Marjory Elizabeth Vaca Zapata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marjory Elizabeth Vaca Zapata has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Karina Maria Salvatore Freitas
Department of Orthodontics, Ingá University Center UNINGÁ, Maringá, Brazil
4 shared publications - Mauricio Aguirre Balseca
Department of Health Sciences, University of the Hemispheres, Quito, Ecuador
4 shared publications - Yalil Augusto Rodríguez-Cárdenas
DDS, MSc, PhD. Assistant Professor of the Division of Oral and Maxillofacial Radiology, Faculty of Dentistry, Universidad Nacional de Colombia, Bogotá D.C, Colombia
2 shared publications - Alex Dario Ganan
University of the Hemispheres
1 shared publication - Carmen Yolanda Salazar Hoyos
Department of Orthodontics, University of the Hemispheres, Quito, Ecuador
1 shared publication - Diana Carolina Guevara Castro
University of the Hemispheres
1 shared publication
Latest Publications
- 23 May 2026
- Published by Elsevier in Journal of the World Federation of Orthodontists
- Vol. 15 (4) , 310-319
Tricortical versus paramedian bicortical palatal anchorage in maxillary atresia: A CBCT study
- 23 May 2026
- Published by Elsevier in Journal of the World Federation of Orthodontists
- Vol. 15 (4) , 310-319
Tricortical versus paramedian bicortical palatal anchorage in maxillary atresia: A CBCT study
- Open Access
- 22 May 2026
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 13, 425-429
Effect of fluoride toothpastes on surface roughness of nickel–titanium wires: an in vitro study
Objective: The main objective of this in vitro study was to determine the effect of toothbrushing with fluoride and natural fluoride-free toothpastes on surface roughness changes of nickel-titanium (NiTi) wires as an indirect indicator of corrosion-related surface degradation. Materials and Methods: Thirty rectangular superelastic NiTi wires (0.019 × 0.025”, 20 mm length; Orthometric) were randomly assigned to three groups (n = 10 each): Group 1 – fluoride toothpaste with brushing; Group 2 – fluoride toothpaste without brushing; Group 3 – fluoride-free toothpaste with brushing. Brushing was simulated with an electric toothbrush twice daily for 1 min over 28 days (cumulative 1 h). Initial and final surface roughness (Rz, µm) was measured using a portable roughness tester. Data were analyzed using paired Student’s t-test and ANOVA with Tukey post hoc comparisons (p < 0.05). Results: Significant increases in surface roughness were observed in Group 1 (0.717 ± 0.085 to 2.440 ± 0.225 µm; p < 0.001) and Group 2 (0.791 ± 0.082 to 1.904 ± 0.247 µm; p < 0.001). In contrast, Group 3 showed only a slight and non-significant increase in surface roughness (p = 0.167). Intergroup analysis revealed significant post-treatment differences (p < 0.001), with Tukey’s test distinguishing three subsets: Group 1 > Group 2 > Group 3. Conclusions: Fluoride-containing toothpaste, particularly when combined with brushing, significantly increased surface roughness of NiTi wires, likely due to fluoride-induced degradation of the protective titanium oxide layer, which increases susceptibility to surface deterioration. Clinically, these findings suggest that fluoride-free formulations may represent a safer alternative for orthodontic patients requiring prolonged use of NiTi wires.
- 22 May 2026
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 13, 425-429
Open AccessEffect of fluoride toothpastes on surface roughness of nickel–titanium wires: an in vitro study
Objective: The main objective of this in vitro study was to determine the effect of toothbrushing with fluoride and natural fluoride-free toothpastes on surface roughness changes of nickel-titanium (NiTi) wires as an indirect indicator of corrosion-related surface degradation. Materials and Methods: Thirty rectangular superelastic NiTi wires (0.019 × 0.025”, 20 mm length; Orthometric) were randomly assigned to three groups (n = 10 each): Group 1 – fluoride toothpaste with brushing; Group 2 – fluoride toothpaste without brushing; Group 3 – fluoride-free toothpaste with brushing. Brushing was simulated with an electric toothbrush twice daily for 1 min over 28 days (cumulative 1 h). Initial and final surface roughness (Rz, µm) was measured using a portable roughness tester. Data were analyzed using paired Student’s t-test and ANOVA with Tukey post hoc comparisons (p < 0.05). Results: Significant increases in surface roughness were observed in Group 1 (0.717 ± 0.085 to 2.440 ± 0.225 µm; p < 0.001) and Group 2 (0.791 ± 0.082 to 1.904 ± 0.247 µm; p < 0.001). In contrast, Group 3 showed only a slight and non-significant increase in surface roughness (p = 0.167). Intergroup analysis revealed significant post-treatment differences (p < 0.001), with Tukey’s test distinguishing three subsets: Group 1 > Group 2 > Group 3. Conclusions: Fluoride-containing toothpaste, particularly when combined with brushing, significantly increased surface roughness of NiTi wires, likely due to fluoride-induced degradation of the protective titanium oxide layer, which increases susceptibility to surface deterioration. Clinically, these findings suggest that fluoride-free formulations may represent a safer alternative for orthodontic patients requiring prolonged use of NiTi wires.
- Open Access
- 15 April 2026
- Published by Taylor & Francis in Clinical and Investigative Orthodontics
- p. 1-9
Condylar morphology and volume comparison in different skeletal classes: a CBCT study
- 15 April 2026
- Published by Taylor & Francis in Clinical and Investigative Orthodontics
- p. 1-9
Open AccessCondylar morphology and volume comparison in different skeletal classes: a CBCT study
- Open Access
- 23 March 2026
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 13, 141-146
Effect of salivary pH variations on the adhesive performance of Transbond XT and Orthocem in orthodontic bracket bonding
Objective: This in vitro study aimed to evaluate the shear bond strength of orthodontic brackets bonded to acrylic resin specimens with two adhesive systems, Transbond XT and Orthocem, under different salivary pH levels (4, 5, 6, and 7). Materials and methods: A total of 120 acrylic resin specimens (Brava Block®, FGM) were prepared and randomly assigned to three groups: control bonded with Transbond XT and Orthocem with no salivary exposure (n = 24), Transbond XT (n = 48), and Orthocem (n = 48). Each adhesive group was subdivided and immersed in artificial saliva at pH 4, 5, 6, or 7 for 30 days. Metal premolar brackets (Vector+ Roth prescription, Aditek®) were bonded following manufacturers’ protocols and subjected to shear bond strength testing using a Universal Testing Machine, following ISO 4049 standards. Data were analyzed with Analysis of Variance (ANOVA), t-test, and Tukey tests at a significance level of p < 0.05. Results: Transbond XT consistently showed higher bond strength than Orthocem across all pH levels. Maximum resistance was observed at pH 7 (21.19 ± 5.06 MPa), followed by the control group (19.64 ± 5.28 MPa). Orthocem demonstrated significantly lower values, ranging from 9.51 ± 3.87 MPa (pH 5) to 4.94 ± 2.15 MPa (pH 6). Acidic conditions reduced the bond strength of both adhesives, but Transbond XT maintained clinically reliable values, while Orthocem was more susceptible to performance decline at moderately acidic levels. Conclusions: Salivary pH directly influenced adhesive performance. Transbond XT demonstrated superior resistance under all conditions, whereas Orthocem showed lower but still clinically acceptable shear bond strength values, except at pH 6, where a marked decrease was observed.
- 23 March 2026
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 13, 141-146
Open AccessEffect of salivary pH variations on the adhesive performance of Transbond XT and Orthocem in orthodontic bracket bonding
Objective: This in vitro study aimed to evaluate the shear bond strength of orthodontic brackets bonded to acrylic resin specimens with two adhesive systems, Transbond XT and Orthocem, under different salivary pH levels (4, 5, 6, and 7). Materials and methods: A total of 120 acrylic resin specimens (Brava Block®, FGM) were prepared and randomly assigned to three groups: control bonded with Transbond XT and Orthocem with no salivary exposure (n = 24), Transbond XT (n = 48), and Orthocem (n = 48). Each adhesive group was subdivided and immersed in artificial saliva at pH 4, 5, 6, or 7 for 30 days. Metal premolar brackets (Vector+ Roth prescription, Aditek®) were bonded following manufacturers’ protocols and subjected to shear bond strength testing using a Universal Testing Machine, following ISO 4049 standards. Data were analyzed with Analysis of Variance (ANOVA), t-test, and Tukey tests at a significance level of p < 0.05. Results: Transbond XT consistently showed higher bond strength than Orthocem across all pH levels. Maximum resistance was observed at pH 7 (21.19 ± 5.06 MPa), followed by the control group (19.64 ± 5.28 MPa). Orthocem demonstrated significantly lower values, ranging from 9.51 ± 3.87 MPa (pH 5) to 4.94 ± 2.15 MPa (pH 6). Acidic conditions reduced the bond strength of both adhesives, but Transbond XT maintained clinically reliable values, while Orthocem was more susceptible to performance decline at moderately acidic levels. Conclusions: Salivary pH directly influenced adhesive performance. Transbond XT demonstrated superior resistance under all conditions, whereas Orthocem showed lower but still clinically acceptable shear bond strength values, except at pH 6, where a marked decrease was observed.