PHPaul David Hägele

Paul David Hägele

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul David Hägele has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature-Sensitive Paints and Thermochromic Liquid Crystals—A Direct Comparison for Heat Transfer Measurements

    by Marvin Tigre Larschow, Paul David Hägele, Kai Michalek, Rico Poser

    The number of suitable techniques for spatially resolved measurements of wall temperatures in internal flows is limited. Thermography using thermochromic liquid crystals (TLCs) is an established method that relies on a surface colour change to measure temperatures within a narrow band. Temperature-sensitive paints (TSP), by contrast, provide continuous temperature distributions over a wider temperature range through temperature-dependent luminescence intensity. While TLCs exhibit a lower absolute measurement uncertainty within their calibrated temperature range, TSPs allow the surface temperature to be measured continuously throughout the test period. In this work, a single-layer TLC configuration (sTLC), a multilayer TLC configuration (mTLC), and TSP are applied in three ribbed subchannels, enabling a direct technique-specific comparison under equal conditions and simultaneous evaluation. The time-dependent surface temperatures are evaluated using a transient semi-infinite wall (SIW) approach adapted to each technique. For the investigated range, the geometric mean heat transfer coefficient (HTC) differs by approximately 4% between sTLC and mTLC and by approximately 13% between sTLC and TSP. Larger local deviations are confined to the immediate vicinity of the high-gradient flank, where TSP yields a lower peak HTC and a higher HTC on the adjacent lower-gradient side than the TLC reference. Lateral heat conduction within the substrate is discussed as a possible cause. The measured temporal surface-temperature evolution was also compared with the analytical model. Good agreement is obtained in regions with high HTC, whereas a temperature plateau is observed in the TSP measurements in regions with low HTC. Finally, Monte Carlo simulations are demonstrated to estimate the measurement uncertainty of all evaluated techniques.

  • Open Access

    A Noise-Resistant Reformulation of Duhamel's Principle for Discrete Heat Transfer Evaluations

    by Paul David Hägele, Rico Poser

    This paper presents a systematic analysis of different approaches to apply Duhamel's principle to the discrete evaluation of transient heat transfer problems. The focus is on the evaluation of temperature responses under arbitrary, time-dependent boundary conditions addressing the limitations of classical instantaneous step-change assumptions. An exponentially decaying temperature profile is adopted to model realistic heating scenarios with temperature data affected by noise. Numerical integration techniques are compared with a novel stepwise partial integration (SPI) approach. The SPI method avoids numerical differentiation of noisy temperature measurements, which enhances stability and accuracy. The superior accuracy and robustness of SPI under noisy measurement conditions make it particularly well-suited for practical heat transfer analysis. This is demonstrated through an exemplary generic case study of the semi-infinite wall method using thermochromic liquid crystal (TLC) measurements.


  • Open Access

    Advances in the Analysis of Transient Heat Transfer Experiments Using Multiple Thermochromic Liquid Crystals

    by Paul David Hägele, Verena Schefthaler, David Gutiérrez de Arcos, Christian Waidmann, Rico Poser

    Transient heat transfer experiments that employ thermochromic liquid crystals (TLCs) provide high‐resolution surface‐temperature data but are hampered by noisy intensity signals, non‐ideal fluid‐temperature steps, and the challenge of resolving multiple TLC responses at pixel level. In this paper we introduce a fully automated analysis framework that (i) smooths and baseline‐corrects raw video data with a Whittaker‐algorithm whose regularisation parameter is explicitly linked to the signal density, (ii) identifies multiple intensity peaks per pixel via interval‐wise detection, and (iii) evaluates the local convective heat transfer coefficient using a stepwise‐partial‐integration (SPI) formulation of Duhamel’s principle. For each pixel, the heat transfer coefficient is determined for each individual TLC indication; the final value is formed by an inverse‐variance weighted average, guaranteeing that the most reliable indication dominates.The methodology is applied to a rotating two-pass cooling channel coated with a stack of two different narrow‐band TLC layers. Compared to conventional analysis using semi-infinite walls, the proposed workflow significantly improves the standard method by automatically detecting the peaks of multiple narrow-band TLCs. To illustrate the benefits of multiple TLCs, the additional information is used in this work to reduce the measurement uncertainty of the experiments. This is feasible because the selection of the optimal indication temperature for the TLCs depends on the heat transfer coefficient and the driving temperature difference at each individual point. Consequently, the results are evaluated post-experiment and weighted according to their respective standard deviations. This entire workflow enables multi-parameter analyses to be carried out in order to determine further variables from single experiments.