He Pang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
He Pang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jinhui Zeng
Hunan University of Technology
1 shared publication - Qunfang Wu
Nanjing University of Aeronautics and Astronautics
1 shared publication - Zheng Lan
College of Electrical and Information Engineering, Hunan University of Technology, Zhuzhou 412007, China
1 shared publication - Zhifeng Sun
Hunan University of Technology, Zhuzhou, China
1 shared publication
Latest Publications
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
An Improved Current Sharing Control Strategy of IPOP-DAB Converter Based on Continuous Perturbation Estimation Method (CPEM)
Input-parallel output-parallel (IPOP) dual active bridge (DAB) converter has emerged as a promising candidate for achieving isolated DC–DC power conversion with large current capability. However, parameter mismatch, such as inductance among individual modules, will induce current imbalance issues. Accurate estimation of parameter mismatch enables adaptive adjustment of phase-shift angles for each module to achieve current sharing. Constrained by the coupled characteristics of IPOP systems, conventional estimation methods face limitations in multiphase system scalability and practicality. To address this challenge, this article proposes a continuous perturbation estimation method (CPEM). The core principle is to apply fixed phase-shift angle perturbations to each module, followed by monitoring the variations in voltage closed-loop output values after each perturbation cycle. Then, the parameter mismatch information of each module can be indirectly estimated. Considering that operating conditions may change during the perturbation process, input voltage and load variations are further incorporated into the estimation model. Notably, the proposed method does not need to consider the coupling characteristics of IPOP systems and has the advantages of simple operation and practicality. Finally, a current-sharing control scheme is developed and experimentally validated through a four-phase prototype platform. Experimental results demonstrate an estimation error of 1.5% and current-sharing error below 3% across the full load range, confirming the theoretical analysis.
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
An Improved Current Sharing Control Strategy of IPOP-DAB Converter Based on Continuous Perturbation Estimation Method (CPEM)
Input-parallel output-parallel (IPOP) dual active bridge (DAB) converter has emerged as a promising candidate for achieving isolated DC–DC power conversion with large current capability. However, parameter mismatch, such as inductance among individual modules, will induce current imbalance issues. Accurate estimation of parameter mismatch enables adaptive adjustment of phase-shift angles for each module to achieve current sharing. Constrained by the coupled characteristics of IPOP systems, conventional estimation methods face limitations in multiphase system scalability and practicality. To address this challenge, this article proposes a continuous perturbation estimation method (CPEM). The core principle is to apply fixed phase-shift angle perturbations to each module, followed by monitoring the variations in voltage closed-loop output values after each perturbation cycle. Then, the parameter mismatch information of each module can be indirectly estimated. Considering that operating conditions may change during the perturbation process, input voltage and load variations are further incorporated into the estimation model. Notably, the proposed method does not need to consider the coupling characteristics of IPOP systems and has the advantages of simple operation and practicality. Finally, a current-sharing control scheme is developed and experimentally validated through a four-phase prototype platform. Experimental results demonstrate an estimation error of 1.5% and current-sharing error below 3% across the full load range, confirming the theoretical analysis.