Ângelo Rafael Machado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ângelo Rafael Machado has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Arnaldo César Pereira
Universidade Federal de São João del-Rei
2 shared publications - Lucas Franco Ferreira
Institute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, MG, Brazil
2 shared publications - Daniela Nunes da Silva
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
1 shared publication - Diego Leoni Franco
Chemistry Institute, Federal University of Uberlândia (UFU), Patos de Minas 38700-002, MG, Brazil
1 shared publication - Geycson Figueiredo Dias
Institute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, MG, Brazil
1 shared publication - Patrick Wander Endlich
Mucuri School of Medicine, Graduate Program in Health Sciences Federal University of Jequitinhonha and Mucuri Valleys Teófilo Otoni Brazil
1 shared publication
Latest Publications
- Open Access
- 9 June 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (6) , 132
Electrochemical Biosensors for Hormone Detection: Advances and Trends—An Update Since 2010
Hormones regulate numerous physiological processes and are essential for maintaining metabolic homeostasis. Accurate hormone quantification is crucial for the diagnosis and monitoring of endocrine and metabolic disorders. Electrochemical biosensors have recently emerged as promising platforms for hormone detection, offering simplicity, rapid response, cost-effectiveness, and high sensitivity compared to conventional techniques such as chromatography and mass spectrometry. This review summarizes the advances in electrochemical biosensors for detecting clinically relevant hormones, including cortisol, estrogen, progesterone, thyroid-stimulating hormone, parathyroid hormone, prolactin, and insulin, since 2010. Particular attention has been paid to developments in electrode modification strategies, including nanomaterials, redox enzymes, and novel recognition elements, which significantly improve the sensitivity and selectivity. These advances enable hormone detection at lower concentrations in various biological and environmental matrices. Despite these promising developments, challenges related to sensor stability, fabrication costs, and regeneration procedures limit their large-scale commercialization. Future research should focus on improving robustness, optimizing immobilization strategies, and integrating innovative materials to enhance the analytical performance. Continued collaboration among researchers, engineers, and healthcare professionals is essential. With ongoing technological progress, electrochemical biosensors are expected to play an important role in clinical diagnosis, point-of-care testing, and personalized medicine.
- 9 June 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (6) , 132
Open AccessElectrochemical Biosensors for Hormone Detection: Advances and Trends—An Update Since 2010
Hormones regulate numerous physiological processes and are essential for maintaining metabolic homeostasis. Accurate hormone quantification is crucial for the diagnosis and monitoring of endocrine and metabolic disorders. Electrochemical biosensors have recently emerged as promising platforms for hormone detection, offering simplicity, rapid response, cost-effectiveness, and high sensitivity compared to conventional techniques such as chromatography and mass spectrometry. This review summarizes the advances in electrochemical biosensors for detecting clinically relevant hormones, including cortisol, estrogen, progesterone, thyroid-stimulating hormone, parathyroid hormone, prolactin, and insulin, since 2010. Particular attention has been paid to developments in electrode modification strategies, including nanomaterials, redox enzymes, and novel recognition elements, which significantly improve the sensitivity and selectivity. These advances enable hormone detection at lower concentrations in various biological and environmental matrices. Despite these promising developments, challenges related to sensor stability, fabrication costs, and regeneration procedures limit their large-scale commercialization. Future research should focus on improving robustness, optimizing immobilization strategies, and integrating innovative materials to enhance the analytical performance. Continued collaboration among researchers, engineers, and healthcare professionals is essential. With ongoing technological progress, electrochemical biosensors are expected to play an important role in clinical diagnosis, point-of-care testing, and personalized medicine.
- 9 April 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Laser-Induced Graphene Electrodes for the Voltammetric Determination of Ciprofloxacin in Pharmaceutical and Water Samples
This study reports a laser-induced graphene (LIG) electrode as a simple platform for the determination of ciprofloxacin (CPX). LIG was fabricated by laser scribing a Kapton® polyimide tape affixed to a ceramic substrate. Under optimized conditions, phosphate buffer as supporting electrolyte (0.10 mol L⁻¹, pH 7.0), and differential pulse voltammetry (pulse amplitude 60 mV, scan rate 30 mV s⁻¹), the method delivered a linear response from 8.3 to 166.7 μmol L⁻¹, with limits of detection and quantification of 2.5 and 8.3 μmol L⁻¹, respectively. The procedure was successfully applied to a pharmaceutical formulation and river water, yielding recoveries of 92.93–110% with good precision, thereby demonstrating the robustness of the method. The proposed LIG sensor is a cost-effective and sustainable alternative for environmental and quality control monitoring of CPX.
- 9 April 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Laser-Induced Graphene Electrodes for the Voltammetric Determination of Ciprofloxacin in Pharmaceutical and Water Samples
This study reports a laser-induced graphene (LIG) electrode as a simple platform for the determination of ciprofloxacin (CPX). LIG was fabricated by laser scribing a Kapton® polyimide tape affixed to a ceramic substrate. Under optimized conditions, phosphate buffer as supporting electrolyte (0.10 mol L⁻¹, pH 7.0), and differential pulse voltammetry (pulse amplitude 60 mV, scan rate 30 mV s⁻¹), the method delivered a linear response from 8.3 to 166.7 μmol L⁻¹, with limits of detection and quantification of 2.5 and 8.3 μmol L⁻¹, respectively. The procedure was successfully applied to a pharmaceutical formulation and river water, yielding recoveries of 92.93–110% with good precision, thereby demonstrating the robustness of the method. The proposed LIG sensor is a cost-effective and sustainable alternative for environmental and quality control monitoring of CPX.