Atreyee Acharya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Atreyee Acharya has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Arthur Baroni
Center for Photon Science Paul Scherrer Institute (PSI) Villigen Switzerland
1 shared publication - Irene Rodriguez-Fernandez
PSI Center for Photon Science, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
1 shared publication - Mads Carlsen
Center for Photon Science Paul Scherrer Institute (PSI) Villigen Switzerland
1 shared publication - Marianne Liebi
Department of Physics, Chalmers University of Technology, Gothenburg, Sweden
1 shared publication
Latest Publications
- Open Access
- 14 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 632-648
Effect of soft tissue sample preparation techniques for scanning small-angle X-ray scattering experiments
Scanning small-angle X-ray scattering (sSAXS) has found multiple applications as a technique to probe the nanostructure in soft tissues and pathologies thereof. However, fresh tissue is fragile and prone to the quick onset of decomposition and autolysis. It lacks the firmness required for uniform and thin sectioning, resulting in the loss of 2D resolution offered by focused X-ray beams, because the signal would be integrated through thick and/or irregular sections. Tissue processing, that includes fixation and embedding, is used to mitigate these issues but can by itself introduce structural changes in the tissues and impede the correct interpretation of sSAXS data. Here the extent of these structural changes in the SAXS signal caused by common tissue preservation methods on the example of skeletal muscle tissue, consisting of both muscle and surrounding connective tissue, was studied. This can guide an informed choice of preservation method tailored for specific experimental requirements. While some techniques performed better than others, all tissue-processing methods induced structural changes to a certain degree. The choice of preservation method is therefore a balance between sectioning requirements and type of tissue used, as well as targeted structural information.
- 14 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 632-648
Open AccessEffect of soft tissue sample preparation techniques for scanning small-angle X-ray scattering experiments
Scanning small-angle X-ray scattering (sSAXS) has found multiple applications as a technique to probe the nanostructure in soft tissues and pathologies thereof. However, fresh tissue is fragile and prone to the quick onset of decomposition and autolysis. It lacks the firmness required for uniform and thin sectioning, resulting in the loss of 2D resolution offered by focused X-ray beams, because the signal would be integrated through thick and/or irregular sections. Tissue processing, that includes fixation and embedding, is used to mitigate these issues but can by itself introduce structural changes in the tissues and impede the correct interpretation of sSAXS data. Here the extent of these structural changes in the SAXS signal caused by common tissue preservation methods on the example of skeletal muscle tissue, consisting of both muscle and surrounding connective tissue, was studied. This can guide an informed choice of preservation method tailored for specific experimental requirements. While some techniques performed better than others, all tissue-processing methods induced structural changes to a certain degree. The choice of preservation method is therefore a balance between sectioning requirements and type of tissue used, as well as targeted structural information.