Maximilian Philip Wessendorf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maximilian Philip Wessendorf has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Maurice Stephan Michel
Department of Urology Mannheim University Medical Centre Mannheim Germany
2 shared publicationsNektarios Winter
German Cancer Research Centre (Deutsches Krebsforschungszentrum [DKFZ]) Heidelberg Intelligent Systems and Robotics in Urology Heidelberg Germany
2 shared publicationsAlexander Studier‐Fischer
German Cancer Research Centre (Deutsches Krebsforschungszentrum [DKFZ]) Heidelberg Intelligent Systems and Robotics in Urology Heidelberg Germany
1 shared publicationAntonia Thiele
German Cancer Research Center (DKFZ) Heidelberg, Intelligent Systems and Robotics in Urology, Heidelberg, Germany
1 shared publication- Balint Kovacs
Deutsches Krebsforschungszentrum
1 shared publication - Bruno Reible
Institute for Pathology, Mannheim University Medical Center, Mannheim, Germany
1 shared publication
Latest Publications
- Open Access
- 18 June 2026
- Published by Wiley in BJU International
- Vol. 138 (4) , 630-639
Structured micro‐ultrasonography training improves prostate cancer detection and management decisions
Objective: To evaluate whether a structured 2‐day micro‐ultrasonography (microUS) training curriculum improves diagnostic performance and management decisions for clinically significant prostate cancer (csPCa) detection in novice readers. Subjects and Methods: A total of 20 participants with limited microUS experience completed the Mannheim Micro‐Ultrasound Curriculum, comprising didactic modules, supervised case interpretation, and 85 reference cases. Pre‐ and post‐training performance was assessed on a fixed, biopsy confirmed test set of 100 cases (50 csPCa confirmed on radical prostatectomy, 50 biopsy negative). Each participant interpreted 10 randomised cases per timepoint, with no case assessed twice per reader and each case being assessed once before and after training in each training session. The primary endpoint was change in cohort‐level accuracy for csPCa detection; secondary endpoints included sensitivity, specificity, predictive values, area under the receiver operating characteristic curve (AUC), Prostate Risk Identification using microUS (PRI‐MUS) performance, and management recommendations. Mixed‐effects models were applied as a robustness analysis. Results: Training significantly improved pooled cohort level accuracy from 50.5% (95% confidence interval [CI] 43.4–57.6%) to 64.5% (95% CI 57.4–71.1%; P = 0.006), sensitivity from 70.0% (95% CI 60.0–78.8%) to 92.0% (95% CI 84.8–96.5%; P = 0.001), and negative predictive value from 50.8% (95% CI 37.7–63.9%) to 82.2% (95% CI 67.9–92.0%; P = 0.001), whereas specificity did not increase significantly (31.0% vs 37.0%; P = 0.46). The AUC for the overall subjective risk score rose from 0.53 (95% CI 0.45–0.61) to 0.70 (95% CI 0.63–0.77; P = 0.002). Mixed‐effects modelling confirmed a significant training effect (odds ratio 2.13, 95% CI 1.20–3.79; P = 0.01), reproducible across two independent sessions. PRI‐MUS scoring improvements were not statistically significant. Overall decision correctness improved from 67% to 83% ( P = 0.001), with poor‐quality decisions decreasing from 33% to 17%. Conclusion: Structured image‐based microUS training significantly improved cohort‐level diagnostic performance and management decisions in novice readers in a controlled reader‐study. These findings support structured training and quality assurance before independent clinical implementation of microUS.
- 18 June 2026
- Published by Wiley in BJU International
- Vol. 138 (4) , 630-639
Open AccessStructured micro‐ultrasonography training improves prostate cancer detection and management decisions
Objective: To evaluate whether a structured 2‐day micro‐ultrasonography (microUS) training curriculum improves diagnostic performance and management decisions for clinically significant prostate cancer (csPCa) detection in novice readers. Subjects and Methods: A total of 20 participants with limited microUS experience completed the Mannheim Micro‐Ultrasound Curriculum, comprising didactic modules, supervised case interpretation, and 85 reference cases. Pre‐ and post‐training performance was assessed on a fixed, biopsy confirmed test set of 100 cases (50 csPCa confirmed on radical prostatectomy, 50 biopsy negative). Each participant interpreted 10 randomised cases per timepoint, with no case assessed twice per reader and each case being assessed once before and after training in each training session. The primary endpoint was change in cohort‐level accuracy for csPCa detection; secondary endpoints included sensitivity, specificity, predictive values, area under the receiver operating characteristic curve (AUC), Prostate Risk Identification using microUS (PRI‐MUS) performance, and management recommendations. Mixed‐effects models were applied as a robustness analysis. Results: Training significantly improved pooled cohort level accuracy from 50.5% (95% confidence interval [CI] 43.4–57.6%) to 64.5% (95% CI 57.4–71.1%; P = 0.006), sensitivity from 70.0% (95% CI 60.0–78.8%) to 92.0% (95% CI 84.8–96.5%; P = 0.001), and negative predictive value from 50.8% (95% CI 37.7–63.9%) to 82.2% (95% CI 67.9–92.0%; P = 0.001), whereas specificity did not increase significantly (31.0% vs 37.0%; P = 0.46). The AUC for the overall subjective risk score rose from 0.53 (95% CI 0.45–0.61) to 0.70 (95% CI 0.63–0.77; P = 0.002). Mixed‐effects modelling confirmed a significant training effect (odds ratio 2.13, 95% CI 1.20–3.79; P = 0.01), reproducible across two independent sessions. PRI‐MUS scoring improvements were not statistically significant. Overall decision correctness improved from 67% to 83% ( P = 0.001), with poor‐quality decisions decreasing from 33% to 17%. Conclusion: Structured image‐based microUS training significantly improved cohort‐level diagnostic performance and management decisions in novice readers in a controlled reader‐study. These findings support structured training and quality assurance before independent clinical implementation of microUS.
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in JU Open Plus
- Vol. 4 (4)
Artificial Intelligence–Assisted Prostate Cancer Diagnosis on Transrectal Microultrasound—A Pilot Study for the DeepTRUS Model
Purpose: Microultrasound might serve as a viable alternative to MRI for initial prostate cancer detection. This study developed a deep learning model to detect clinically significant prostate cancer (csPCa) on microultrasound and evaluated its impact on diagnostic performance among novice readers. Materials and Methods: One hundred microultrasound sweeps (50 csPCa, 50 benign) were used to train a deep learning model. Model performance was assessed using the area under the receiver operating characteristics curve (AUC) and Dice similarity coefficient (DSC). In an independent test set (25 csPCa, 25 benign), 5 novice readers each evaluated 2 unique sets of 10 sweeps before and after a structured microultrasound training. In both sessions, they first reviewed sweeps unaided and then with algorithm-generated heatmaps. Results: On the training set, DeepTRUS achieved an AUC of 0.687 (95% confidence interval 0.583-0.791) and a DSC of 0.30 (0.21-0.39). In the test set, reader AUC improved from 0.459 (0.294-0.624) to 0.556 (0.394-0.718) before training, and from 0.610 (0.452-0.767) to 0.782 (0.656-0.908) after training, with DeepTRUS assistance. Sensitivity increased from 60% to 72% pretraining and from 80% to 88% posttraining. The interaction between training and DeepTRUS assistance was significant ( P = .006). Conclusions: This pilot study demonstrates the feasibility of training deep learning models on microultrasound data and their potential to enhance diagnostic performance when combined with reader training. The findings provide proof of concept for artificial intelligence–assisted microultrasound interpretation and inform the design of larger validation studies.
- 1 April 2026
- Published by Wolters Kluwer Health in JU Open Plus
- Vol. 4 (4)
Open AccessArtificial Intelligence–Assisted Prostate Cancer Diagnosis on Transrectal Microultrasound—A Pilot Study for the DeepTRUS Model
Purpose: Microultrasound might serve as a viable alternative to MRI for initial prostate cancer detection. This study developed a deep learning model to detect clinically significant prostate cancer (csPCa) on microultrasound and evaluated its impact on diagnostic performance among novice readers. Materials and Methods: One hundred microultrasound sweeps (50 csPCa, 50 benign) were used to train a deep learning model. Model performance was assessed using the area under the receiver operating characteristics curve (AUC) and Dice similarity coefficient (DSC). In an independent test set (25 csPCa, 25 benign), 5 novice readers each evaluated 2 unique sets of 10 sweeps before and after a structured microultrasound training. In both sessions, they first reviewed sweeps unaided and then with algorithm-generated heatmaps. Results: On the training set, DeepTRUS achieved an AUC of 0.687 (95% confidence interval 0.583-0.791) and a DSC of 0.30 (0.21-0.39). In the test set, reader AUC improved from 0.459 (0.294-0.624) to 0.556 (0.394-0.718) before training, and from 0.610 (0.452-0.767) to 0.782 (0.656-0.908) after training, with DeepTRUS assistance. Sensitivity increased from 60% to 72% pretraining and from 80% to 88% posttraining. The interaction between training and DeepTRUS assistance was significant ( P = .006). Conclusions: This pilot study demonstrates the feasibility of training deep learning models on microultrasound data and their potential to enhance diagnostic performance when combined with reader training. The findings provide proof of concept for artificial intelligence–assisted microultrasound interpretation and inform the design of larger validation studies.