Jiangyifei Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiangyifei Zhu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Justin Chan
Carnegie Mellon University, Pittsburgh, USA
4 shared publications - Swarun Kumar
Carnegie Mellon University, Pittsburgh, USA
3 shared publications - Tao Qiang
Shanghai Jiao Tong University (SJTU)
2 shared publications Akarsh Prabhakara
Department of Computer Sciences, University of Wisconsin-Madison, Madison, WI, USA
1 shared publication- Clara Palacios-Castrillo
Electrical and Computer Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
1 shared publication - Duc Nguyen Tien Vu
Signal Processing Lab, Michigan State University, East Lansing, Michigan, USA and Semantic Signals Lab, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
1 shared publication
Latest Publications
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1774-1776
Demo: PolyPulse: Interactive mmWave Sensing of Vital Signs and Heart-to-Wrist Pulse Transit Time
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1774-1776
Open AccessDemo: PolyPulse: Interactive mmWave Sensing of Vital Signs and Heart-to-Wrist Pulse Transit Time
- Open Access
- 25 May 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Measuring multi-site pulse transit time with an AI-enabled mmWave radar
Pulse Transit Time (PTT) is a measure of arterial stiffness and a physiological marker associated with cardiovascular function, with an inverse relationship to diastolic blood pressure (DBP). We present an AI-enabled mmWave system for contactless multi-site PTT measurement using a single radar. By leveraging radar beamforming and deep learning algorithms our system simultaneously measures PTT and estimates diastolic blood pressure at multiple sites. The system was evaluated across three physiological pathways - heart-to-radial artery, heart-to-carotid artery, and mastoid area-to-radial artery - achieving correlation coefficients of 0.75-0.86 compared to contact-based reference sensors for measuring PTT. Furthermore, the system demonstrated correlation coefficients of 0.90-0.91 for estimating DBP, and achieved a mean error of -0.62-0.06 mmHg and standard deviation of 4.54-5.20 mmHg, meeting the FDA's AAMI guidelines for non-invasive blood pressure monitors. These results suggest that our proposed system has the potential to provide a non-invasive measure of cardiovascular health across multiple regions of the body.
- 25 May 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessMeasuring multi-site pulse transit time with an AI-enabled mmWave radar
Pulse Transit Time (PTT) is a measure of arterial stiffness and a physiological marker associated with cardiovascular function, with an inverse relationship to diastolic blood pressure (DBP). We present an AI-enabled mmWave system for contactless multi-site PTT measurement using a single radar. By leveraging radar beamforming and deep learning algorithms our system simultaneously measures PTT and estimates diastolic blood pressure at multiple sites. The system was evaluated across three physiological pathways - heart-to-radial artery, heart-to-carotid artery, and mastoid area-to-radial artery - achieving correlation coefficients of 0.75-0.86 compared to contact-based reference sensors for measuring PTT. Furthermore, the system demonstrated correlation coefficients of 0.90-0.91 for estimating DBP, and achieved a mean error of -0.62-0.06 mmHg and standard deviation of 4.54-5.20 mmHg, meeting the FDA's AAMI guidelines for non-invasive blood pressure monitors. These results suggest that our proposed system has the potential to provide a non-invasive measure of cardiovascular health across multiple regions of the body.
- Open Access
- 10 May 2026
- Published by Association for Computing Machinery (ACM)
- p. 274-290
GigaFlex: Contactless Monitoring of Muscle Vibrations During Exercise with a Chaos-Inspired Radar
- 10 May 2026
- Published by Association for Computing Machinery (ACM)
- p. 274-290
Open AccessGigaFlex: Contactless Monitoring of Muscle Vibrations During Exercise with a Chaos-Inspired Radar
- Open Access
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-25
LubDubDecoder: Bringing Micro-Mechanical Cardiac Monitoring to Hearables
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-25
Open AccessLubDubDecoder: Bringing Micro-Mechanical Cardiac Monitoring to Hearables