LKLeon Kopka

Leon Kopka

*This is an algorithmically generated author record based on publicly available information.

Leon Kopka has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An automated hierarchical workflow for static and dynamic district heating simulation with UESgraphs v2.0.0: A case study from a German living lab project

    by Rahul Mohandasan Karuvingal, Kai Droste, Leon Kopka, Arkadi Butenko, Kai Derzsi, Jonas Klingebiel, Dirk Müller

  • Open Access

    An Automated Hierarchical Workflow for Static and Dynamic District Heating Simulation with UESgraphs v2.0.0: A Case Study from a German Living Lab Project

    by Rahul Karuvingal, Kai Droste, Leon Kopka, Arkadi Butenko, Kai Derzsi, Jonas Klingebiel, Dirk Müller

    Transitioning to fourth and fifth Generation District Heating and Cooling (DHC) systems is vital for urban decarbonization but is impeded by a disconnect between static spatial planning and dynamic physical simulation. This ``modeling gap'' forces engineers into labor-intensive, manual workflows, hindering iterative design. This study introduces a workflow utilizing UESgraphs v2.0.0, a fully automated, open-source Python framework that generates simulation-ready digital twins directly from raw GIS data. The methodology integrates a graph-based topology generator with two simulation engines: Pandapipes for rapid quasi-static thermo-hydraulic simulation and the Modelica AixLib package for high-fidelity dynamic analysis. The workflow is validated on a district from the TransUrban.NRW living lab project in Germany, analyzing the expansion from four to forty-three buildings. Findings indicate the pre-processing effectively adapted the topology from a simple tree to a resilient multi-source ring grid. Comparing both engines revealed a critical trade-off between computational efficiency and transient physical accuracy. The static engine completed the 43-building annual simulation in 13 minutes using under 0.5 GB RAM. Conversely, the dynamic model successfully captured essential thermal inertia and transient behaviors but required over 7.4 hours—a 34-fold increase—and 13 GB RAM for initialization. Consequently, a hierarchical workflow leveraging static tools for rapid topological sizing and dynamic models for transient validation is essential. This open-source approach reduces modeling barriers, ensuring transparent, scalable, and reproducible district energy planning.