Very late-onset pacemaker pocket infection presenting as a giant granulomatous mass
Pacemaker-related infections are most commonly observed during the early postoperative period; however, in rare instances, they may present many years after device implantation. We report an unusual case of a giant granulomatous pacemaker pocket infection occurring 10 years after the initial implantation. The patient presented with localized inflammatory signs without systemic manifestations. Following surgical removal of the device and the associated mass, histopathological examination confirmed xanthogranulomatous inflammation. Staphylococcus epidermidis was isolated from tissue cultures. Complete device extraction combined with prolonged antimicrobial therapy resulted in full clinical resolution, followed by successful contralateral re-implantation. This case highlights the importance of maintaining long-term vigilance in patients with cardiac implantable electronic devices.
- 28 March 2026
- Published by MediHealth Academy in Journal of Cardiology & Cardiovascular Surgery
- Vol. 4 (1) , 25-27
Very late-onset pacemaker pocket infection presenting as a giant granulomatous mass
Pacemaker-related infections are most commonly observed during the early postoperative period; however, in rare instances, they may present many years after device implantation. We report an unusual case of a giant granulomatous pacemaker pocket infection occurring 10 years after the initial implantation. The patient presented with localized inflammatory signs without systemic manifestations. Following surgical removal of the device and the associated mass, histopathological examination confirmed xanthogranulomatous inflammation. Staphylococcus epidermidis was isolated from tissue cultures. Complete device extraction combined with prolonged antimicrobial therapy resulted in full clinical resolution, followed by successful contralateral re-implantation. This case highlights the importance of maintaining long-term vigilance in patients with cardiac implantable electronic devices.