JRJakob Richter

Jakob Richter

*This is an algorithmically generated author record based on publicly available information.

Jakob Richter has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Nebulizer Breath-Guiding on Breathing Patterns and Lung Deposition

    by Benjamin Heine, Uwe Schuschnig, Jakob Richter, Andreas Liebl, Lea Botermann, Gesa Bräunlich, Nicolas Schwenck, Maximilian J. Grill, Michael Hahn

    Background: Efficient aerosol therapy depends on both device performance and inhalation technique. Breath-triggered vibrating mesh nebulizers reduce drug loss by generating aerosol only during inspiration but may prolong treatment. Guiding patients toward slow, deep breathing could improve lung deposition and shorten nebulization time, yet quantitative evidence, particularly across disease groups, remains limited. Objective: To assess how integrated breath-guiding features influence breathing behavior, lung deposition, and user perception in healthy adults and in patients with obstructive or restrictive lung disease. Methods: Sixty-four participants inhaled through three nebulizer configurations: a low-resistance reference (eFlow OS) and two versions of the eFlow Integrated featuring direction-dependent resistance and multimodal feedback, tested with or without a breath-guiding app. Flow signals from multiple breaths were analyzed to determine phase-averaged breathing parameters. Device effects were evaluated by ANOVA. Representative breathing patterns and unsteady aerosol characteristics were input to a validated whole-lung in silico model to estimate deposition. User experience was assessed by questionnaire. Results: Breath-guiding consistently altered inhalation behavior. Peak inspiratory flow decreased by ∼20%, the I/E ratio increased by >15%, and with the breath guide app, tidal volume (+40%) and breath duration (+47%) increased. These effects were similar across disease groups. In silico simulations showed improved delivery with guided inhalation: lung drug deposition rate increased by 3.7% and 15.5%, and alveolar deposited mass fraction rose by 66% and 76% versus the reference. The breath guide app further shifted deposition from extrathoracic to thoracic and alveolar regions and reduced exhalation losses (–14%). Most participants (88%) were satisfied or very satisfied, citing pleasant resistance and helpful app guidance. Conclusion: Breath-guiding features and digital coaching reliably promote slower, deeper breathing, leading to greater lung and alveolar deposition and shorter expected nebulization times. High user acceptance underscores the clinical potential of patient-centric, guided inhalation in optimizing aerosol therapy.

  • Open Access

    In silico high-resolution whole lung model to predict the locally delivered dose of inhaled drugs

    by Maximilian J. Grill, Jonas Biehler, Karl-Robert Wichmann, Jakob Richter, Maximilian Rixner, David Rudlstorfer, Marie Brei, Julian L. Rehfeldt, Jakob A. Hofer, Joshua Bügel, et al.

    The big crux with drug delivery to human lungs is that the delivered dose at the local site of action is unpredictable and very difficult to measure, even a posteriori. It is highly subject-specific as it depends on lung morphology, disease, breathing, and aerosol characteristics. Given these challenges, computational approaches have shown potential, but have so far failed due to fundamental methodical limitations. We present and validate a novel in silico model that enables the subject-specific prediction of local aerosol deposition throughout the entire lung. Its unprecedented spatiotemporal resolution allows to track each aerosol particle anytime during the breathing cycle, anywhere in the complete system of conducting airways and the alveolar region. Predictions are shown to be in excellent agreement with in vivo SPECT/CT data for a healthy human cohort. We further showcase the model's capabilities to represent strong heterogeneities in diseased lungs by studying an IPF patient. Finally, high computational efficiency and automated model generation and calibration ensure readiness to be applied at scale. We envision our method not only to improve inhalation therapies by informing and accelerating all stages of (pre-)clinical drug and device development, but also as a more-than-equivalent alternative to nuclear aerosol dosimetry imaging of the lungs.