Ali Habib Akhyari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Ali Habib Akhyari has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Andrea P. Arguelles
Materials Research Institute The Pennsylvania State University University Park Pennsylvania USA
1 shared publication - Chi-Luen Huang
Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publication - Kae Nakamura
Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publication - Susan Trolier-McKinstry
Pennsylvania State University
1 shared publication - Thomas N. Jackson
School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publication
Latest Publications
- Open Access
PiezoMEMS Fabrication on Flexible Stainless-Steel Substrates
A bottom-up fabrication approach for flexible piezoelectric micromachined ultrasound transducer (PMUT) arrays on stainless-steel substrates was developed. Devices were fabricated using chemical solution deposition of a 700 nm-thick layer of Pb0.99□0.01(Zr0.52Ti0.48)Nb0.02O3, where □ denotes a vacancy on the Pb site, on 50 μm-thick LaNiO3/HfO2/stainless-steel foils. Lithography for definition of the electrode and piezoelectric layers was completed on the front of the wafer. Ni electroplating on the back side of the foil was used to create locally stiff areas to define the deflection area. PMUT devices were successfully fabricated using this method. The permittivity and loss tangent of the fabricated device at 1 kHz were 283 ± 9 and 2.
Open AccessPiezoMEMS Fabrication on Flexible Stainless-Steel Substrates
A bottom-up fabrication approach for flexible piezoelectric micromachined ultrasound transducer (PMUT) arrays on stainless-steel substrates was developed. Devices were fabricated using chemical solution deposition of a 700 nm-thick layer of Pb0.99□0.01(Zr0.52Ti0.48)Nb0.02O3, where □ denotes a vacancy on the Pb site, on 50 μm-thick LaNiO3/HfO2/stainless-steel foils. Lithography for definition of the electrode and piezoelectric layers was completed on the front of the wafer. Ni electroplating on the back side of the foil was used to create locally stiff areas to define the deflection area. PMUT devices were successfully fabricated using this method. The permittivity and loss tangent of the fabricated device at 1 kHz were 283 ± 9 and 2.