-layer spectral detector CT (SDCT) quantitative parameters with clinical and laboratory indicators to differentiate hepatic hemangiomas (HH) from malignant liver tumours. Methods: This retrospective study included patients who underwent abdominal SDCT between January and June 2025. Eligibility required pretreatment non-contrast and contrast-enhanced spectral CT and a maximum lesion diameter >1 cm; liver lesions other than HH, HCC, or MLC were excluded. Diagnosis was based on surgical or biopsy pathology when available and otherwise on multimodal imaging findings combined with prior imaging. Eighteen predictors were evaluated: six clinical/laboratory variables and 12 non-contrast SDCT parameters. Variables with PResults: A total of 119 patients were included: 63 with HH and 56 with malignant liver tumours, including 25 with HCC and 31 with MLC. Lymphocyte-to-monocyte ratio, the CT attenuation range on 70-keV virtual monoenergetic images, and electron density were retained in the combined model. The AUCs of the clinical, imaging, and combined models were 0.752 [95% confidence interval (CI): 0.665–0.840], 0.797 (95% CI: 0.715–0.879), and 0.866 (95% CI: 0.800–0.932), respectively. The combined model outperformed the clinical and imaging models on DeLong testing (P=0.002 and P=0.007, respectively). Its sensitivity, specificity, and accuracy were 75.0%, 85.7%, and 80.7%, respectively. Brier scores were 0.199, 0.178, and 0.146 for the clinical, imaging, and combined models, respectively. DCA suggested potential clinical net benefit, and the bootstrap optimism-corrected AUC of the combined model was 0.833. Conclusions: A diagnostic prediction model combining non-contrast SDCT quantitative parameters with clinical and laboratory indicators showed better discrimination than either the clinical or imaging model alone and acceptable calibration for the preliminary differentiation of HHs from malignant liver tumours. When contrast-enhanced imaging is limited, the model may support adjunctive risk stratification. Because only internal validation was performed, external validation in independent populations is required.
- 27 March 2026
- Published by Springer Nature in Abdominal Radiology
- Vol. 51 (10) , 4802-4812
Dual-layer detector spectral CT–derived extracellular volume fraction combined with clinical parameters for predicting lymphovascular and perineural invasion in gastric cancer
This study aimed to evaluate the feasibility and diagnostic performance of extracellular volume fraction (ECV), derived from iodine concentration (IC) values obtained through dual-layer detector spectral CT, in combination with clinical parameters, for preoperative prediction of lymphovascular invasion and/or perineural invasion (LVI/PNI) in gastric cancer. This retrospective study included clinical and pathologic data of 124 patients diagnosed with GC at our hospital between September 2023 and February 2025. The patients were stratified into LVI/PNI-positive (n = 85) and LVI/PNI-negative (n = 39) groups based on their postoperative histopathologic findings. All patients underwent contrast-enhanced dual-layer detector spectral CT. Preoperative hematocrit levels were obtained, and IC values within the tumor were measured during the delayed phase. Concurrently, IC in the abdominal aorta at the same anatomical level was measured to calculate the ECV using the formula: ECV = (1 - hematocrit) × (IC_tumor / IC_blood). Clinical variables and spectral CT parameters were analyzed using univariate analysis, LASSO selection, and multivariable logistic regression to identify independent predictors of the composite LVI/PNI endpoint. The diagnostic performance of individual parameters and the combined model for preoperatively predicting vascular and neural invasion was assessed using receiver operating characteristic (ROC) curve analysis. ECV, CT-N stage, and Borrmann classification were identified as independent predictors of the composite LVI/PNI endpoint in patients with GC (all P < 0.05). Among the candidate models, the combined model incorporating ECV, CT-N stage, and Borrmann classification achieved the best predictive performance, with AUCs of 0.920 in the training cohort and 0.917 in the validation cohort. DeLong analysis showed that the combined model significantly outperformed the CT-N stage model and the Borrmann classification model in both cohorts. However, its improvement over the ECV-only model was not statistically significant. Delayed-phase dual-layer detector spectral CT-derived ECV is a promising noninvasive biomarker for identifying the composite LVI/PNI endpoint in gastric cancer. A combined model integrating ECV, CT-N stage, and Borrmann classification provides the best overall diagnostic performance, although its incremental benefit over ECV alone appears limited.
- 27 March 2026
- Published by Springer Nature in Abdominal Radiology
- Vol. 51 (10) , 4802-4812
Dual-layer detector spectral CT–derived extracellular volume fraction combined with clinical parameters for predicting lymphovascular and perineural invasion in gastric cancer
This study aimed to evaluate the feasibility and diagnostic performance of extracellular volume fraction (ECV), derived from iodine concentration (IC) values obtained through dual-layer detector spectral CT, in combination with clinical parameters, for preoperative prediction of lymphovascular invasion and/or perineural invasion (LVI/PNI) in gastric cancer. This retrospective study included clinical and pathologic data of 124 patients diagnosed with GC at our hospital between September 2023 and February 2025. The patients were stratified into LVI/PNI-positive (n = 85) and LVI/PNI-negative (n = 39) groups based on their postoperative histopathologic findings. All patients underwent contrast-enhanced dual-layer detector spectral CT. Preoperative hematocrit levels were obtained, and IC values within the tumor were measured during the delayed phase. Concurrently, IC in the abdominal aorta at the same anatomical level was measured to calculate the ECV using the formula: ECV = (1 - hematocrit) × (IC_tumor / IC_blood). Clinical variables and spectral CT parameters were analyzed using univariate analysis, LASSO selection, and multivariable logistic regression to identify independent predictors of the composite LVI/PNI endpoint. The diagnostic performance of individual parameters and the combined model for preoperatively predicting vascular and neural invasion was assessed using receiver operating characteristic (ROC) curve analysis. ECV, CT-N stage, and Borrmann classification were identified as independent predictors of the composite LVI/PNI endpoint in patients with GC (all P < 0.05). Among the candidate models, the combined model incorporating ECV, CT-N stage, and Borrmann classification achieved the best predictive performance, with AUCs of 0.920 in the training cohort and 0.917 in the validation cohort. DeLong analysis showed that the combined model significantly outperformed the CT-N stage model and the Borrmann classification model in both cohorts. However, its improvement over the ECV-only model was not statistically significant. Delayed-phase dual-layer detector spectral CT-derived ECV is a promising noninvasive biomarker for identifying the composite LVI/PNI endpoint in gastric cancer. A combined model integrating ECV, CT-N stage, and Borrmann classification provides the best overall diagnostic performance, although its incremental benefit over ECV alone appears limited.
- 19 March 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 199, 112800
Letter to the Editor: an interpretable radiomics model based on dual-energy spectral CT iodine maps for predicting microsatellite instability in colorectal cancer—methodological considerations and clinical implications
- 19 March 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 199, 112800
Letter to the Editor: an interpretable radiomics model based on dual-energy spectral CT iodine maps for predicting microsatellite instability in colorectal cancer—methodological considerations and clinical implications