Esteban E. Barrera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Esteban E. Barrera has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Zacarias
Sección de Estudios de Posgrado e Investigación, ESIME Azcapotzalco, Instituto Politécnico Nacional, Av. de las Granjas no. 682, México City 02250, Mexico
2 shared publications - René Osvaldo Vargas-Aguilar
Departamento de Termofluidos, SEPI-ESIME Unidad Azcapotzalco, Instituto Politécnico Nacional, Ciudad de México 02250, Mexico
2 shared publications - Rubén Mil-Martínez
Departamento de Ingeniería Industrial, Escuela Militar de Ingeniería, Universidad del Ejército y Fuerza Aérea, Mexico City, Mexico, Mexico
2 shared publications - Alberto Beltrán
Instituto de Investigaciones en Materiales, Unidad Morelia, Universidad Nacional Autónoma de México, Antigua Carretera a Pátzcuaro 8701, Ex Hacienda de San José de la Huerta, Morelia 58190, Michoacán, Mexico
1 shared publication - Alberto Iván García Flores
Academia de Térmicas/Termofluidos, Escuela Superior de Ingeniería Mecánica y Eléctrica Azcapotzalco, Instituto Politécnico Nacional, Mexico City 02550, Mexico
1 shared publication - Alejandra M. Mil-Martínez
Escuela Militar de Ingeniería, Universidad del Ejército y la Fuerza Aérea, Av. Industria Militar No. 261, Col. Lomas de San Isidro, Naucalpan de Juárez 53960, Mexico
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by Elsevier in Next Energy
- Vol. 13
Thermophysical properties of the water/DEA cocamide/fullerene C60 nanofluid and its evaluation in a double-pipe heat exchanger
- 23 October 2026
- Published by Elsevier in Next Energy
- Vol. 13
Open AccessThermophysical properties of the water/DEA cocamide/fullerene C60 nanofluid and its evaluation in a double-pipe heat exchanger
- Open Access
- 28 March 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (7) , 3301
Performance Assessment of a Low-Global-Warming-Potential Solar-Powered Generator–Chiller
This article presents a performance assessment of an electrical power and cooling system powered by a parabolic dish collector and using refrigerants with low global warming potential. The study was conducted using energy and mass balances for each component and system. The simulation includes various parameters, such as solar radiation, the focal temperature of the solar collector, the ambient temperature, the power cycle pressure ratio, and the chiller’s evaporation temperature. The results show that the efficiency of the organic Rankine cycle with the refrigerant R1233zd(E) is similar to that of the refrigerants R123 and R245fa and is up to 11 and 50 times lower than with R290 and R744, respectively. The solar absorption chiller using the refrigerant R717 can achieve cooling with a supply temperature up to 5 °C lower than that of R718. The dynamic simulation results show that the energy efficiency of the proposed solar-powered generator–chiller is 14% higher than that of a standard solar-powered absorption chiller. Furthermore, the same solar-powered generator–chiller reduces the primary energy required by a conventional system by 60% (PESr = 0.60). The presented results may be useful for the design of sustainable generator–chillers for rural areas or for autonomous housing in tropical climates.
- 28 March 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (7) , 3301
Open AccessPerformance Assessment of a Low-Global-Warming-Potential Solar-Powered Generator–Chiller
This article presents a performance assessment of an electrical power and cooling system powered by a parabolic dish collector and using refrigerants with low global warming potential. The study was conducted using energy and mass balances for each component and system. The simulation includes various parameters, such as solar radiation, the focal temperature of the solar collector, the ambient temperature, the power cycle pressure ratio, and the chiller’s evaporation temperature. The results show that the efficiency of the organic Rankine cycle with the refrigerant R1233zd(E) is similar to that of the refrigerants R123 and R245fa and is up to 11 and 50 times lower than with R290 and R744, respectively. The solar absorption chiller using the refrigerant R717 can achieve cooling with a supply temperature up to 5 °C lower than that of R718. The dynamic simulation results show that the energy efficiency of the proposed solar-powered generator–chiller is 14% higher than that of a standard solar-powered absorption chiller. Furthermore, the same solar-powered generator–chiller reduces the primary energy required by a conventional system by 60% (PESr = 0.60). The presented results may be useful for the design of sustainable generator–chillers for rural areas or for autonomous housing in tropical climates.