ZCZhanyuan Cao

Zhanyuan Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhanyuan Cao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic Reading of Analog Pointer Meters Based on YOLO Localization and Template-Calibrated Angle-to-Value Mapping

    by Shijie Zhang, Yu’Ang Qin, Hui Zhang, Jilong Wang, Xiang Wu, Zhanyuan Cao, Mengkun Zhang

    Automatic reading of analog pointer meters is affected by complex backgrounds, illumination changes, and camera viewpoints. This study implements and evaluates a template-calibrated reading procedure that integrates established detection and image-processing components for fixed-layout analog instruments with instrument-specific pointer segmentation. YOLO localizes the meter, and the detected region is aligned with a manually calibrated template. Illumination-adaptive color segmentation and geometric processing estimate the pointer angle, which is converted to a reading by interpolation between adjacent calibrated angles. Compared with endpoint-based linear mapping, this procedure uses intermediate scale information to represent local angle–value relationships. Relative to approaches requiring dedicated pointer-segmentation or reading-regression networks, its reading stage avoids pixel-level pointer annotations and dedicated network training, while requiring manual template calibration and suitable pointer-segmentation settings. On the 58-image independent real-scene detection test set, YOLO achieved an mAP@0.5 of 99.50% and an mAP@0.5:0.95 of 77.72%. On 58 still images of a single 0–1.6 MPa pressure gauge, the method achieved a mean absolute error (MAE) of 0.0095 MPa, a root-mean-square error of 0.0135 MPa, and a maximum absolute error of 0.0408 MPa relative to manual reference readings. Image-level predictions were matched to the means of 16 supplied manual readings per image. These errors quantify agreement with those means; the variability and unvalidated uncertainty of the manual references preclude interpreting the MAE as equivalent absolute pressure-measurement accuracy. Supplementary evaluation on 26 images of a second pressure gauge and 28 images of a thermometer yielded scale-normalized MAEs of 0.1870% and 0.0787%, respectively, after instrument-specific calibration and segmentation configuration. These evaluation images informed segmentation-parameter selection; the results therefore illustrate reuse after configuration, without establishing generalization to unseen instruments or images.

  • Open Access

    Particle Swarm Optimization Parameter Model Predictive Control Based on a Fully Actuated System Approach

    by Shijie Zhang, Zhanyuan Cao, Mingzhe Hou, Hui Zhang, Jilong Wang, Yu’ANg Qin

    To address adaptive trajectory control under external disturbances and state constraints, this paper proposes a PSO–FAS–MPC control framework that integrates a fully actuated system, model predictive control, and particle swarm optimization. FAS is used to linearize the system and simplify the MPC design; MPC optimizes the tracking performance under constraints, while PSO tunes the MPC parameters to enhance the adaptability to diverse scenarios. Comprehensive experimental validation on both 2‐DOF planar and 6‐DOF spatial manipulators demonstrates that the proposed framework reduces convergence time by up to 87% and tracking error by over 40% compared to conventional methods, while achieving significantly smoother torque profiles. These results validate the enhanced adaptability, scalability, and robustness of the integrated approach in handling complex nonlinear dynamics under various constraints and disturbances.