GSG. Soucail

G. Soucail

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


G. Soucail has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Exploring the gravitationally lensed system HE1104-1805: VLT spectroscopy of the lens at z=0.729

    by C. Lidman, F. Courbin, J. -P. Kneib, G. Golse, F. Castander, G. Soucail

    Using FORS2, mounted on Kueyen (UT2 of the VLT), we have obtained the redshift of the lensing galaxy in the gravitational lens system HE1104-1805. We measure z=0.729, in good agreement with previous estimates based on the time delay and the position of the lens on the fundamental plane. It also coincides with one of the metal line absorption systems that are seen in high resolution spectra of HE1104-1805.

  • Open Access

    X-ray observations and mass determinations in the cluster of galaxies Cl0024+17

    by G. Soucail, N. Ota, H. Bohringer, O. Czoske, M. Hattori, Y. Mellier

    We present a detailed analysis of the mass distribution in the rich and distant cluster of galaxies Cl0024+17. X-ray data come from both a deep ROSAT/HRI image of the field (Bohringer et al. 1999) and ASCA spectral data. Using a wide field CCD image of the cluster, we optically identify all the faint X-ray sources, whose counts are compatible with deep X-ray number counts. In addition we marginally detect the X-ray counter-part of the gravitational shear perturbation detected by Bonnet et al. (1994) at a 2.5 $\sigma$ level. A careful spectral analysis of ASCA data is also presented. In particular, we extract a low resolution spectrum of the cluster free from the contamination by a nearby point source located 1.2 arcmin from the center. The X-ray temperature deduced from this analysis is $T_X = 5.7 ^{+4.9}_{-2.1}$ keV at the 90% confidence level. The comparison between the mass derived from a standard X-ray analysis and from other methods such as the Virial Theorem or the gravitational lensing effect lead to a mass discrepancy of a factor 1.5 to 3. We discuss all the possible sources of uncertainties in each method of mass determination and give some indications on the way to reduce them. A complementary study of optical data is in progress and may solve the X-ray/optical discrepancy through a better understanding of the dynamics of the cluster.