Wenjun Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenjun Yao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Zhihong Tian
Guangzhou University
3 shared publications - Binxing Fang
Guangzhou University
2 shared publications - Hui Lu
Guangzhou University
2 shared publications - Yanbin Sun
Guangzhou University
2 shared publications - Guodong Wu
Cyberspace Institute of Advanced Technology, Guangzhou University, Guangzhou, China
1 shared publication Rui Wang
Cyberspace Institute of Advanced Technology, Guangzhou University, Guangdong Key Laboratory of Industrial Control System Security, and Huangpu Research School of Guangzhou University, Guangzhou, China
1 shared publication
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Services Computing
- Vol. 19 (5) , 3402-3415
Calling the Shots: Constraint-Aware Honeypoint Orchestration for Cloud-Native Anomaly Response
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Services Computing
- Vol. 19 (5) , 3402-3415
Calling the Shots: Constraint-Aware Honeypoint Orchestration for Cloud-Native Anomaly Response
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. PP (15361233) , 1-14
H4PLC: Designing PLC Honeypoints Based on Invariants for Industrial Control System Security
Unlike traditional Programmable Logic Controller (PLC) honeypots, a PLC honeypoint is a lightweight, easily deployable decoy that emulates realistic Industrial Control System (ICS) services to deceive attackers and uncover their malicious intent. PLC honeypoints are an effective mechanism for enhancing ICS defense against cyber attackers. However, existing PLC honeypoints lack realism in their services, failing to sufficiently engage attackers during reconnaissance or interaction phases. To address this gap, we introduce H4PLC, a novel PLC honeypoint that employs an invariant-based approach to incorporate realistic ICS physical process properties. H4PLC overcomes challenges in characterizing and integrating these properties into PLC services by leveraging ICS log data to construct Physical Process Trees and control rule transitions, enabling dynamic and authentic responses to attacker reconnaissance and malicious code injections. To the best of our knowledge, H4PLC is the first PLC honeypoint to generate contextually variable, appropriate, and responsive ICS messages tailored to Advanced Persistent Threat (APT) attackers. Experimental evaluations demonstrate that H4PLC provides diverse realistic PLC services and effectively reports anomalies under malicious code injections.
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. PP (15361233) , 1-14
H4PLC: Designing PLC Honeypoints Based on Invariants for Industrial Control System Security
Unlike traditional Programmable Logic Controller (PLC) honeypots, a PLC honeypoint is a lightweight, easily deployable decoy that emulates realistic Industrial Control System (ICS) services to deceive attackers and uncover their malicious intent. PLC honeypoints are an effective mechanism for enhancing ICS defense against cyber attackers. However, existing PLC honeypoints lack realism in their services, failing to sufficiently engage attackers during reconnaissance or interaction phases. To address this gap, we introduce H4PLC, a novel PLC honeypoint that employs an invariant-based approach to incorporate realistic ICS physical process properties. H4PLC overcomes challenges in characterizing and integrating these properties into PLC services by leveraging ICS log data to construct Physical Process Trees and control rule transitions, enabling dynamic and authentic responses to attacker reconnaissance and malicious code injections. To the best of our knowledge, H4PLC is the first PLC honeypoint to generate contextually variable, appropriate, and responsive ICS messages tailored to Advanced Persistent Threat (APT) attackers. Experimental evaluations demonstrate that H4PLC provides diverse realistic PLC services and effectively reports anomalies under malicious code injections.
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dependable and Secure Computing
- Vol. 23 (3) , 6568-6583
Pipe4Stux: Attacking PLC by Using Key Tag and Attack Semantic
Semantic attacks against programmable logic controllers (PLCs) can manipulate industrial control systems (ICS) and cause severe physical disruptions. Yet, existing researches remain target-agnostic: they fail to determine which PLC tags or physical process are most critical when exploited. To address this gap, we introduce Pipe4Stux, a semantic attack framework that generates effective PLC attacks by leveraging key tags and attack semantics. Pipe4Stux first constructs a lexical analyzer and a data dependency subgraph from PLC control logic to capture the relationships among variables and operations. It then identifies key tags, derives semantic features of attacks, and formulates process-aware attack tactic. Experimental results on real ICS scenarios demonstrate that Pipe4Stux enables destructive and reproducible semantic attacks, revealing the potential impact of compromising key tags during specific physical states. In addition, Pipe4Stux provides the first systematic and objective methodology for semantic attack synthesis, offering practical guidance for defense. The framework can also support continuous monitoring by designating key tags as alarm variables within supervisory control and data acquisition (SCADA) systems such as WINCC.
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dependable and Secure Computing
- Vol. 23 (3) , 6568-6583
Pipe4Stux: Attacking PLC by Using Key Tag and Attack Semantic
Semantic attacks against programmable logic controllers (PLCs) can manipulate industrial control systems (ICS) and cause severe physical disruptions. Yet, existing researches remain target-agnostic: they fail to determine which PLC tags or physical process are most critical when exploited. To address this gap, we introduce Pipe4Stux, a semantic attack framework that generates effective PLC attacks by leveraging key tags and attack semantics. Pipe4Stux first constructs a lexical analyzer and a data dependency subgraph from PLC control logic to capture the relationships among variables and operations. It then identifies key tags, derives semantic features of attacks, and formulates process-aware attack tactic. Experimental results on real ICS scenarios demonstrate that Pipe4Stux enables destructive and reproducible semantic attacks, revealing the potential impact of compromising key tags during specific physical states. In addition, Pipe4Stux provides the first systematic and objective methodology for semantic attack synthesis, offering practical guidance for defense. The framework can also support continuous monitoring by designating key tags as alarm variables within supervisory control and data acquisition (SCADA) systems such as WINCC.