Ondrej Straka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ondrej Straka has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jarmila Pavlovicova
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, 841 04 Bratislava, Slovakia
1 shared publication - Michal Kovac
Slovak University of Technology in Bratislava
1 shared publication Peter Macsik
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Bratislava, Slovak Republic
1 shared publication- Veronika Kurilova
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, 841 04 Bratislava, Slovakia
1 shared publication Zlatica Fellner
Faculty of Medicine, Slovak Medical University in Bratislava, Bratislava, Slovak Republic
1 shared publication
Latest Publications
- Open Access
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 47800-47815
Unconditional GAN-Based Generation of Stage-Specific Fundus Images for Augmenting Diabetic Retinopathy Screening
Class imbalance in diabetic retinopathy (DR) datasets, particularly the underrepresentation of advanced stages such as proliferative DR, limits classifier performance and necessitates specialized augmentation strategies. This study presents a data augmentation approach using StyleGAN2-ADAto generate stage-specific synthetic fundus images. Unlike conditional approaches requiring labels or segmentation masks, our method trains separate unconditional models for each DR severity stage, producing anatomically realistic images while preserving pathological characteristics. We propose a comprehensive evaluation framework comprising three components: quantitative assessment using distribution-based metrics (FID, KID, IS) and nearest-neighbor-based metrics (NN-SSIM, NN-PSNR); task-based evaluation through DR classification experiments with ConvNeXt Tiny, MobileNet V3 Small, and Xception architectures; and expert validation by three ophthalmologists assessing clinical plausibility. Classification experiments demonstrated improvements in overall accuracy, with ConvNeXt Tiny achieving 73.48% accuracy (+1.82% over baseline) when combining synthetic and classical augmentation. Inter-rater reliability analysis (κ = 0.723 between two evaluators) confirmed the clinical realism of generated images. Our unconditional StyleGAN2-ADA approach provides a scalable, mask-free augmentation solution addressing class imbalance in fundus imaging datasets, potentially enhancing DR screening systems in resource-constrained clinical settings.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 47800-47815
Open AccessUnconditional GAN-Based Generation of Stage-Specific Fundus Images for Augmenting Diabetic Retinopathy Screening
Class imbalance in diabetic retinopathy (DR) datasets, particularly the underrepresentation of advanced stages such as proliferative DR, limits classifier performance and necessitates specialized augmentation strategies. This study presents a data augmentation approach using StyleGAN2-ADAto generate stage-specific synthetic fundus images. Unlike conditional approaches requiring labels or segmentation masks, our method trains separate unconditional models for each DR severity stage, producing anatomically realistic images while preserving pathological characteristics. We propose a comprehensive evaluation framework comprising three components: quantitative assessment using distribution-based metrics (FID, KID, IS) and nearest-neighbor-based metrics (NN-SSIM, NN-PSNR); task-based evaluation through DR classification experiments with ConvNeXt Tiny, MobileNet V3 Small, and Xception architectures; and expert validation by three ophthalmologists assessing clinical plausibility. Classification experiments demonstrated improvements in overall accuracy, with ConvNeXt Tiny achieving 73.48% accuracy (+1.82% over baseline) when combining synthetic and classical augmentation. Inter-rater reliability analysis (κ = 0.723 between two evaluators) confirmed the clinical realism of generated images. Our unconditional StyleGAN2-ADA approach provides a scalable, mask-free augmentation solution addressing class imbalance in fundus imaging datasets, potentially enhancing DR screening systems in resource-constrained clinical settings.