Mianzhi Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mianzhi Zhou has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guanyu Chen
Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, Los Angeles, CA, USA
2 shared publications Jacob Rosen
Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, Los Angeles, CA, USA
1 shared publication- Jacob Rosen
Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, Los Angeles, CA, USA
1 shared publication Peter Walker Ferguson
Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, Los Angeles, CA, USA
1 shared publication- Xiaochen Li
University of California
1 shared publication - Yipeng Huangfu
University of California
1 shared publication
Latest Publications
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (2) , 774-784
Tunnel-Guided Assist-as-Needed Control for Hand Pre-Shaping: Development and Validation in Healthy Participants
Rehabilitating hand function after stroke is challenging, particularly for individuals with spasticity. Grasp preshaping— an anticipatory component of motor control—is often undertrained in conventional therapy. This work introduces a synergy-based assist-as-needed (AAN) framework for preshaping using the Opposable Thumb Hand Exoskeleton for Rehabilitation (OTHER Hand). Desired motion is expressed in a synergy-dependent representation rather than time, with Gaussian Mixture Models and Regression (GMM/GMR) generating smooth, task-specific reference trajectories. Virtual corrective and tangential forces derived from joint errors and velocities adapt motor output to encourage active effort. A pilot study with five healthy participants tested the controller during both unconstrained movement and a simplified impairment condition created via constant feedforward torque. Although not a velocity-dependent model of spasticity, this perturbation provided a controlled proxy for evaluating adaptive assistance. AAN increased user engagement by 57.6% relative to passive position control and improved efficiency—defined as the ratio of user effort to trajectory error—by 10.1%-22.5% higher than for either force feedback or position control across both constraint levels. These results indicate that synergy-based minimal assistance can enhance engagement and performance, supporting its potential for clinical translation.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (2) , 774-784
Tunnel-Guided Assist-as-Needed Control for Hand Pre-Shaping: Development and Validation in Healthy Participants
Rehabilitating hand function after stroke is challenging, particularly for individuals with spasticity. Grasp preshaping— an anticipatory component of motor control—is often undertrained in conventional therapy. This work introduces a synergy-based assist-as-needed (AAN) framework for preshaping using the Opposable Thumb Hand Exoskeleton for Rehabilitation (OTHER Hand). Desired motion is expressed in a synergy-dependent representation rather than time, with Gaussian Mixture Models and Regression (GMM/GMR) generating smooth, task-specific reference trajectories. Virtual corrective and tangential forces derived from joint errors and velocities adapt motor output to encourage active effort. A pilot study with five healthy participants tested the controller during both unconstrained movement and a simplified impairment condition created via constant feedforward torque. Although not a velocity-dependent model of spasticity, this perturbation provided a controlled proxy for evaluating adaptive assistance. AAN increased user engagement by 57.6% relative to passive position control and improved efficiency—defined as the ratio of user effort to trajectory error—by 10.1%-22.5% higher than for either force feedback or position control across both constraint levels. These results indicate that synergy-based minimal assistance can enhance engagement and performance, supporting its potential for clinical translation.