Ruimeng Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruimeng Xia has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Chen Wang
Beijing Urban Construction Design and Development Group Co., Ltd., Beijing 100037, China
1 shared publication - Jianning Wang
China National Machinery Industry Co., Ltd., Beijing, China
1 shared publication - Jing Yang
Jiangxi Provincial Key Laboratory of Traffic Infrastructure Safety, East China Jiaotong University, Nanchang 330013, China
1 shared publication - Zigang Xu
State Key Laboratory of Performance Monitoring and Protecting of Rail Transit Infrastructure, East China Jiaotong University, Nanchang 330013, China
1 shared publication
Latest Publications
- Open Access
Seismic Response and Mitigation Measures of Large Unequal-Span Subway Station Structures in Liquefiable Sites
The deformation of surrounding soil primarily governs the behavior of underground structures. Consequently, variations in their external geometry significantly affect their overall seismic response. Moreover, large soil deformations and structural uplift caused by liquefaction severely threaten their seismic safety. While most previous studies have focused on conventional rectangular subway stations, the seismic performance of novel varying-span structures remains largely unexplored. In this study, nonlinear dynamic time-history analyses are conducted to investigate the soil–structure interaction (SSI) of large unequal-span subway stations in liquefiable sites. Furthermore, the seismic responses of both the structure and the surrounding soil are systematically evaluated under various burial depths of the liquefiable layer. Finally, a U-shaped foundation reinforcement method is proposed to mitigate structural uplift. The results show that unequal-span structures suppress liquefaction in lateral soil, whereas significant liquefaction occurs beneath the base slab and cantilevered middle slabs. The burial depth of the liquefiable layer has a negligible effect on the liquefaction state directly under the center span. Regarding structural response, global uplift follows a spatial pattern that peaks at the center span and gradually attenuates laterally. Although the proposed U-shaped reinforcement effectively reduces both total and differential uplift, it does not fundamentally change the underlying liquefaction mechanism. Specifically, reinforcing the soil under cantilevered sections minimizes differential uplift while enhancing the overall economic efficiency of the seismic design. These findings provide a scientific basis for optimizing the seismic resilience of complex underground structures, contributing to the development of resource-efficient and disaster-resilient urban underground infrastructure in liquefaction-prone regions.
Open AccessSeismic Response and Mitigation Measures of Large Unequal-Span Subway Station Structures in Liquefiable Sites
The deformation of surrounding soil primarily governs the behavior of underground structures. Consequently, variations in their external geometry significantly affect their overall seismic response. Moreover, large soil deformations and structural uplift caused by liquefaction severely threaten their seismic safety. While most previous studies have focused on conventional rectangular subway stations, the seismic performance of novel varying-span structures remains largely unexplored. In this study, nonlinear dynamic time-history analyses are conducted to investigate the soil–structure interaction (SSI) of large unequal-span subway stations in liquefiable sites. Furthermore, the seismic responses of both the structure and the surrounding soil are systematically evaluated under various burial depths of the liquefiable layer. Finally, a U-shaped foundation reinforcement method is proposed to mitigate structural uplift. The results show that unequal-span structures suppress liquefaction in lateral soil, whereas significant liquefaction occurs beneath the base slab and cantilevered middle slabs. The burial depth of the liquefiable layer has a negligible effect on the liquefaction state directly under the center span. Regarding structural response, global uplift follows a spatial pattern that peaks at the center span and gradually attenuates laterally. Although the proposed U-shaped reinforcement effectively reduces both total and differential uplift, it does not fundamentally change the underlying liquefaction mechanism. Specifically, reinforcing the soil under cantilevered sections minimizes differential uplift while enhancing the overall economic efficiency of the seismic design. These findings provide a scientific basis for optimizing the seismic resilience of complex underground structures, contributing to the development of resource-efficient and disaster-resilient urban underground infrastructure in liquefaction-prone regions.