Felice D’ARco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felice D’ARco has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Annalena Lange
Department of Neuroradiology, University Hospital Bonn, Germany
2 shared publications - Theodor Rüber
Department of Neuroradiology University Hospital Bonn Bonn Germany
2 shared publications - Abdul Kareem Pullattayil
Queens Library, Queen’s University, Kingston, Ontario, Canada
1 shared publication - Andrea Dell’orco
Charité – Universitätsmedizin Berlin, corporate member of FreieUniversität Berlin and Humboldt-Universität zu Berlin, Institute ofNeuroradiology, Berlin, Germany
1 shared publication - Angela M. Kaindl
Department of Pediatric Neurology, Charité – Universitätsmedizin Berlin, Germany
1 shared publication - Anna Elisabetta Vaudano
Unità di Neurofisiologia e Centro Epilessia, Azienda Ospedaliero‐Universitaria di Modena, Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze Università di Modena e Reggio‐Emilia Modena Italy
1 shared publication
Latest Publications
- Open Access
Multi-centre validation of MELD-graph for automated focal cortical dysplasia detection using 7T compared to paired 3T MRI
Background: Software tools can support MRI diagnosis of focal cortical dysplasias (FCDs) – subtle, surgically-treatable lesions that underlie drug-resistant focal epilepsy (DRFE). MELD-graph, a widely used open-source tool combining surface-based morphometry with a convolutional neural network, was developed using 1.5T and 3T MRI data. 7T MRI is increasingly used for lesion detection in DRFE. This study investigated whether MELD-graph is robust to domain shift at 7T. Methods: We collated paired 3T and 7T T1-weighted MRI, and FLAIR where available, from 23 patients with FCD (6 histologically-verified, 17 identified radiologically) and 39 healthy controls at four epilepsy centres. Manual lesion labels were used as ground truth. MELD-graph was run on 3T images, on 7T images with the default pipeline, and on 7T images with adaptations for 7T MRI (SPM bias-field correction, SynthStrip skull-stripping, sub-millimetric FreeSurfer reconstruction), with and without ComBat harmonisation. FCD detection performance and surface morphometry features were compared. Results: Sensitivity for FCD detection was 65% (15/23) at 3T, 48% (11/23) for 7T default and 52% (12/23) for 7T adapted, with Combat harmonisation. Among radiologically 3T-negative patients, 2/8 were detected at 3T and 3/8 at 7T; and among histologically confirmed FCD, 3/6 at 3T and 1/6 at 7T. Specificity was significantly lower at 7T (default 39%, adapted 45%) than 3T (76%). False-positives predominantly occurred in the basal temporal lobes. ComBat harmonisation improved specificity in all conditions and largely compensated for field-strength dependent differences in surface morphometry features. Adding FLAIR at 7T increased false-positive predictions. Conclusion: Sensitivity is comparable but specificity of MELD-graph is lower at 7T compared to 3T. Adaptations for 7T MRI can reduce segmentation errors but do not significantly improve FCD detection, while harmonisation improves performance. The adapted pipeline is released open-source. 7T MELD-graph outputs may inform radiologist review in challenging cases but require cautious interpretation.
Open AccessMulti-centre validation of MELD-graph for automated focal cortical dysplasia detection using 7T compared to paired 3T MRI
Background: Software tools can support MRI diagnosis of focal cortical dysplasias (FCDs) – subtle, surgically-treatable lesions that underlie drug-resistant focal epilepsy (DRFE). MELD-graph, a widely used open-source tool combining surface-based morphometry with a convolutional neural network, was developed using 1.5T and 3T MRI data. 7T MRI is increasingly used for lesion detection in DRFE. This study investigated whether MELD-graph is robust to domain shift at 7T. Methods: We collated paired 3T and 7T T1-weighted MRI, and FLAIR where available, from 23 patients with FCD (6 histologically-verified, 17 identified radiologically) and 39 healthy controls at four epilepsy centres. Manual lesion labels were used as ground truth. MELD-graph was run on 3T images, on 7T images with the default pipeline, and on 7T images with adaptations for 7T MRI (SPM bias-field correction, SynthStrip skull-stripping, sub-millimetric FreeSurfer reconstruction), with and without ComBat harmonisation. FCD detection performance and surface morphometry features were compared. Results: Sensitivity for FCD detection was 65% (15/23) at 3T, 48% (11/23) for 7T default and 52% (12/23) for 7T adapted, with Combat harmonisation. Among radiologically 3T-negative patients, 2/8 were detected at 3T and 3/8 at 7T; and among histologically confirmed FCD, 3/6 at 3T and 1/6 at 7T. Specificity was significantly lower at 7T (default 39%, adapted 45%) than 3T (76%). False-positives predominantly occurred in the basal temporal lobes. ComBat harmonisation improved specificity in all conditions and largely compensated for field-strength dependent differences in surface morphometry features. Adding FLAIR at 7T increased false-positive predictions. Conclusion: Sensitivity is comparable but specificity of MELD-graph is lower at 7T compared to 3T. Adaptations for 7T MRI can reduce segmentation errors but do not significantly improve FCD detection, while harmonisation improves performance. The adapted pipeline is released open-source. 7T MELD-graph outputs may inform radiologist review in challenging cases but require cautious interpretation.
- Open Access
Deep Learning-Based Detection of Focal Cortical Dysplasia in Children: External Validation of the MELD Graph and 3D-nnUNet pipelines
Focal cortical dysplasias (FCDs) are one of the most common structural causes of drug-resistant epilepsy in children but are frequently subtle and difficult to detect on conventional MRI. Many automated lesion detection methods have therefore been proposed to support neuroradiological assessment. In this study, we externally validated two recently developed deep-learning approaches for FCD detection, MELD Graph and 3D-nnUNet, in a pediatric cohort. In this retrospective single-center study, brain MRI scans of 71 children evaluated for epilepsy were analyzed, including 35 MRI-positive patients with suspected FCD and 36 MRI-negative cases based on the primary radiology reports. Both models were applied to standard 3D T1-weighted and 3D FLAIR images. Detected lesions were reviewed by an experienced pediatric neuroradiologist and classified as true positive, false positive, or false negative. Clinical semiology and EEG findings were additionally evaluated for cases with false-positive detections. At the lesion level, MELD Graph achieved a precision of 0.85 and recall of 0.52, while 3D-nnUNet achieved a precision of 0.91 and recall of 0.48. In the MRI-negative patients, MELD Graph produced more false-positive detections than 3D-nnUNet (0.53 vs. 0.14 false-positive lesions per patient). At the patient level, MELD Graph showed slightly higher sensitivity than 3D-nnUNet (0.63 vs. 0.54), whereas 3D-nnUNet demonstrated markedly higher specificity (0.86 vs. 0.56). Improved FLAIR image quality was associated with trends toward improved model performance. Both models demonstrated high precision but moderate sensitivity, indicating that they are valuable decision-support tools but cannot replace expert neuroradiological evaluation. Optimized MRI acquisition protocols are needed to further improve automated lesion detection in pediatric epilepsy.
Open AccessDeep Learning-Based Detection of Focal Cortical Dysplasia in Children: External Validation of the MELD Graph and 3D-nnUNet pipelines
Focal cortical dysplasias (FCDs) are one of the most common structural causes of drug-resistant epilepsy in children but are frequently subtle and difficult to detect on conventional MRI. Many automated lesion detection methods have therefore been proposed to support neuroradiological assessment. In this study, we externally validated two recently developed deep-learning approaches for FCD detection, MELD Graph and 3D-nnUNet, in a pediatric cohort. In this retrospective single-center study, brain MRI scans of 71 children evaluated for epilepsy were analyzed, including 35 MRI-positive patients with suspected FCD and 36 MRI-negative cases based on the primary radiology reports. Both models were applied to standard 3D T1-weighted and 3D FLAIR images. Detected lesions were reviewed by an experienced pediatric neuroradiologist and classified as true positive, false positive, or false negative. Clinical semiology and EEG findings were additionally evaluated for cases with false-positive detections. At the lesion level, MELD Graph achieved a precision of 0.85 and recall of 0.52, while 3D-nnUNet achieved a precision of 0.91 and recall of 0.48. In the MRI-negative patients, MELD Graph produced more false-positive detections than 3D-nnUNet (0.53 vs. 0.14 false-positive lesions per patient). At the patient level, MELD Graph showed slightly higher sensitivity than 3D-nnUNet (0.63 vs. 0.54), whereas 3D-nnUNet demonstrated markedly higher specificity (0.86 vs. 0.56). Improved FLAIR image quality was associated with trends toward improved model performance. Both models demonstrated high precision but moderate sensitivity, indicating that they are valuable decision-support tools but cannot replace expert neuroradiological evaluation. Optimized MRI acquisition protocols are needed to further improve automated lesion detection in pediatric epilepsy.
- Open Access
Recommendations for structural magnetic resonance imaging in infants with first afebrile seizure or new onset epilepsy: Evidence‐based recommendations from the ILAE Neuroimaging Task Force
Infants aged 1–24 months with new onset epilepsy frequently present with structural brain abnormalities, yet no updated evidence‐based magnetic resonance imaging (MRI) guidelines exist for this population. The International League Against Epilepsy (ILAE) Neuroimaging Task Force developed evidence‐based recommendations for structural brain MRI in infants with a first afebrile seizure or new onset epilepsy. A multidisciplinary panel defined three PICO (patients, intervention, comparison group, outcome under consideration) questions, conducted a systematic review (PROSPERO [Prospective Register of Systematic Reviews] CRD42024592653), and reported the results in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‐Analyses) 2020 guidelines. Risk of bias was evaluated using the JBI (Joanna Briggs Institute) checklist. GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) methodology was used to assess certainty of evidence and formulate recommendations for the following: (1) the effectiveness of MRI in identifying underlying etiologies, (2) clinical predictors of MRI abnormalities, and (3) MRI protocols. Seventeen studies ( n = 1209) were included. Among 753 infants who underwent MRI, 438 (58.2%) had abnormal findings. Despite heterogeneity in MRI protocols and reporting, the evidence supports the utility of MRI in this population. Specific clinical features (focal seizure semiology, abnormal neurological examination, seizure duration > 5 min, focal electroencephalographic abnormalities, developmental delay, and perinatal complications) were associated with abnormal MRI findings, although methodological limitations reduce certainty. Only six studies provided data on MRI sequences; however, none reported findings specifically in relation to the diagnostic accuracy or yield of individual protocols, precluding the development of evidence‐based recommendations on MRI protocol selection. MRI is conditionally recommended in all infants with a first afebrile seizure or new onset epilepsy. MRI could be prioritized in those with specific clinical features indicative of higher likelihood of abnormal findings. Recommendations are based on very low certainty of evidence. These are the first ILAE‐endorsed, evidence‐based recommendations for MRI in infants with first afebrile seizure or new onset epilepsy. Further prospective studies with standardized protocols are needed to refine MRI indications and optimize diagnostic yield in this age group.
Open AccessRecommendations for structural magnetic resonance imaging in infants with first afebrile seizure or new onset epilepsy: Evidence‐based recommendations from the ILAE Neuroimaging Task Force
Infants aged 1–24 months with new onset epilepsy frequently present with structural brain abnormalities, yet no updated evidence‐based magnetic resonance imaging (MRI) guidelines exist for this population. The International League Against Epilepsy (ILAE) Neuroimaging Task Force developed evidence‐based recommendations for structural brain MRI in infants with a first afebrile seizure or new onset epilepsy. A multidisciplinary panel defined three PICO (patients, intervention, comparison group, outcome under consideration) questions, conducted a systematic review (PROSPERO [Prospective Register of Systematic Reviews] CRD42024592653), and reported the results in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‐Analyses) 2020 guidelines. Risk of bias was evaluated using the JBI (Joanna Briggs Institute) checklist. GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) methodology was used to assess certainty of evidence and formulate recommendations for the following: (1) the effectiveness of MRI in identifying underlying etiologies, (2) clinical predictors of MRI abnormalities, and (3) MRI protocols. Seventeen studies ( n = 1209) were included. Among 753 infants who underwent MRI, 438 (58.2%) had abnormal findings. Despite heterogeneity in MRI protocols and reporting, the evidence supports the utility of MRI in this population. Specific clinical features (focal seizure semiology, abnormal neurological examination, seizure duration > 5 min, focal electroencephalographic abnormalities, developmental delay, and perinatal complications) were associated with abnormal MRI findings, although methodological limitations reduce certainty. Only six studies provided data on MRI sequences; however, none reported findings specifically in relation to the diagnostic accuracy or yield of individual protocols, precluding the development of evidence‐based recommendations on MRI protocol selection. MRI is conditionally recommended in all infants with a first afebrile seizure or new onset epilepsy. MRI could be prioritized in those with specific clinical features indicative of higher likelihood of abnormal findings. Recommendations are based on very low certainty of evidence. These are the first ILAE‐endorsed, evidence‐based recommendations for MRI in infants with first afebrile seizure or new onset epilepsy. Further prospective studies with standardized protocols are needed to refine MRI indications and optimize diagnostic yield in this age group.