Eleonora Pasino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eleonora Pasino has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Lombardi
CERN, The European Organisation for Nuclear Research, 1211 Meyrin, Switzerland
1 shared publication - Aristeidis Mamaras
CERN, Geneva
1 shared publication - Dimitrios Sampsonidis
Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
1 shared publication - Francesco Di Lorenzo
European Organization for Nuclear Research (CERN), 1211 Meyrin, Geneva, Switzerland
1 shared publication
Latest Publications
- Open Access
- 6 April 2026
- Published by MDPI AG in Instruments
- Vol. 10 (2) , 22
Design and Characterization of a Low-Current Compact Extraction and Matching System for a High-Frequency RFQ in Medical Applications
A low-current compact extraction and matching system has been designed and experimentally tested to evaluate its capability for direct proton injection of 15 keV into a 750 MHz radiofrequency quadrupole for medical applications. The design methodology combined 2D and 3D layouts, supported by detailed electrostatic simulations. First experimental results are reported, including beam current characterization and irradiation measurements under varying operating conditions. These results are benchmarked against simulation data to provide a preliminary evaluation of system performance. Ongoing efforts focus on extending the experimental campaign to consolidate these findings. A comparative study with a gridded-lens-based extraction and transport system is also being conducted to achieve reliable matching of high-quality beams to high-frequency RFQs for clinical implementation.
- 6 April 2026
- Published by MDPI AG in Instruments
- Vol. 10 (2) , 22
Open AccessDesign and Characterization of a Low-Current Compact Extraction and Matching System for a High-Frequency RFQ in Medical Applications
A low-current compact extraction and matching system has been designed and experimentally tested to evaluate its capability for direct proton injection of 15 keV into a 750 MHz radiofrequency quadrupole for medical applications. The design methodology combined 2D and 3D layouts, supported by detailed electrostatic simulations. First experimental results are reported, including beam current characterization and irradiation measurements under varying operating conditions. These results are benchmarked against simulation data to provide a preliminary evaluation of system performance. Ongoing efforts focus on extending the experimental campaign to consolidate these findings. A comparative study with a gridded-lens-based extraction and transport system is also being conducted to achieve reliable matching of high-quality beams to high-frequency RFQs for clinical implementation.