Minh Vu Phuc Ha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minh Vu Phuc Ha has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Nghia Phu Nguyen
School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
3 shared publications - Ai Cao My Bui
School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publications Ai Cao My Bui
Affiliations School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam, Department of Interventional Cardiology, University Medical Center Ho Chi Minh City, Ho Chi Minh City, Vietnam
1 shared publicationAnh Ngoc Minh Bui
Affiliation School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
1 shared publication- Bui The Dung
Affiliation Department of Cardiology, University Medical Center Ho Chi Minh City, Ho Chi Minh City, Vietnam
1 shared publication - Hung Minh Ngo
Department of Interventional Cardiology, Cho Ray Hospital, Ho Chi Minh City, Vietnam; Faculty of Medicine, Nam Can Tho University, Ho Chi Minh City, Vietnam
1 shared publication
Latest Publications
- Open Access
- 2 November 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (11) , e0360957
Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study
Background: Ambulatory blood pressure monitoring (ABPM) is the reference standard for diagnosing hypertension (HTN), but its use in routine practice remains limited because of cost, availability, and patient burden. Automated office blood pressure (AOBP) has been proposed as a practical alternative, although its performance relative to ABPM remains uncertain. Objectives: To evaluate the agreement and diagnostic performance of 30-minute AOBP compared with 24-hour ABPM and to identify optimal cut-off values for detecting ambulatory hypertension. Methods: In this prospective cohort study, 79 adults undergoing ABPM also underwent 30-minute AOBP measurement with automated readings every 5 minutes. The mean of the final six measurements was analyzed. Agreement was assessed using paired comparisons and Bland–Altman analysis. Diagnostic performance using receiver operating characteristic (ROC) analysis and agreement statistics. Results: Thirty-minute AOBP values were consistently higher than ABPM measurements. Mean differences were +6.59/ + 7.27 mmHg for systolic/diastolic BP versus 24-hour ABPM and +3.73/ + 5.16 mmHg versus daytime ABPM (all p < 0.001). Bland–Altman analysis showed acceptable group-level agreement but wide limits of agreement. Sensitivity ranged from 84% to 96% and specificity from 28% to 79%. ROC analysis demonstrated good discrimination (AUC 0.77–0.87). The highest agreement with overall ABPM occurred at a cut-off of ≥140/84 mmHg (κ = 0.624). Conclusions: Thirty-minute AOBP showed good discrimination for elevated ambulatory blood pressure but systematically overestimated BP relative to ABPM. It may serve as a practical screening tool, although normal AOBP values cannot reliably exclude ambulatory HTN and confirmation with 24-hour ABPM remains necessary. Central Illustration: Diagnostic Performance of 30-Minute Automated Office Blood Pressure Compared With 24-Hour Ambulatory Monitoring
- 2 November 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (11) , e0360957
Open AccessCompare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study
Background: Ambulatory blood pressure monitoring (ABPM) is the reference standard for diagnosing hypertension (HTN), but its use in routine practice remains limited because of cost, availability, and patient burden. Automated office blood pressure (AOBP) has been proposed as a practical alternative, although its performance relative to ABPM remains uncertain. Objectives: To evaluate the agreement and diagnostic performance of 30-minute AOBP compared with 24-hour ABPM and to identify optimal cut-off values for detecting ambulatory hypertension. Methods: In this prospective cohort study, 79 adults undergoing ABPM also underwent 30-minute AOBP measurement with automated readings every 5 minutes. The mean of the final six measurements was analyzed. Agreement was assessed using paired comparisons and Bland–Altman analysis. Diagnostic performance using receiver operating characteristic (ROC) analysis and agreement statistics. Results: Thirty-minute AOBP values were consistently higher than ABPM measurements. Mean differences were +6.59/ + 7.27 mmHg for systolic/diastolic BP versus 24-hour ABPM and +3.73/ + 5.16 mmHg versus daytime ABPM (all p < 0.001). Bland–Altman analysis showed acceptable group-level agreement but wide limits of agreement. Sensitivity ranged from 84% to 96% and specificity from 28% to 79%. ROC analysis demonstrated good discrimination (AUC 0.77–0.87). The highest agreement with overall ABPM occurred at a cut-off of ≥140/84 mmHg (κ = 0.624). Conclusions: Thirty-minute AOBP showed good discrimination for elevated ambulatory blood pressure but systematically overestimated BP relative to ABPM. It may serve as a practical screening tool, although normal AOBP values cannot reliably exclude ambulatory HTN and confirmation with 24-hour ABPM remains necessary. Central Illustration: Diagnostic Performance of 30-Minute Automated Office Blood Pressure Compared With 24-Hour Ambulatory Monitoring
- Open Access
- 13 August 2026
- Published by Springer Nature in BMC Research Notes
- Vol. 19 (1)
Characteristics of Wellens syndrome patients in acute coronary syndrome: a retrospective study
- 13 August 2026
- Published by Springer Nature in BMC Research Notes
- Vol. 19 (1)
Open AccessCharacteristics of Wellens syndrome patients in acute coronary syndrome: a retrospective study
- 9 April 2026
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 8 (1) , 113
Wellens Syndrome in the Modern Era: A Contemporary Review
- 9 April 2026
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 8 (1) , 113
Wellens Syndrome in the Modern Era: A Contemporary Review