Chengguang Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengguang Fan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Jinsong Yang
Central South University
3 shared publicationsXiaozhen Zhang
National University of Defense Technology
2 shared publicationsZhao Yong
College of Aerospace Science and Engineering, National University of Defense Technology, Changsha, PR China
2 shared publications- Xiaozhen Zhang
National University of Defense Technology
1 shared publication Yong Zhao
National University of Defense Technology
1 shared publication
Latest Publications
- 10 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455104
Lamb wave damage localization under variable temperature using dual array MUSIC beamforming with joint amplitude and phase compensation
Temperature variations can significantly alter Lamb-wave amplitude, phase, and propagation velocity, thereby degrading damage localization and imaging performance in structural health monitoring. This study proposes a temperature-robust dual-array MUSIC–beamforming method for Lamb-wave damage localization. A temperature-dependent near-field propagation model is established to represent the combined amplitude and phase distortions using an element-wise complex error matrix. A cost-function optimization scheme is then developed to jointly estimate the damage location and temperature-induced compensation parameters through alternating updates, without requiring a complete reference signal at every temperature. The compensated MUSIC spectrum is further fused with a delay-and-sum beamforming map to combine high angular resolution with physically meaningful signal-energy distribution. Experiments were conducted on three Al6061 plates containing artificial defects over a temperature range of −40 °C–80 °C. At five calibrated temperatures, the relative localization errors ranged from 1.76%–8.12%. At six intermediate temperatures without direct calibration, the maximum error was 9.52%, with a mean error of 6.99%. The method also maintained gradual performance degradation under additive white Gaussian noise, with the maximum error reaching 14.1% at 0 dB SNR. These results demonstrate that the proposed method provides accurate and robust Lamb-wave damage localization and improved image contrast under variable-temperature conditions.
- 10 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455104
Lamb wave damage localization under variable temperature using dual array MUSIC beamforming with joint amplitude and phase compensation
Temperature variations can significantly alter Lamb-wave amplitude, phase, and propagation velocity, thereby degrading damage localization and imaging performance in structural health monitoring. This study proposes a temperature-robust dual-array MUSIC–beamforming method for Lamb-wave damage localization. A temperature-dependent near-field propagation model is established to represent the combined amplitude and phase distortions using an element-wise complex error matrix. A cost-function optimization scheme is then developed to jointly estimate the damage location and temperature-induced compensation parameters through alternating updates, without requiring a complete reference signal at every temperature. The compensated MUSIC spectrum is further fused with a delay-and-sum beamforming map to combine high angular resolution with physically meaningful signal-energy distribution. Experiments were conducted on three Al6061 plates containing artificial defects over a temperature range of −40 °C–80 °C. At five calibrated temperatures, the relative localization errors ranged from 1.76%–8.12%. At six intermediate temperatures without direct calibration, the maximum error was 9.52%, with a mean error of 6.99%. The method also maintained gradual performance degradation under additive white Gaussian noise, with the maximum error reaching 14.1% at 0 dB SNR. These results demonstrate that the proposed method provides accurate and robust Lamb-wave damage localization and improved image contrast under variable-temperature conditions.
- Top Cited Papers
- 25 June 2026
- Published by SAGE Publications in Structural Health Monitoring
Adaptive compensated MUSIC beamforming for Lamb wave damage localization under varying temperature
Structural health monitoring based on Lamb waves is significantly challenged by environmental temperature variations, which introduce complex signal distortions that can obscure damage-related features. A Lamb wave damage localization methodology based on a compensated multiple signal classification (MUSIC)-beamforming framework using dual sensor arrays is presented under variable temperature conditions. The methodology is underpinned by a comprehensive array signal propagation model that has been developed to characterize temperature-induced effects on wave propagation, with explicit consideration given to both amplitude and phase variations. An enhanced near-field MUSIC formulation is developed in which temperature-induced amplitude and phase distortions are characterized by a calibrated error matrix; phase compensation restores the angular estimate while amplitude compensation preserves the beamforming gain and imaging quality. The methodology is further augmented through the integration of beamforming techniques, which serve to enhance spatial filtering capabilities and improve imaging resolution under varying temperature conditions. Extensive experimental validation has been conducted on aluminum plates with artificial damages, where temperature conditions were systematically varied from −40 to 80°C. The experimental results have demonstrated that consistent localization accuracy can be achieved with relative errors maintained below 9% across all temperature conditions.
- 25 June 2026
- Published by SAGE Publications in Structural Health Monitoring
Top Cited PapersAdaptive compensated MUSIC beamforming for Lamb wave damage localization under varying temperature
Structural health monitoring based on Lamb waves is significantly challenged by environmental temperature variations, which introduce complex signal distortions that can obscure damage-related features. A Lamb wave damage localization methodology based on a compensated multiple signal classification (MUSIC)-beamforming framework using dual sensor arrays is presented under variable temperature conditions. The methodology is underpinned by a comprehensive array signal propagation model that has been developed to characterize temperature-induced effects on wave propagation, with explicit consideration given to both amplitude and phase variations. An enhanced near-field MUSIC formulation is developed in which temperature-induced amplitude and phase distortions are characterized by a calibrated error matrix; phase compensation restores the angular estimate while amplitude compensation preserves the beamforming gain and imaging quality. The methodology is further augmented through the integration of beamforming techniques, which serve to enhance spatial filtering capabilities and improve imaging resolution under varying temperature conditions. Extensive experimental validation has been conducted on aluminum plates with artificial damages, where temperature conditions were systematically varied from −40 to 80°C. The experimental results have demonstrated that consistent localization accuracy can be achieved with relative errors maintained below 9% across all temperature conditions.
- Top Cited Papers
- 27 March 2026
- Published by Elsevier in Measurement
- Vol. 274
Quantitative monitoring method for hydrochloric acid corrosion based on cumulative damage indices using ultrasonic guided waves
- 27 March 2026
- Published by Elsevier in Measurement
- Vol. 274
Top Cited PapersQuantitative monitoring method for hydrochloric acid corrosion based on cumulative damage indices using ultrasonic guided waves