Haoran Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haoran Zhou has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chenxin Zhang
College of Telecommunication and Information Engineering, Nanjing University of Posts and Telecommunications 2 , Nanjing
2 shared publications - Guanxiang Du
Nanjing University of Posts and Telecommunications
2 shared publications - Haoyu Li
Portland Institute, Nanjing University of Posts and Telecommunications 1 , Nanjing
2 shared publications Baihao Zhou
College of Telecommunication and Information Engineering, Nanjing University of Posts and Telecommunications 2 , Nanjing
1 shared publication- Guo-Bin Chen
School of Mechanical and Electrical Engineering, Suqian College, Suqian, China
1 shared publication - Honghao Chen
College of Telecommunication and Information Engineering, Nanjing University of Posts and Telecommunications 2 , Nanjing
1 shared publication
Latest Publications
- 17 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (7)
Bias field-free resolution of symmetry-induced ambiguity in ensemble NV magnetometry via orthogonal rotations
Ensemble nitrogen-vacancy (NV) centers enable vector magnetic-field sensing, but the tetrahedral symmetry of the four NV orientations renders the field direction intrinsically ambiguous in ensemble optically detected magnetic resonance (ODMR) measurements. For a fixed field magnitude, up to 48 symmetry-related orientations can produce identical spectra. Here, we introduce a double-rotation protocol that resolves this symmetry-induced ambiguity without applying bias magnetic fields or other symmetry-breaking perturbations. By comparing reconstructed field directions obtained from ODMR spectra before and after two controlled rigid rotations about orthogonal axes, the protocol geometrically restricts the solution space to a unique angular region up to the intrinsic inversion symmetry B↔−B. The method is purely geometric and independent of the specific magnetic-field reconstruction algorithm. It is particularly suited for moderate magnetic fields (from a few millitesla to a few tens of millitesla) and for experimental situations where additional bias fields would perturb the magnetic system under investigation.
- 17 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (7)
Bias field-free resolution of symmetry-induced ambiguity in ensemble NV magnetometry via orthogonal rotations
Ensemble nitrogen-vacancy (NV) centers enable vector magnetic-field sensing, but the tetrahedral symmetry of the four NV orientations renders the field direction intrinsically ambiguous in ensemble optically detected magnetic resonance (ODMR) measurements. For a fixed field magnitude, up to 48 symmetry-related orientations can produce identical spectra. Here, we introduce a double-rotation protocol that resolves this symmetry-induced ambiguity without applying bias magnetic fields or other symmetry-breaking perturbations. By comparing reconstructed field directions obtained from ODMR spectra before and after two controlled rigid rotations about orthogonal axes, the protocol geometrically restricts the solution space to a unique angular region up to the intrinsic inversion symmetry B↔−B. The method is purely geometric and independent of the specific magnetic-field reconstruction algorithm. It is particularly suited for moderate magnetic fields (from a few millitesla to a few tens of millitesla) and for experimental situations where additional bias fields would perturb the magnetic system under investigation.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Scalar Magnetic Field Measurement Based on Nitrogen-Vacancy Centers in Diamond
Nitrogen-vacancy (NV) centers in diamond have emerged as promising platforms for quantum magnetic field measurement. Conventional NV-based magnetometry requires precise alignment with field orientation, fundamentally limiting its applicability in unconstrained measurement scenarios. In this article, we present an orientation-independent scalar magnetometry technique exploiting the zero-field splitting (ZFS) characteristics of NV ensembles under optically detected magnetic resonance (ODMR) with high stability. We demonstrate a scalar magnetometry system capable of wide-range measurement from 2 mT to 45 mT. By employing a strategy that combines segmented measurement with independent fitting of individual ODMR spectral lines, the system achieves enhanced measurement stability with significantly improved measurement effciency. A field-programmable gate array (FPGA)-based pulse generating and data acquisition system and a Python automated analysis program are implemented in this work. Experimental validation demonstrates the measured magnitude has the maximum ± 0.461 % deviation from the reference magnetic field by a standard field generator, with nonlinearity error of 0.0952 % in the range mentioned above and measurement noise figure of 359.58 nT/ √ Hz. This orientation-insensitive approach establishes a new paradigm for non-invasive magnetic measurements, particularly suitable for biomedical diagnostics requiring anatomical adaptability and industrial inspection of complex component geometries.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Scalar Magnetic Field Measurement Based on Nitrogen-Vacancy Centers in Diamond
Nitrogen-vacancy (NV) centers in diamond have emerged as promising platforms for quantum magnetic field measurement. Conventional NV-based magnetometry requires precise alignment with field orientation, fundamentally limiting its applicability in unconstrained measurement scenarios. In this article, we present an orientation-independent scalar magnetometry technique exploiting the zero-field splitting (ZFS) characteristics of NV ensembles under optically detected magnetic resonance (ODMR) with high stability. We demonstrate a scalar magnetometry system capable of wide-range measurement from 2 mT to 45 mT. By employing a strategy that combines segmented measurement with independent fitting of individual ODMR spectral lines, the system achieves enhanced measurement stability with significantly improved measurement effciency. A field-programmable gate array (FPGA)-based pulse generating and data acquisition system and a Python automated analysis program are implemented in this work. Experimental validation demonstrates the measured magnitude has the maximum ± 0.461 % deviation from the reference magnetic field by a standard field generator, with nonlinearity error of 0.0952 % in the range mentioned above and measurement noise figure of 359.58 nT/ √ Hz. This orientation-insensitive approach establishes a new paradigm for non-invasive magnetic measurements, particularly suitable for biomedical diagnostics requiring anatomical adaptability and industrial inspection of complex component geometries.