Murat Harman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Murat Harman has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Aksu
Department of Anesthesiology and Reanimation, Faculty of Medicine, Fırat University, 23119 Elazığ, Türkiye
1 shared publication - Aysun Yildiz Altun
Department of Anesthesiology and Reanimation, Faculty of Medicine, Firat University, TR23119 Elazig, Turkey
1 shared publication - Esef Bolat
Department of Anaesthesiology and Reanimation, Faculty of Medicine, Firat University, Elazig, Turkey
1 shared publication - Fatma Celik
Department of Anaesthesiology and Reanimation, Faculty of Medicine, Firat University, Elazig, Turkey
1 shared publication - Gülsüm Altuntaş
Department of Anesthesiology and Reanimation, Faculty of Medicine, Fırat University, Elazığ, Turkiye
1 shared publication - İsMail Demirel
Department of Anaesthesiology and Reanimation, Faculty of Medicine, Firat University, Elazig, Turkey
1 shared publication
Latest Publications
- Open Access
- 31 January 2026
- Published by Springer Nature in Obesity Surgery
- Vol. 36 (3) , 1210-1219
The Impact of Intraoperative Position Changes on Hemodynamics and Cardiac Electrophysiological Balance Index in Patients with Severe Obesity Undergoing Laparoscopic Sleeve Gastrectomy
Background: Pneumoperitoneum and the reverse Trendelenburg (RT) position during laparoscopic sleeve gastrectomy (LSG) can induce autonomic instability and increase the risk of arrhythmias by reducing venous return. This study aimed to evaluate the impact of surgical positioning during LSG on autonomic cardiac function, using hemodynamic parameters and the cardiac electrophysiological balance index (iCEB = QT/QRS) as a biomarker. Methods: This prospective observational study included 66 patients with severe obesity who underwent LSG. Measurements were recorded at five distinct time points, corresponding to specific patient positioning during the procedure: P-baseline (before induction, supine), P1 (after induction, supine), P2 (after pneumoperitoneum, supine), P3 (during pneumoperitoneum, RT), and P4 (after desufflation, RT). Results: Systolic, diastolic, and mean arterial pressures (SAP, DAP, and MAP) significantly decreased at all positions compared to baseline ( p < 0.001 for each). Compared to post-induction (P1), SAP values were substantially higher in the P2 and P4 positions ( p < 0.05, p < 0.001, respectively). Heart rate significantly decreased at P1 compared to baseline ( p < 0.004) and subsequently increased at P2 and P3 relative to P1 ( p < 0.001 and p < 0.009, respectively). A notable increase in iCEB was observed at P4 when compared to P1, P2, and P3 ( p < 0.003, p < 0.001, and p < 0.021, respectively). Despite these changes, iCEB values remained within the reference range across all measured positions. Conclusion: Despite the observed effects of positional changes and pneumoperitoneum on hemodynamic and cardiac electrical parameters during LSG, most patients tolerated these changes well. Crucially, iCEB values remained within the normal reference range throughout the procedure, indicating preserved cardiac autonomic regulation.
- 31 January 2026
- Published by Springer Nature in Obesity Surgery
- Vol. 36 (3) , 1210-1219
Open AccessThe Impact of Intraoperative Position Changes on Hemodynamics and Cardiac Electrophysiological Balance Index in Patients with Severe Obesity Undergoing Laparoscopic Sleeve Gastrectomy
Background: Pneumoperitoneum and the reverse Trendelenburg (RT) position during laparoscopic sleeve gastrectomy (LSG) can induce autonomic instability and increase the risk of arrhythmias by reducing venous return. This study aimed to evaluate the impact of surgical positioning during LSG on autonomic cardiac function, using hemodynamic parameters and the cardiac electrophysiological balance index (iCEB = QT/QRS) as a biomarker. Methods: This prospective observational study included 66 patients with severe obesity who underwent LSG. Measurements were recorded at five distinct time points, corresponding to specific patient positioning during the procedure: P-baseline (before induction, supine), P1 (after induction, supine), P2 (after pneumoperitoneum, supine), P3 (during pneumoperitoneum, RT), and P4 (after desufflation, RT). Results: Systolic, diastolic, and mean arterial pressures (SAP, DAP, and MAP) significantly decreased at all positions compared to baseline ( p < 0.001 for each). Compared to post-induction (P1), SAP values were substantially higher in the P2 and P4 positions ( p < 0.05, p < 0.001, respectively). Heart rate significantly decreased at P1 compared to baseline ( p < 0.004) and subsequently increased at P2 and P3 relative to P1 ( p < 0.001 and p < 0.009, respectively). A notable increase in iCEB was observed at P4 when compared to P1, P2, and P3 ( p < 0.003, p < 0.001, and p < 0.021, respectively). Despite these changes, iCEB values remained within the reference range across all measured positions. Conclusion: Despite the observed effects of positional changes and pneumoperitoneum on hemodynamic and cardiac electrical parameters during LSG, most patients tolerated these changes well. Crucially, iCEB values remained within the normal reference range throughout the procedure, indicating preserved cardiac autonomic regulation.