AAAbedalrahman Yazan Aljarrah

Abedalrahman Yazan Aljarrah

*This is an algorithmically generated author record based on publicly available information.

Abedalrahman Yazan Aljarrah has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction: From laparoscopy to robotics in living donor hepatectomy: a systematic review and meta-analysis of comparative outcomes

    by Mohamed Al Sayed, Mahmoud Albashier, Hashem Altabbaa, Ahmad Omar Saleh, Abdalla M. Hadhoud, Mahmoud Ashraf Hussein, Abedalrahman Yazan Aljarrah, Menatalla M. Abdelrazek, Mohamed Bekheit

  • Open Access

    From laparoscopy to robotics in living donor hepatectomy: a systematic review and meta-analysis of comparative outcomes

    by Mohamed Al Sayed, Mahmoud Albashier, Hashem Altabbaa, Ahmad Omar Saleh, Abdalla M. Hadhoud, Mahmoud Ashraf Hussein, Abedalrahman Yazan Aljarrah, Menatalla M. Abdelrazek, Mohamed Bakhiet

    Minimally invasive approaches have become integral to adult living donor hepatectomy, where protection of donor safety is paramount. Both laparoscopic and robotic techniques are increasingly implemented in specialized transplant centers for various graft types, including right lobe, left lobe, and left lateral sectionectomy. In this context, we conducted a systematic review and meta-analysis to synthesize the current evidence comparing robotic and laparoscopic living donor hepatectomy in adult liver transplantation. The analysis primarily focused on right lobe procurement while acknowledging that several large registry-based studies included mixed graft types. The methodology and reporting of this study followed the PRISMA 2020 statement, and the protocol was prospectively registered in the PROSPERO database. Electronic databases were systematically searched through December 2025 to identify comparative studies evaluating robotic and laparoscopic hepatectomy in adult living donors. Operative, donor, and recipient outcomes were synthesized using random-effects meta-analytic models. Methodological quality was appraised with the ROBINS-I tool, and the overall strength of evidence was graded using the GRADE framework. Seven comparative studies published between 2022 and 2025, comprising more than 15,000 adult living donors, met inclusion criteria. Baseline demographic and clinical characteristics were broadly similar across surgical approaches. Robotic donor hepatectomy was associated with a lower likelihood of perioperative transfusion (RR 0.27, 95% CI 0.09–0.76; p = 0.013) and a reduced incidence of overall donor morbidity (RR 0.47, 95% CI 0.25–0.89; p = 0.020) compared with laparoscopy. No significant differences were observed in major donor complications or mortality. Although operative duration was longer with the robotic technique, intraoperative blood loss was lower. Among recipients, robotic graft procurement was associated with reduced overall morbidity and fewer biliary complications, whereas vascular events and mortality were comparable between approaches. Robotic living donor hepatectomy appears to enhance donor safety, with lower transfusion rates and reduced overall morbidity, while maintaining comparable rates of major complications and mortality. These results suggest a potential advantage for the robotic approach in appropriately experienced centers. Nevertheless, confirmation through large, rigorously designed randomized trials is required to establish definitive comparative effectiveness and to clarify the optimal minimally invasive strategy. Registration: PROSPERO CRD420261299554.

  • Open Access

    Short-term outcomes of robotic versus laparoscopic TAPP for inguinal hernia repair: a systematic review, meta-analysis, and GRADE assessment

    by Mohamed H. Zidan, Mohamed AlSayed, Mario Maged, Hashem Altabbaa, Abdalla M. Hadhoud, Mahmoud Ashraf Hussein, Abedalrahman Yazan Aljarrah, Mohamed Hany, Ahmed Amgad, Mahmoud Albashier

    Robotic transabdominal preperitoneal (R-TAPP) repair has gained increasing adoption in inguinal hernia surgery, yet its short-term clinical value relative to conventional laparoscopic TAPP (L-TAPP) remains debated. Although robotic platforms offer technical and ergonomic advantages, whether these translate into measurable patient-centered benefits is uncertain. This systematic review and meta-analysis aimed to provide an updated comparative evaluation of short-term safety, efficacy, economic impact, and surgeon workload between R-TAPP and L-TAPP. A systematic review adhering to PRISMA 2020 standards was conducted across five major databases from inception through September 2025. Randomized controlled trials and comparative observational studies involving adult patients undergoing R-TAPP or L-TAPP were included. The primary endpoint was chronic postoperative inguinal pain. Secondary outcomes comprised operative duration, estimated blood loss, length of hospital stay, postoperative complications, recurrence, readmission, reoperation, urinary outcomes, surgical site infection, procedural costs, and surgeon workload assessed using the NASA Task Load Index (NASA-TLX). Risk of bias was evaluated using RoB 2 and ROBINS-I tools, and pooled analyses were performed using random-effects models. Fourteen independent studies (3 randomized trials and 11 cohort studies) encompassing 5,520 patients met the inclusion criteria. The incidence of chronic postoperative pain ( n = 616) did not differ significantly between approaches (RR 0.58; 95% CI 0.30–1.12; p = 0.11; I² = 0%). Robotic repair was associated with prolonged operative time (MD 10.93 min; 95% CI 4.18–17.67; p = 0.002). No statistically significant differences were observed in blood loss, hospital stay, overall morbidity, recurrence, readmission, reoperation, urinary retention, urinary tract infection, or surgical site infection. While total NASA-TLX scores were comparable, robotic surgery significantly reduced the surgeon’s physical workload. Procedural costs were consistently higher in the robotic cohort. R-TAPP provides short-term clinical outcomes comparable to L-TAPP but is associated with longer operative times and increased direct costs. Its principal advantage appears to lie in improved surgeon ergonomics rather than superior patient outcomes. Robotic repair may therefore be most appropriate in complex cases or high-volume centers with established expertise, whereas laparoscopic TAPP remains a cost-efficient standard for routine inguinal hernia repair.