Nawid Faizi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nawid Faizi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ingeborg Stalmans
KU Leuven
1 shared publication - Jan Van Eijgen
KU Leuven
1 shared publication - Keith R. Martin
Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia
1 shared publication - Marie-Isaline Billen Moulin-Romsée
Research Group Ophthalmology, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium
1 shared publication - Nathan Mitchell Kerr
Centre for Eye Research Australia Ltd, East Melbourne, Victoria, AUSTRALIA
1 shared publication - Thomas Jacobs
UZ Leuven
1 shared publication
Latest Publications
- Open Access
- 15 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (8) , 3028
Outcomes of Ab Interno 63 µm vs. 45 µm XEN® Gel Stent in Open-Angle Glaucoma: A Five-Year Follow-Up Study
Background/Objectives: To compare the five-year efficacy and safety of the 63 µm (XEN63) vs. 45 µm (XEN45) XEN® Gel Stent in patients with open-angle glaucoma (OAG). Methods: This retrospective matched (1:1) cohort study included adults with OAG who underwent standalone ab interno implantation of the XEN63 or the XEN45 between 2014 and 2021 at a tertiary referral center in Belgium. The primary outcome was IOP at five years. The secondary outcomes included surgical success, topical medication use, postoperative hypotony, complications and interventions. Results: Thirty eyes of 30 patients (15 XEN63 and 15 XEN45) were analyzed. The baseline characteristics were comparable. At five years, the mean IOP did not differ between the XEN63 and the XEN45 (11.5 vs. 11.0 mmHg; p = 0.54). The XEN63 demonstrated higher complete success rates than the XEN45 for both the IOP < 18 mmHg (10 vs. four eyes; p = 0.016) and p = 0.003). The topical medication use was low and comparable (0.6 vs. 0.9 medications; p = 0.57). The numerical (13 vs. five eyes; p = 0.008) and symptomatic (six vs. two eyes; p = 0.2) hypotony were more frequent after the XEN63 implantation. The two eyes with XEN63 and none with XEN45 experienced clinically significant hypotony. The needling procedures and secondary glaucoma surgeries were more frequent after the XEN45. Conclusions: The XEN63 implantation was associated with higher long-term success rates and also with a higher incidence of early postoperative hypotony. These findings indicate a trade-off between efficacy and safety and suggest that careful patient selection and postoperative management are essential when considering larger lumen subconjunctival drainage devices.
- 15 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (8) , 3028
Open AccessOutcomes of Ab Interno 63 µm vs. 45 µm XEN® Gel Stent in Open-Angle Glaucoma: A Five-Year Follow-Up Study
Background/Objectives: To compare the five-year efficacy and safety of the 63 µm (XEN63) vs. 45 µm (XEN45) XEN® Gel Stent in patients with open-angle glaucoma (OAG). Methods: This retrospective matched (1:1) cohort study included adults with OAG who underwent standalone ab interno implantation of the XEN63 or the XEN45 between 2014 and 2021 at a tertiary referral center in Belgium. The primary outcome was IOP at five years. The secondary outcomes included surgical success, topical medication use, postoperative hypotony, complications and interventions. Results: Thirty eyes of 30 patients (15 XEN63 and 15 XEN45) were analyzed. The baseline characteristics were comparable. At five years, the mean IOP did not differ between the XEN63 and the XEN45 (11.5 vs. 11.0 mmHg; p = 0.54). The XEN63 demonstrated higher complete success rates than the XEN45 for both the IOP < 18 mmHg (10 vs. four eyes; p = 0.016) and p = 0.003). The topical medication use was low and comparable (0.6 vs. 0.9 medications; p = 0.57). The numerical (13 vs. five eyes; p = 0.008) and symptomatic (six vs. two eyes; p = 0.2) hypotony were more frequent after the XEN63 implantation. The two eyes with XEN63 and none with XEN45 experienced clinically significant hypotony. The needling procedures and secondary glaucoma surgeries were more frequent after the XEN45. Conclusions: The XEN63 implantation was associated with higher long-term success rates and also with a higher incidence of early postoperative hypotony. These findings indicate a trade-off between efficacy and safety and suggest that careful patient selection and postoperative management are essential when considering larger lumen subconjunctival drainage devices.